Square-wave stripping voltammetric determination of caffeic acid on electrochemically reduced graphene oxide–Nafion composite film

Talanta ◽  
2013 ◽  
Vol 116 ◽  
pp. 245-250 ◽  
Author(s):  
Hayati Filik ◽  
Gamze Çetintaş ◽  
Asiye Aslıhan Avan ◽  
Sevda Aydar ◽  
Serkan Naci Koç ◽  
...  
2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Gen Liu ◽  
Wei Ma ◽  
Yan Luo ◽  
Deng-ming Sun ◽  
Shuang Shao

Poly(methylene blue) and electrochemically reduced graphene oxide composite film modified electrode (PMB-ERGO/GCE) was successfully fabricated by electropolymerization and was used for simultaneous determination of uric acid (UA) and xanthine (Xa). Based on the excellent electrocatalytic activity of PMB-ERGO/GCE, the electrochemical behaviors of UA and Xa were studied by cyclic voltammetry (CV) and square wave voltammetry (SWV). Two anodic sensitive peaks at 0.630 V (versus Ag/AgCl) for UA and 1.006 V (versus Ag/AgCl) for Xa were given by CV in pH 3.0 phosphate buffer. The calibration curves for UA and Xa were obtained in the range of 8.00 × 10−8~4.00 × 10−4 M and 1.00 × 10−7~4.00 × 10−4 M, respectively, by SWV. The detection limits for UA and Xa were3.00×10-8 M and5.00×10-8 M, respectively. Finally, the proposed method was applied to simultaneously determine UA and Xa in human urine with good selectivity and high sensitivity.


Author(s):  
Yanju Wu ◽  
Zikang Li ◽  
Dongyang Han ◽  
Qunpeng Duan ◽  
Fei Wang

Abstract On the surface of a glassy carbon electrode, electrochemically reduced graphene oxide-cationic pillar[6]arene (ErGO-CP6) composite film was constructed using a pulsed potential method. UV-vis spectra, SEM, Raman spectra and electrochemical experiments were applied to characterize the composite film. It was then used as a new electrochemical sensing platform for determination of thiamethoxam. Due to the synergistic effect of ErGO and CP6, this composite film shows a higher sensitivity and better selectivity toward thiamethoxam than that of ErGO film. The linear range from 1.0 × 10-7 to 1.3 × 10-5 mol L-1 was obtained by differential pulse voltammetry. Meanwhile, the method was applied to cucumber and tomato samples in a recovery test. The recovery was between 92.0% and 98.7%, and the results are satisfactory. This study presents a promising electrochemical sensing platform for rapid and sensitive analysis of thiamethoxam.


2021 ◽  
Vol 13 (1) ◽  
pp. 56-63
Author(s):  
Qiuqiu Wang ◽  
Juanhua Zhang ◽  
Yanbo Xu ◽  
Yingyi Wang ◽  
Liang Wu ◽  
...  

One-step electrochemically reduced graphene oxide with high surface area and improved electron transfer kinetics shows great performances in the determination of furfural in dairy milk.