Abstract A single power amplifier-duplexer device was submitted by a customer for analysis. The device was initially considered passing when tested against the production test. However, further electrical testing suggested that the device was stuck in a single power mode for a particular frequency band at cold temperatures only. This paper outlines the systematic isolation of a parasitic Schottky diode formed by a base contactcollector punch through process defect that pulled down the input of a NOR gate leading to the incorrect logic state. Note that this parasitic Schottky diode is parallel to the basecollector junction. It was observed that the logic failure only manifested at colder temperatures because the base contact only slightly diffused into the collector layer. Since the difference in the turn-on voltages between the base-collector junction and the parasitic Schottky diode increases with decreasing temperature, the effect of the parasitic diode is only noticeable at lower temperatures.


2002 ◽  
Vol 50 (6) ◽  
pp. 1590-1602 ◽  
Author(s):  
C.J. Clark ◽  
C.P. Silva ◽  
A.A. Moulthrop ◽  
M.S. Muha

Author(s):  
Gerino Mappatao ◽  
Isaiah Mari Zebedia Bautista ◽  
Marc Kevin Orsos ◽  
Mark Aldrine Ribo ◽  
Joseph Castillo

<span>Whenever a broadcast transmitter is on-air, it is required to be tended by licensed broadcast technicians. Technicians periodically monitor the transmitter performance, record the supply voltage and current at the last stage of the power amplifier and keeps a copy for at least two years. Also recorded are the times the transmitter is turned ON and OFF as well as the times the transmitter shuts down and returns back to air. This paper proposes a system to remotely tend analog transmitters in one central monitoring station. The remote tending of several transmitters in one location is made possible through internet connection. However, the challenge in the proposed system is in the gathering of transmitter data. A prototype of the system was constructed and tested in an FM broadcast transmitter. Test results on the prototype performance show that the proposed system can effectively be used to remotely monitor, record data and control the status of analog broadcast transmitters. The primary feature of the proposed system of monitoring several transmitters in one location will bring cost effective advantages to the broadcast operators. </span>


1989 ◽  
Vol 26 (3) ◽  
pp. 311-326 ◽  
Author(s):  
Siva K. Balasubramanian ◽  
Wagner A. Kamakura

The authors demonstrate how item response theory can be applied for cost effective measurement of consumer attitudes with multi-item scales. The measurement technique they discuss and illustrate is tailored to each respondent so that each is asked only the scale items most informative of his or her attitude level. This approach yields attitude estimates from only a fraction of the total number of items in the attitude scale, with a measurable and controllable increase in the standard error of measurement. Potential cost-saving implications are discussed.


Sign in / Sign up

Export Citation Format

Share Document