scholarly journals Pipe-concrete columns of buildings and their fire-resistance determination

2018 ◽  
Vol 196 ◽  
pp. 02011
Author(s):  
Nikolay Ilyin ◽  
Nadezhda Kondratyeva ◽  
Vasily Zaiko

The research recognizes the necessity of developing a new method of calculation of pipe-concrete columns fire-resistance. It is important for expending the area of their application in construction of buildings and structures; in unique structures as well. The authors apply a simplified mathematical description of the process of pipe-concrete columns resistance to the standard fire effect. This method helps to increase the accuracy of fire resistance level determination to expand these constructions use. If buildings materials are rationally combined, it is possible to produce reliable and sufficiently fireproof structures. Pipe-concrete columns which are, in fact, metal pipes filled with concrete can serve as an example of such structures. Nowadays, field tests are used to determine pipe-concrete constructions fire resistance. The authors introduce a methodology of theoretical determination of pipe-concrete columns fire resistance limit. The use of the proposed methodology makes it possible to reduce labor and economic costs while determining buildings resistance with the use of the pipe-concrete. It opens a possibility of pipe-concrete structures reasonable application in construction practice. The use of this new method allows us to determine pipe-concrete columns fire resistance without resorting to natural fire. It also increases the accuracy of statistical quality control and non-destructive tests. The calculations made in this study as well as previous tests conducted by other researches prove that there is no need for additional fire protection of pipe-concrete columns.

2014 ◽  
Vol 905 ◽  
pp. 268-272
Author(s):  
In Hwan Yeo ◽  
Bum Yean Cho ◽  
Jae Hong An ◽  
Byung Youl Min

Since the column members in buildings deal with both vertical and horizontal loads, appropriated amount of load should be estimated in order to evaluate the fire resistance performance of the columns under loaded condition. However, according to the ISO 834, the international standard for the evaluation of structural members, the fire resistance performance evaluation of column members is only based on the displacement and displacement rate under loaded condition in a standard fire. The purpose of this study is to suggest appropriate axial load ratios for the evaluation of fire resistance performance. The test conducted in this study produced appropriate axial load ratios for different slenderness ratios. They are expected to contribute to more accurate estimation of fire resistance performance and more efficient and cost-effective structural design.


Author(s):  
Patrick Meyer ◽  
Peter Schaumann ◽  
Martin Mensinger ◽  
Suet Kwan Koh

In Germany, regulations for hollow spaces in slab systems require 30 minutes standard fire resistance of the load-bearing steel construction. Within a current national research project a natural fire scenario for the hollow space was developed based on realistic fire loads and ventilation conditions in the hollow space. Assuming this realistic fire scenario in the hollow space, two large scale tests on an innovative composite floor system were performed to evaluate the influence on the load bearing behaviour of the floor system. The integrated and sustainable composite floor system consists of a prestressed concrete slab, an unprotected, bisected hot rolled I-profile with composite dowels either in puzzle or clothoidal shape, and removable floor panels on the top of the I-profile. This floor system ensures the opportunity to adjust the technical building installations in accordance with the use of the building. This integrated and sustainable composite floor system was developed in several research projects. The standard fire resistance R90 for the fire scenario below the slab system has already been proven successfully. In this paper, experimental investigations regarding the heating and load bearing behaviour of the innovative composite floor system under the newly developed natural fire scenario of hollow spaces are presented. In doing so, the special test set-up to realise the fire tests for the fire scenario hollow space will be described in detail. After the fire scenario for the hollow space, the specimen was subjected to the ISO standard fire curve to establish the failure temperature of the unprotected I-profile. In addition to the temperature development and the load bearing behaviour inside the innovative floor during the heating phase, the cooling phase and the influence of a web opening on the load bearing behaviour will be discussed.


2021 ◽  
Vol 11 (6) ◽  
pp. 2521
Author(s):  
Feng Jiang ◽  
Jianyong Liu ◽  
Wei Yuan ◽  
Jianbo Yan ◽  
Lin Wang ◽  
...  

Improving the fire resistance of the key cables connected to firefighting and safety equipment is of great importance. Based on the engineering practice of an oil storage company, this study proposes a modification scheme that entails spraying fire-retardant coatings on the outer surface of a cable tray to delay the failure times of the cables in the tray. To verify the effect, 12 specimens were processed using five kinds of fire-retardant coatings and two kinds of fire-resistant cotton to coat the cable tray. The specimens were installed in the vertical fire resistance test furnace. For the ISO 834 standard fire condition, a fire resistance test was carried out on the specimens. The data for the surface temperature and the insulation resistance of the cables in trays were collected, and the fireproof effect was analyzed. The results showed that compared with the control group, the failure time of the cable could be delayed by 1.57–14.86 times, and the thicker the fire-retardant coatings were, the better the fireproof effect was. In general, the fire protection effect of the fire-retardant coating was better than that of the fire-resistant cotton.


Sign in / Sign up

Export Citation Format

Share Document