Improvement in the surface properties of stainless steel via zein/hydroxyapatite composite coatings for biomedical applications

2020 ◽  
Vol 20 ◽  
pp. 100589 ◽  
Author(s):  
Yusra Ahmed ◽  
Muhammad Atiq Ur Rehman
Surfaces ◽  
2020 ◽  
Vol 3 (2) ◽  
pp. 237-250 ◽  
Author(s):  
Yusra Ahmed ◽  
Muhammad Yasir ◽  
Muhammad Atiq Ur Rehman

Stainless steel is renowned for its wide use as a biomaterial, but its relatively high corrosion rate in physiological environments restricts many of its clinical applications. To overcome the corrosion resistance of stainless steel bio-implants in physiological environments and to improve its osseointegration behavior, we have developed a unique zein/hydroxyapatite (HA) composite coating on a stainless steel substrate by Electrophoretic Deposition (EPD). The EPD parameters were optimized using the Taguchi Design of experiments (DoE) approach. The EPD parameters, such as the concentration of bio-ceramic particles in the polymer solution, applied voltage and deposition time were optimized on stainless steel substrates by applying a mixed design orthogonal Taguchi array. The coatings were characterized by using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and wettability studies. SEM images and EDX results indicated that the zein/HA coating was successfully deposited onto the stainless steel substrates. The wettability and roughness studies elucidated the mildly hydrophilic nature of the zein/HA coatings, which confirmed the suitability of the developed coatings for biomedical applications. Zein/HA coatings improved the corrosion resistance of bare 316L stainless steel. Moreover, zein/HA coatings showed strong adhesion with the 316L SS substrate for biomedical applications. Zein/HA developed dense HA crystals upon immersion in simulated body fluid, which confirmed the bone binding ability of the coatings. Thus the zein/HA coatings presented in this study have a strong potential to be considered for orthopedic applications.


2012 ◽  
Vol 507 ◽  
pp. 127-133 ◽  
Author(s):  
Sigrid Seuss ◽  
Tayyab Subhani ◽  
Min Yi Kang ◽  
Kenji Okudaira ◽  
Isaac E. Aguilar Ventura ◽  
...  

Electrophoretic deposition (EPD) has been successfully used to deposit composite coatings composed of polyetheretherketone (PEEK) and titanium dioxide (TiO2) nanoparticles on 316L stainless steel substrates. The suspensions of TiO2 nanoparticles and PEEK microparticles for EPD were prepared in ethanol. PEEK-TiO2 composite coatings were optimized using suspensions containing 6wt% PEEK-TiO2 in ethanol with a 3:1 ratio of PEEK to TiO2 in weight and by applying a potential difference of 30 V for 1 minute. A heat-treatment process of the optimized PEEK-TiO2 composite coatings was performed at 335°C for 30 minutes with a heating rate of 10°Cminto densify the deposits. The EPD coatings were microstructurally evaluated by scanning electron microscopy (SEM). It was demonstrated that EPD is a convenient and rapid method to fabricate PEEK/TiO2 coatings on stainless steel which are interesting for biomedical applications.


2015 ◽  
Vol 332 ◽  
pp. 62-69 ◽  
Author(s):  
Yajing Yan ◽  
Xuejiao Zhang ◽  
Caixia Li ◽  
Yong Huang ◽  
Qiongqiong Ding ◽  
...  

2018 ◽  
Vol 169 ◽  
pp. 176-182 ◽  
Author(s):  
Fatih E. Baştan ◽  
Muhammad Atiq Ur Rehman ◽  
Yasemin Yıldıran Avcu ◽  
Egemen Avcu ◽  
Fatih Üstel ◽  
...  

Coatings ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 423
Author(s):  
Hsien-Yeh Chen ◽  
Peng-Yuan Wang

The success of recent material science and applications in biotechnologies should be credited to developments of malleable surface properties, as well as the adaptation of conjugation reactions to the material surface [...]


Coatings ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 515
Author(s):  
Tongfang Liu ◽  
Song Rui ◽  
Sheng Li

Mg alloys are promising biomedical metal due to their natural degradability, good processability, and favorable mechanical properties. However, the poor corrosion resistance limits their further clinical applications. In this study, the combined strategies of surface chemical treatment and layer-by-layer self-assembly were used to prepare composite coatings on Mg alloys to improve the biocorrosion resistance. Specially, alkalized AZ91 Mg alloy generated chemical linkage with silane via Si–O–Mg covalent bond at the interface. Subsequently, Si–OH group from silane formed a crosslinked silane layer by Si–O–Si network. Further chemical assembly with graphene oxide (GO), lengthened the diffusion pathway of corrosive medium. The chemically assembled composite coatings could firmly bond to Mg alloy substrate, which persistently and effectively acted as compact barriers against corrosion propagation. Improved biocorrosion resistance of AZ91 Mg alloy with self-assembly composite coatings of silane/GO was subsequently confirmed by immersion tests. Besides, the Mg alloy exhibited good wear resistance due to outside layer of GO with a lubricant effect. Cell viability of higher than 75% had also been found for the alloy with self-assembly composite coatings, which showed good cytocompatibility.


Sign in / Sign up

Export Citation Format

Share Document