An Isolated Ring Finger Metacarpal Shaft Fracture? – Beware An Associated Little Finger Carpometacarpal Joint Dislocation

2004 ◽  
Vol 29 (6) ◽  
pp. 629-631 ◽  
Author(s):  
ALPHONSUS K. S. CHONG ◽  
WINSTON Y. C. CHEW

Dislocations of the ulnar carpometacarpal joint are easily missed because of a low index of suspicion as well as their subtle clinical and radiological features. Often, the presence of a more obvious adjacent injury also draws attention away from the carpometacarpal joint. Two cases of ring finger metacarpal shaft fractures with associated little finger carpometacarpal joint dislocations are presented. In both cases, the metacarpal fractures were diagnosed but the carpometacarpal joint dislocations were initially overlooked. The presence of an apparently isolated ring finger metacarpal fracture due to an indirect force should raise the possibility of an associated carpometacarpal joint injury.

2004 ◽  
Vol 29 (5) ◽  
pp. 449-452 ◽  
Author(s):  
GREGORY I. BAIN ◽  
P.M. RAGHAVAN UNNI ◽  
JANAK A. MEHTA ◽  
MICHAEL H.A. EAMES

Five patients with localized little finger carpometacarpal arthritis were treated by excision of the little finger metacarpal base and arthrodesis of the little and ring metacarpals. A dorsal periosteal/capsular flap was used as an interposition graft. All patients achieved significant pain relief, good cosmesis and satisfactory grip strength. All returned to activities of daily living. This procedure, the Dubert procedure, is indicated for localized pathology of the hamate-little finger metacarpal joint. It has theoretical advantages over arthrodesis and resection or interposition arthroplasty as it preserves little finger length, rotation and alignment and maintains some mobility of the transverse carpal arch and the little finger ray.


2020 ◽  
Vol 23 (3) ◽  
pp. 159-165
Author(s):  
Jeung Yeol Jeong ◽  
Yong-Min Chun

Acromioclavicular (AC) joint dislocations account for about 9% of shoulder injuries. Among them, acute high-grade injury following high-energy trauma accounts for a large proportion of patients requiring surgical treatment. However, there is no gold standard procedure for operative treatment of acute high-grade AC joint injury, and several different procedures have been used for this purpose in clinical practice. This review article summarizes the most recent and relevant surgical options for acute high-grade AC joint dislocation patients and the outcomes of each treatment type.


2012 ◽  
Vol 23 (8) ◽  
pp. 883-887 ◽  
Author(s):  
Soo-Hong Han ◽  
Seung-Yong Rhee ◽  
Soon-Chul Lee ◽  
Seung-Chul Han ◽  
Yoon-Sik Cha

Author(s):  
Siu Cheong Jeffrey Justin Koo ◽  
Henry Pang ◽  
Pak Cheong Ho

Abstract Background Fifth carpometacarpal joint (CMCJ) fracture dislocation is a relatively rare injury and most will require operative treatment because of its unstable nature. Improper reduction and fixation lead to joint surface destruction, pain, and reduced grasping power. Intra-articular fragment reduction is often obscured by dorsally displaced ulnar fragment. Therefore, fifth CMCJ arthroscopy can be advantageous in assisting intra-articular fragment reduction. However, there is no detailed description of the portal landmarks or portals' relationship with adjacent important structures in the literature. Purposes To explore the feasibility and safety of fifth CMCJ arthroscopy, locations of the portals are examined in cadaveric hand specimens. Their proximity to important anatomical structures such as dorsal cutaneous branch of ulnar nerve (DCBUN), ring finger and little finger extensor digitorum communis (EDC), and extensor digiti minimi (EDM) is measured. Methods Fifth CMCJ arthroscopy is performed on 11 cadaveric hand specimens by specialist-level surgeon. The portals are marked and portal positions are further confirmed under the fluoroscopy. Then the cadaveric specimens were undergone anatomical dissection by specialist-level surgeon. During dissection, the spatial relationship between the portal positions and DCBUN, EDC to ring finger and little finger, and EDM is identified. The distance between the portals and the above important structures was measured in millimeters. Results DCBUN was consistently found between fourth metacarpohamate (4-MH) and fifth metacarpohamate (5-MH) portals, with it being closer to the latter (mean distance, 2.03 mm; range, 0–4.43 mm; standard deviation [SD], 1.09 mm). The closest tendon for 4-MH portal is ring finger EDC (mean distance, 2.65 mm; range, 0–5.89 mm; SD, 1.78 mm), while 5-MH portal and accessory portal were closest to EDC (mean distance, 1.88 mm; range, 0–3.69 mm; SD, 1.25 mm) and EDM (mean distance, 7.79 mm; range, 6.63–10.72 mm; SD, 1.49 mm), respectively. During the process of specimen dissection, we found no damage to the above structures after portal introduction. Conclusion The above findings support the use of fifth CMCJ arthroscopy, which can be used for assisted reduction in fifth metacarpal base fracture dislocation and hamate body fracture. Gentle soft tissue spreading technique during portal creation prevents injury to the important structure surrounding the portals. Level of evidence This is a Level V study.


