Effect of depth and fluid flow rate on estimate for borehole thermal resistance of single U-pipe borehole heat exchanger

2020 ◽  
Vol 147 ◽  
pp. 2399-2408 ◽  
Author(s):  
Changxing Zhang ◽  
Xinjie Wang ◽  
Pengkun Sun ◽  
Xiangqiang Kong ◽  
Shicai Sun
Author(s):  
Randall D. Manteufel ◽  
Daniel G. Vecera

Recent experimental work characterized the performance of a unique cross-flow heat exchanger design for application of cooling compressor bleed air using liquid jet fuel before it is consumed in the gas turbine combustor. The proposed design has micro-channels for liquid fuel and cools air flowing in passages created using rows of intermittent fins. The design appears well suited for aircraft applications because it is compact and light-weight. A theoretical model is reported to be in good agreement with experimental measurements using air and water, thus providing a design tool to evaluate variations in the heat exchanger dimensions. This paper presents an evaluation of the heat exchanger performance with consideration of uncertainties in both model parameters and predicted results. The evaluation of the design is proposed to be reproduced by students in a thermal-fluids design class. The heat exchanger performance is reevaluated using the effectiveness–NTU approach and shown to be consistent with the method reported in the original papers. Results show that the effectiveness is low and in the range of 20 to 30% as well as the NTU which ranges from 0.25 to 0.50 when the heat capacity ratio is near unity. The thermal resistance is dominated by the hot gas convective resistance. The uncertainties attributed to fluid properties, physical dimensions, gas pressure, and cold fluid flow rate are less significant when compared to uncertainties associated with hot fluid flow rate, hot fluid inlet temperature, cold fluid inlet temperature, and convective correlation for gas over a finned surface. The model shows which heat transfer mechanisms are most important in the performance of the heat exchanger.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3877
Author(s):  
Samuel Boahen ◽  
Kwesi Mensah ◽  
Selorm Kwaku Anka ◽  
Kwang Ho Lee ◽  
Jong Min Choi

The detection and diagnosis of faults is becoming necessary in ensuring energy savings in heat pump units. Faults can exist independently or simultaneously in heat pumps at the refrigerant side and secondary fluid flow loops. In this work, we discuss the effects that simultaneous refrigerant charge faults and faults associated with the flow rate of secondary fluids have on the performance of a heat pump operating in summer season and we developed a correlation to detect and diagnose these faults using multiple linear regression. The faults considered include simultaneous refrigerant charge and indoor heat exchanger secondary fluid flow rate faults (IFRFs), simultaneous refrigerant charge and outdoor heat exchanger secondary fluid flow rate faults (OFRFs) and simultaneous refrigerant charge, IFRF and OFRF. The occurrence of simultaneous refrigerant charge fault, IFRF and OFRF caused up to a 5.7% and 8% decrease in cooling capacity compared to simultaneous refrigerant charge and indoor heat exchanger secondary fluid flow rate faults, and simultaneous refrigerant charge and outdoor heat exchanger secondary fluid flow rate faults, respectively. Simultaneous refrigerant charge fault, IFRF and OFRF resulted in up to an 11.6% and 5.9% decrease in COP of the heat pump unit compared to simultaneous refrigerant charge fault and IFRF, and simultaneous refrigerant charge fault and OFRF, respectively. The developed FDD correlations accurately predicted the simultaneous refrigerant charge and faults in the flow rate of the secondary fluid within an error margin of 7.7%.


Author(s):  
Yu. E. Nikolaenko ◽  
О. V. Baranyuk ◽  
S. A. Reva

The paper presents the results on numerical simulation of the temperature field of a cold plate type liquid heat exchanger for a multichannel transmitter/receiver module. Each side of the cold plate carries 8 local microwave fuel elements with a heat dissipation capacity of 11 W each and one block with low-power electronic elements (total power of all elements — 50 W), installed symmetrically on both sides. The total heat dissipation capacity is 276 W. The cold plate is cooled by pumping a liquid heat carrier (Antifreeze A 65) through a curved cooling channel of rectangular cross-section made inside the liquid heat exchanger. The study was conducted at a working fluid flow rate of 2, 4, 6, 8 and 10 l/min. Numerical simulation allowed obtaining the temperature distribution of the mounting surfaces of the cold plate and determining the values of the working fluid flow rate, which provide effective cooling of the mounting surfaces. It is shown that at a flow rate of 4 l/min, the temperature values at the installation sites of local microwave elements do not exceed 64°C. The total thermal resistance of the cooling system based on a liquid heat exchanger is from 0.063 to 0.028°C/W with a flow rate from 2 to 10 l/min, respectively.


2019 ◽  
Vol 11 (1) ◽  
pp. 01025-1-01025-5 ◽  
Author(s):  
N. A. Borodulya ◽  
◽  
R. O. Rezaev ◽  
S. G. Chistyakov ◽  
E. I. Smirnova ◽  
...  

1956 ◽  
Vol 23 (2) ◽  
pp. 269-272
Author(s):  
L. F. Welanetz

Abstract An analysis is made of the suction holding power of a device in which a fluid flows radially outward from a central hole between two parallel circular plates. The holding power and the fluid flow rate are determined as functions of the plate separation. The effect of changing the proportions of the device is investigated. Experiments were made to check the analysis.


2019 ◽  
Vol 27 (02) ◽  
pp. 1950015 ◽  
Author(s):  
Keun Sun Chang ◽  
Young Jae Kim ◽  
Min Jun Kim

The standing column well (SCW) for ground source heat pump (GSHP) systems is a highly promising technology with its high heat capacity and efficiency. In this study, a large-scale thermal response tester has been built, which is capable of imposing a wide range of heat on the SCW ground heat exchangers and measuring time responses of their thermal parameters. Two standing column wells in one site but with different well hydrological and geological conditions are tested to study their effects on the thermal performances. Borehole thermal resistance ([Formula: see text]) and the effective thermal conductivity ([Formula: see text]) are derived from data obtained from the thermal response test (TRT) by using a line source method. Results show that the influence of groundwater movement on the thermal conductivity of the SCW is not very significant (3.6% difference between two different geological conditions). This indicates that results of one TRT measurement can be applied to other SCWs in the same site, with which considerable time and cost are saved. The increase of circulation flow rate enhances the ground thermal conductivity moderately (4.5% increase with flow rate increase of 45%), but the borehole thermal resistance is substantially lowered (about 25.9%).


Sign in / Sign up

Export Citation Format

Share Document