Carwash wastewater treatment by micro and ultrafiltration membranes: Effects of geometry, pore size, pressure difference and feed flow rate in transport properties

2017 ◽  
Vol 17 ◽  
pp. 143-148 ◽  
Author(s):  
Alinne Clície Salgueiro Pinto ◽  
Luiza de Barros Grossi ◽  
Rafael Alvarenga Carvalho de Melo ◽  
Thalles Macedo de Assis ◽  
Vanessa Mendes Ribeiro ◽  
...  
2018 ◽  
Vol 69 (5) ◽  
pp. 1149-1151
Author(s):  
Laura Ruxandra Zicman ◽  
Elena Neacsu ◽  
Felicia Nicoleta Dragolici ◽  
Catalin Ciobanu ◽  
Gheorghe Dogaru ◽  
...  

Ultrafiltration of untreated and pretreated aqueous radioactive wastes was conducted using a spiral-wound polysulphonamide membrane. The influence of process factors on its performances was experimental studied and predicted. Permeate volumetric flux and permeate total suspended solids (TSS) were measured at different values of feed flow rate (7 and 10 m3/h), operating pressure (0.1-0.4 MPa), and feed TSS (15 and 60 mg/L). Permeate flux (42-200 L/(m2�h)) increased with feed flow rate and operating pressure as well as it decreased with an increase in feed TSS, whereas permeate TSS (0.1-33.2 mg/L) exhibited an opposite trend. A 23 factorial plan was used to establish correlations between dependent and independent variables of ultrafiltration process.


2021 ◽  
Vol 1143 (1) ◽  
pp. 012007
Author(s):  
Hary Devianto ◽  
Isdiriyani Nurdin ◽  
Pramujo Widiatmoko ◽  
Kafi Adi Prasetya ◽  
Basil Pradipta

2020 ◽  
Vol 17 (4) ◽  
pp. 47-52
Author(s):  
Vibha Goswami ◽  
Renu Upadhyaya ◽  
Sumanta Kumar Meher

In this study, synthesised Azadirachta indica adsorbent was used for the removal of methylene blue dye using a packed bed column. The effect of feed flow rate, feed methylene blue dye concentration, and bed height of column on percentage removal of dye was studied. It was observed that the column bed exhausted rapidly at a higher flow rate and therefore, a breakthrough occurred faster. However, it was observed that bed exhaustion time increases on increasing the bed height from 2 to 10 inch at 10 mg/L feed dye concentration and feed flow rate of 40 ml/min. It was also found that the breakthrough curve is more dispersed and the percentage removal of dye increases on decreasing the feed methylene dye concentration from 150 to 10 mg/L. The percentage removal was found to be 96.89% at 20 ml/min of feed flow rate under 10 inch of bed height and 10 mg/L of feed dye concentration. The atomic absorption spectrophotometer and scanning electron microscope were used for estimating the effluent dye concentration from the column and morphological study, respectively.


2002 ◽  
Vol 02 (03n04) ◽  
pp. 297-312
Author(s):  
WEN-JEI YANG ◽  
AMR EID ◽  
R. ECHIGO

An experimental study is performed to extract minute gas bubbles from liquids flowing in a simulated cardiopulmonary bypass system using a Venturi-aspirator unit. In other words, oxygen bubbles in oxygenated blood are simulated by air bubbles in water with AP30 (about same viscosity as whole blood). This study is intended to determine the feasibility of using a Venturi aspirator unit to extract minute gas bubbles from a simulated cardiopulmonary bypass system. Testing of the Venturi-type bubble extraction is carried out using three different test sections. Two Venturis are used, and a straight tube configuration is used as a control. The two Venturis are similar, with the exception that one has a longer inlet cone which causes the entering liquid to accelerate at a slower rate. Results are obtained for effectiveness of the aspirator unit as functions of total flow rate, extraction suction, suction pressure difference, and hydraulic head. It is concluded from the study that:(i) The effectiveness of the Venturis is typically between 90 and 100 percent. It increases with an increase in suction or suction pressure difference but decreases with an increase in total flow rate.(ii) The Venturi is most suitable for extraction of minute gas bubbles, especially for use with AP30 (whole blood), which yields substantially higher effectiveness than water.(iii) It is anticipated that a Venturi-aspirator unit can be superior to other bubble separation device as the cardiopulmonary bypass system for applications in extra corporeal blood oxygenation.


2015 ◽  
Vol 474 ◽  
pp. 175-186 ◽  
Author(s):  
Bastien Pellegrin ◽  
Fernanda Mezzari ◽  
Yamina Hanafi ◽  
Anthony Szymczyk ◽  
Jean-Christophe Remigy ◽  
...  