2010 ◽  
Vol 23 (4) ◽  
pp. 367 ◽  
Author(s):  
Soo Hong Han ◽  
Hyung Ku Yoon ◽  
Dong Eun Shin ◽  
Seung Chul Han ◽  
Young Woong Kim

2016 ◽  
Vol 2016 ◽  
pp. 1-4
Author(s):  
Taranjit Singh Tung

Metatarsophalangeal joint dislocations of lesser toes are often seen in the setting of severe claw toes. Traumatic irreducible dislocations have been reported in rare cases following both low-energy and high-energy injuries to the forefoot. In this case report, I present a previously unreported association of a metatarsal shaft fracture with metatarsophalangeal joint dislocation of a lesser toe.


1995 ◽  
Vol 20 (2) ◽  
pp. 249-252 ◽  
Author(s):  
Y. LIAW ◽  
G. KALNINS ◽  
G. KIRSH ◽  
I. MEAKIN

Three cases of hamato-metacarpal fracture-dislocation with fracture of the shaft or base of the fourth metacarpal and dorsal dislocation of the fifth metacarpal are described. In one case this was associated with coronal fracture of the hamate. An oblique radiograph of the hand with the forearm pronated 15° and 45° provided a good view of the extent of the fourth and fifth carpometacarpal injury. Treatment with open reduction and internal fixation achieves good clinical results.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yung-Cheng Chiu ◽  
Tsung-Yu Ho ◽  
Yen-Nien Ting ◽  
Ming-Tzu Tsai ◽  
Heng-Li Huang ◽  
...  

Abstract Background Metacarpal shaft fracture is a common fracture in hand trauma injuries. Surgical intervention is indicated when fractures are unstable or involve considerable displacement. Current fixation options include Kirschner wire, bone plates, and intramedullary headless screws. Common complications include joint stiffness, tendon irritation, implant loosening, and cartilage damage. Objective We propose a modified fixation approach using headless compression screws to treat transverse or short-oblique metacarpal shaft fracture. Materials and methods We used a saw blade to model transverse metacarpal neck fractures in 28 fresh porcine metacarpals, which were then treated with the following four fixation methods: (1) locked plate with five locked bicortical screws (LP group), (2) regular plate with five bicortical screws (RP group), (3) two Kirschner wires (K group), and (4) a headless compression screw (HC group). In the HC group, we proposed a novel fixation model in which the screw trajectory was oblique to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; thus, the screw did not damage the articular cartilage. The specimens were tested using a modified three-point bending test on a material testing system. The maximum fracture forces and stiffness values of the four fixation types were determined by observing the force–displacement curves. Finally, the Kruskal–Wallis test was adopted to process the data, and the exact Wilcoxon rank sum test with Bonferroni adjustment was performed to conduct paired comparisons among the groups. Results The maximum fracture forces (median ± interquartile range [IQR]) of the LP, RP, HC, and K groups were 173.0 ± 81.0, 156.0 ± 117.9, 60.4 ± 21.0, and 51.8 ± 60.7 N, respectively. In addition, the stiffness values (median ± IQR) of the LP, HC, RP, and K groups were 29.6 ± 3.0, 23.1 ± 5.2, 22.6 ± 2.8, and 14.7 ± 5.6 N/mm, respectively. Conclusion Headless compression screw fixation provides fixation strength similar to locked and regular plates for the fixation of metacarpal shaft fractures. The headless screw was inserted obliquely to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; therefore the articular cartilage iatrogenic injury can be avoidable. This modified fixation method may prevent tendon irritation and joint cartilage violation caused by plating and intramedullary headless screw fixation.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Yung-Cheng Chiu ◽  
Cheng-En Hsu ◽  
Tsung-Yu Ho ◽  
Yen-Nien Ting ◽  
Ming-Tzu Tsai ◽  
...  

