Relative K X-ray energy shifts in Fe, Cu and Zn metals and their compounds with EDXRF set-up

2013 ◽  
Vol 83 ◽  
pp. 28-33 ◽  
Author(s):  
Kamaldip Kaur ◽  
Raj Mittal
Keyword(s):  
X Ray ◽  
Set Up ◽  
2007 ◽  
Vol 50 (5) ◽  
pp. 851-860 ◽  
Author(s):  
Maria Sélia Blonski ◽  
Carlos Roberto Appoloni ◽  
Paulo Sérgio Parreira ◽  
Pedro Henrique Arruda Aragão ◽  
Virgilio Franco Nascimento Filho

Energy Dispersion X-Ray Fluorescence Technique (EDXRF) was employed to study the effects of the fumagina disease on the elementary chemical composition of the leaves. The experimental set up consisted of a Mo X-ray tube (Ksub<FONT FACE=Symbol>µ</FONT> = 17.44 keV) with Zr filter and a Si (Li) detector. The measurements were performed with the infected and healthy leaves of citric plants. The elements Ti, Mn, Fe, Cu and Zn were quantified, with an average DL of 69, 12, 8, 4 and 4 µg.g-1 respectively. The obtained concentration for Fe varied from 44 to 192 µg.g-1 in healthy leaves and from 363 to 704 µg.g-1 in infected leaves with fumagina .


Author(s):  
T. Gulik-Krzywicki ◽  
M.J. Costello

Freeze-etching electron microscopy is currently one of the best methods for studying molecular organization of biological materials. Its application, however, is still limited by our imprecise knowledge about the perturbations of the original organization which may occur during quenching and fracturing of the samples and during the replication of fractured surfaces. Although it is well known that the preservation of the molecular organization of biological materials is critically dependent on the rate of freezing of the samples, little information is presently available concerning the nature and the extent of freezing-rate dependent perturbations of the original organizations. In order to obtain this information, we have developed a method based on the comparison of x-ray diffraction patterns of samples before and after freezing, prior to fracturing and replication.Our experimental set-up is shown in Fig. 1. The sample to be quenched is placed on its holder which is then mounted on a small metal holder (O) fixed on a glass capillary (p), whose position is controlled by a micromanipulator.


2021 ◽  
Vol 11 (4) ◽  
pp. 1446
Author(s):  
Jacopo Orsilli ◽  
Anna Galli ◽  
Letizia Bonizzoni ◽  
Michele Caccia

Among the possible variants of X-Ray Fluorescence (XRF), applications exploiting scanning Macro-XRF (MA-XRF) are lately widespread as they allow the visualization of the element distribution maintaining a non-destructive approach. The surface is scanned with a focused or collimated X-ray beam of millimeters or less: analyzing the emitted fluorescence radiation, also elements present below the surface contribute to the elemental distribution image obtained, due to the penetrative nature of X-rays. The importance of this method in the investigation of historical paintings is so obvious—as the elemental distribution obtained can reveal hidden sub-surface layers, including changes made by the artist, or restorations, without any damage to the object—that recently specific international conferences have been held. The present paper summarizes the advantages and limitations of using MA-XRF considering it as an imaging technique, in synergy with other hyperspectral methods, or combining it with spot investigations. The most recent applications in the cultural Heritage field are taken into account, demonstrating how obtained 2D-XRF maps can be of great help in the diagnostic applied on Cultural Heritage materials. Moreover, a pioneering analysis protocol based on the Spectral Angle Mapper (SAM) algorithm is presented, unifying the MA-XRF standard approach with punctual XRF, exploiting information from the mapped area as a database to extend the comprehension to data outside the scanned region, and working independently from the acquisition set-up. Experimental application on some reference pigment layers and a painting by Giotto are presented as validation of the proposed method.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Amara Khan ◽  
Andrea Markus ◽  
Thomas Rittmann ◽  
Jonas Albers ◽  
Frauke Alves ◽  
...  

AbstractX-ray based lung function (XLF) as a planar method uses dramatically less X-ray dose than computed tomography (CT) but so far lacked the ability to relate its parameters to pulmonary air volume. The purpose of this study was to calibrate the functional constituents of XLF that are biomedically decipherable and directly comparable to that of micro-CT and whole-body plethysmography (WBP). Here, we developed a unique set-up for simultaneous assessment of lung function and volume using XLF, micro-CT and WBP on healthy mice. Our results reveal a strong correlation of lung volumes obtained from radiographic XLF and micro-CT and demonstrate that XLF is superior to WBP in sensitivity and precision to assess lung volumes. Importantly, XLF measurement uses only a fraction of the radiation dose and acquisition time required for CT. Therefore, the redefined XLF approach is a promising tool for preclinical longitudinal studies with a substantial potential of clinical translation.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Kuo Men ◽  
Jian-Rong Dai ◽  
Ming-Hui Li ◽  
Xin-Yuan Chen ◽  
Ke Zhang ◽  
...  

Purpose. To develop a dual energy imaging method to improve the accuracy of electron density measurement with a cone-beam CT (CBCT) device.Materials and Methods. The imaging system is the XVI CBCT system on Elekta Synergy linac. Projection data were acquired with the high and low energy X-ray, respectively, to set up a basis material decomposition model. Virtual phantom simulation and phantoms experiments were carried out for quantitative evaluation of the method. Phantoms were also scanned twice with the high and low energy X-ray, respectively. The data were decomposed into projections of the two basis material coefficients according to the model set up earlier. The two sets of decomposed projections were used to reconstruct CBCT images of the basis material coefficients. Then, the images of electron densities were calculated with these CBCT images.Results. The difference between the calculated and theoretical values was within 2% and the correlation coefficient of them was about 1.0. The dual energy imaging method obtained more accurate electron density values and reduced the beam hardening artifacts obviously.Conclusion. A novel dual energy CBCT imaging method to calculate the electron densities was developed. It can acquire more accurate values and provide a platform potentially for dose calculation.


2013 ◽  
Vol 21 (1) ◽  
pp. 1-4 ◽  
Author(s):  
Hiroyuki Kishimoto ◽  
Yuya Shinohara ◽  
Yoshio Suzuki ◽  
Akihisa Takeuchi ◽  
Naoto Yagi ◽  
...  

A pinhole-type two-dimensional ultra-small-angle X-ray scattering set-up at a so-called medium-length beamline at SPring-8 is reported. A long sample-to-detector distance, 160.5 m, can be used at this beamline and a small-angle resolution of 0.25 µm−1was thereby achieved at an X-ray energy of 8 keV.


2008 ◽  
Vol 15 (6) ◽  
pp. 600-605 ◽  
Author(s):  
Michael Paulus ◽  
Daniela Lietz ◽  
Christian Sternemann ◽  
Kaveh Shokuie ◽  
Florian Evers ◽  
...  
Keyword(s):  
X Ray ◽  

2018 ◽  
Vol 124 (16) ◽  
pp. 164906 ◽  
Author(s):  
Cui Zhang ◽  
Xiaodong Pan ◽  
Hongjie Shang ◽  
Gongping Li

2004 ◽  
Vol 38 (4-6) ◽  
pp. 839-842 ◽  
Author(s):  
A.S. Potapov ◽  
P.A. Rodnyi ◽  
S.B. Mikhrin

Sign in / Sign up

Export Citation Format

Share Document