scholarly journals A Parametric Study on A Curvature Approximation Based on Interaction Diagrams of Concrete Columns Exposed to An ISO 834 Standard Fire

2017 ◽  
Vol 210 ◽  
pp. 464-471
Author(s):  
Lijie Wang ◽  
Robby Caspeele ◽  
Luc Taerwe
2018 ◽  
Vol 196 ◽  
pp. 02011
Author(s):  
Nikolay Ilyin ◽  
Nadezhda Kondratyeva ◽  
Vasily Zaiko

The research recognizes the necessity of developing a new method of calculation of pipe-concrete columns fire-resistance. It is important for expending the area of their application in construction of buildings and structures; in unique structures as well. The authors apply a simplified mathematical description of the process of pipe-concrete columns resistance to the standard fire effect. This method helps to increase the accuracy of fire resistance level determination to expand these constructions use. If buildings materials are rationally combined, it is possible to produce reliable and sufficiently fireproof structures. Pipe-concrete columns which are, in fact, metal pipes filled with concrete can serve as an example of such structures. Nowadays, field tests are used to determine pipe-concrete constructions fire resistance. The authors introduce a methodology of theoretical determination of pipe-concrete columns fire resistance limit. The use of the proposed methodology makes it possible to reduce labor and economic costs while determining buildings resistance with the use of the pipe-concrete. It opens a possibility of pipe-concrete structures reasonable application in construction practice. The use of this new method allows us to determine pipe-concrete columns fire resistance without resorting to natural fire. It also increases the accuracy of statistical quality control and non-destructive tests. The calculations made in this study as well as previous tests conducted by other researches prove that there is no need for additional fire protection of pipe-concrete columns.


2020 ◽  
Vol 11 (4) ◽  
pp. 529-543
Author(s):  
Anjaly Nair ◽  
Osama (Sam) Salem

Purpose At elevated temperatures, concrete undergoes changes in its mechanical and thermal properties, which mainly cause degradation of strength and eventually may lead to the failure of the structure. Retrofitting is a desirable option to rehabilitate fire damaged concrete structures. However, to ensure safe reuse of fire-exposed buildings and to adopt proper retrofitting methods, it is essential to evaluate the residual load-bearing capacity of such fire-damaged reinforced concrete structures. The focus of the experimental study presented in this paper aims to investigate the fire performance of concrete columns exposed to a standard fire, and then evaluate its residual compressive strengths after fire exposure of different durations. Design/methodology/approach To effectively study the fire performance of such columns, eight identical 200 × 200 × 1,500-mm high reinforced concrete columns test specimens were subjected to two different fire exposure (1- and 2-h) while being loaded with two different load ratios (20% and 40% of the column ultimate design axial compressive load). In a subsequent stage and after complete cooling down, residual compressive strength capacity tests were performed on each fire exposed column. Findings Experimental results revealed that the columns never regain its original capacity after being subjected to a standard fire and that the residual compressive strength capacity dropped to almost 50% and 30% of its ambient temperature capacity for the columns exposed to 1- and 2-h fire durations, respectively. It was also noticed that, for the tested columns, the applied load ratio has much less effect on the column’s residual compressive strength compared to that of the fire duration. Originality/value According to the unique outcomes of this experimental study and, as the fire-damaged concrete columns possessed considerable residual compressive strength, in particular those exposed to shorter fire duration, it is anticipated that with proper retrofitting techniques such as fiber-reinforced polymers (FRP) wrapping, the fire-damaged columns can be rehabilitated to regain at least portion of its lost load-bearing capacities. Accordingly, the residual compressive resistance data obtained from this study can be effectively used but not directly to adopt optimal retrofitting strategies for such fire-damaged concrete columns, as well as to be used in validating numerical models that can be usefully used to account for the thermally-induced degradation of the mechanical properties of concrete material and ultimately predict the residual compressive strengths and deformations of concrete columns subjected to different load intensity ratios for various fire durations.