Abstract Background Metacarpal shaft fractures are a common hand trauma. The current surgical fixation options for such fractures include percutaneous Kirschner wire pinning and nonlocking and locking plate fixation. Although bone plate fixation, compared with Kirschner wire pinning, has superior fixation ability, a consensus has not been reached on whether the bone plate is better placed on the dorsal or lateral side. Objective The purpose of this study was to evaluate the fixation of locking and regular bone plates on the dorsal and lateral sides of a metacarpal shaft fracture. Materials and methods Thirty-five artificial metacarpal bones were used in the experiment. Metacarpal shaft fractures were created using a saw blade, which were then treated with four types of fixation as follows: (1) a locking plate with four locking bicortical screws on the dorsal side (LP_D); (2) a locking plate with four locking bicortical screws on the lateral side (LP_L); (3) a regular plate with four regular bicortical screws on the dorsal side (RP_D); (4) a regular plate with four regular bicortical screws on the lateral side (RP_D); and (5) two K-wires (KWs). All specimens were tested through cantilever bending tests on a material testing system. The maximum fracture force and stiffness of the five fixation types were determined based on the force–displacement data. The maximum fracture force and stiffness of the specimens with metacarpal shaft fractures were first analyzed using one-way analysis of variance and Tukey’s test. Results The maximum fracture force results of the five types of metacarpal shaft fracture were as follows: LP_D group (230.1 ± 22.8 N, mean ± SD) ≅ RP_D group (228.2 ± 13.4 N) > KW group (94.0 ± 17.4 N) > LP_L group (59.0 ± 7.9 N) ≅ RP_L group (44.5 ± 3.4 N). In addition, the stiffness results of the five types of metacarpal shaft fracture were as follows: LP_D group (68.7 ± 14.0 N/mm) > RP_D group (54.9 ± 3.2 N/mm) > KW group (20.7 ± 5.8 N/mm) ≅ LP_L group (10.6 ± 1.7 N/mm) ≅ RP_L group (9.4 ± 1.2 N/mm). Conclusion According to our results, the mechanical strength offered by lateral plate fixation of a metacarpal shaft fracture is so low that even KW fixation can offer relatively superior mechanical strength; this is regardless of whether a locking or nonlocking plate is used for lateral plate fixation. Such fixation can reduce the probability of extensor tendon adhesion. Nevertheless, our results indicated that when lateral plate fixation is used for fixating a metacarpal shaft fracture in a clinical setting, whether the mechanical strength offered by such fixation would be strong enough to support bone union remains questionable.


2016 ◽  
Vol 15 (2) ◽  
pp. 278-282
Author(s):  
Humberto Ferreira Arquez

Background: The purpose of this paper is to describe an anatomical variation of the hand extensor on the little finger of the right hand which receives four tendons, condition unknown, as it is the first case reported so far in the literature. The human extensor tendons of hand often display an array of variations. Awareness of the anatomy and variations of the extensor tendons on the dorsum of the hand is necessary not only for the anatomist but also for surgeons when considering tendons for hand surgery, tendon rerouting or transplants. Materials and Methods: Bilateral anatomical variation in the upper limb was found during routine dissection in a 75-year-old male cadaver in the Morphology Laboratory at the University of Pamplona. The variations were recorded and photographed. Result: In the left hand the extensor digitorum there was a single tendon to the index, double tendon to the middle, triple tendon to the ring finger, a single tendon to the little finger or digiti minimi. The extensor digiti minimi has double tendon. In the right hand the extensor digitorum there was a single tendon to the index, triple tendon to the middle finger, triple tendons to the ring finger, a double tendon to the little finger. The extensor digiti minimi has double tendon. The little finger receives four tendons, 2 of extensor digitorum and 2 of extensor digiti minimi. The dorsum of the left hand and right showed juncturae tendinum type 2, between the extensors tendons in the 3rd intermetacarpal space; type 3, between the extensors tendons in the 4th inter metacarpal space. Conclusion: The presence of multiple tendons may alter the kinematics around the site of attachment to the phalanx. Knowledge of anatomical variations and normal anatomy of the extensor tendons, may be helpful while performing graft and tendon transfer operations.Bangladesh Journal of Medical Science Vol.15(2) 2016 p.278-282


Sign in / Sign up

Export Citation Format

Share Document