2014 ◽  
Vol 905 ◽  
pp. 268-272
Author(s):  
In Hwan Yeo ◽  
Bum Yean Cho ◽  
Jae Hong An ◽  
Byung Youl Min

Since the column members in buildings deal with both vertical and horizontal loads, appropriated amount of load should be estimated in order to evaluate the fire resistance performance of the columns under loaded condition. However, according to the ISO 834, the international standard for the evaluation of structural members, the fire resistance performance evaluation of column members is only based on the displacement and displacement rate under loaded condition in a standard fire. The purpose of this study is to suggest appropriate axial load ratios for the evaluation of fire resistance performance. The test conducted in this study produced appropriate axial load ratios for different slenderness ratios. They are expected to contribute to more accurate estimation of fire resistance performance and more efficient and cost-effective structural design.


2016 ◽  
Vol 16 (08) ◽  
pp. 1550050 ◽  
Author(s):  
Lakshitha M. G. Wijesundara ◽  
Simon K. Clubley

This paper details the development of an engineering assessment procedure for reinforced concrete (RC) column failure when subjected to time-variant coupled axial and lateral loads due to internal building detonations. This is based on a comprehensive parametric study conducted using an advanced uncoupled Euler–Lagrange numerical modeling; splitting the structural and flow solvers for maximum integrity and accuracy. The column assessment charts discussed in this paper provide threshold combinations of TNT equivalence and stand-off distance for a range of column residual axial capacity levels corresponding to two key internal blast environments: Vented and contained. This will be of direct relevance to both practitioners and researchers involved with protective design of civilian and military buildings.


2017 ◽  
Vol 19 (5) ◽  
pp. 545-553
Author(s):  
Deuck Hang Lee ◽  
Na-Rae Cheon ◽  
Minsu Kim ◽  
Jungmin Lee ◽  
Jae-Yuel Oh ◽  
...  

2013 ◽  
Vol 639-640 ◽  
pp. 1120-1126
Author(s):  
Guo Feng Wang ◽  
Kai Yu ◽  
Jun Hua Li ◽  
Dong Liang Qiu

The mechanical properties of fire-damage reinforced concrete columns strengthened with bonded steel angles were studied. Nine specimens were tested, including three normal temperature controlled columns, six heated under ISO834 standard fire. After exposure to fire, three of the six were rehabilitated with the bonded steel angles. It was shown by test results that the destructive properties of reinforced concrete columns with bonded steel angles may change and the small eccentric compression specimens may become large eccentric compression due to the steel angles increased the amount of steel in the tension zone of the specimen. In this research, compared with these under normal temperature, the bearing capacity of specimens which were exposure to fire was only ranged from 0.25 to 0.37 times. But the bearing capacity of specimens rehabilitated by the bonded steel angles can increase to 2.86 to 4.04 times of the originals and it can reach to the level of that in normal temperature.


2012 ◽  
Vol 193-194 ◽  
pp. 1429-1435
Author(s):  
Dong Liang Qiu ◽  
Kai Yu ◽  
Guo Feng Wang ◽  
Jun Hua Li

The mechanical properties of fire-damaged reinforced concrete columns rehabilitated by carbon fiber-reinforced polymer (CFRP) rods were studied. This study aims at the effectiveness of CFRP through the contrast test. Nine specimens were tested, including three normal temperature control specimens, and six specimens heated under ISO834 standard fire. After the specimens were exposed to fire, three of them were rehabilitated by CFRP. All specimens were loaded monotonically to failure in the same way. The results showed that the failure of reinforced concrete columns rehabilitated by CFRP was due to losing stabilization, whereas the others were material broken. Furthermore, because of the fire, the load-bearing capacity of specimens was all declined sharply compared with these at normal temperature. From this research, comparing with these normal temperature control specimens, the load-bearing capacity of specimens exposed to fire firstly was ranged from 0.25 to 0.37 times. But the ratio of the loading capacity of specimens rehabilitated by CFRP and normal temperature control ones was ranged from 0.54 to 0.67.


Sign in / Sign up

Export Citation Format

Share Document