Fully automated, low-cost ion chromatography system for in-situ analysis of nitrite and nitrate in natural waters

Talanta ◽  
2020 ◽  
Vol 216 ◽  
pp. 120955 ◽  
Author(s):  
Eoin Murray ◽  
Patrick Roche ◽  
Matthieu Briet ◽  
Breda Moore ◽  
Aoife Morrin ◽  
...  
Chemosensors ◽  
2018 ◽  
Vol 6 (4) ◽  
pp. 57 ◽  
Author(s):  
Andrew Donohoe ◽  
Gareth Lacour ◽  
Peter McCluskey ◽  
Dermot Diamond ◽  
Margaret McCaul

A sensing platform for the in situ, real-time analysis of phosphate in natural waters has been realised using a combination of microfluidics, colorimetric reagent chemistries, low-cost LED-based optical detection and wireless communications. Prior to field deployment, the platform was tested over a period of 55 days in the laboratory during which a total of 2682 autonomous measurements were performed (854 each of sample, high standard and baseline, and 40 × 3 spiked solution measurements). The platform was subsequently field-deployed in a freshwater stream at Lough Rea, Co., Galway, Ireland, to track changes in phosphate over a five day period. During this deployment, 165 autonomous measurements (55 each of sample, high standard, and baseline) were performed and transmitted via general packet radio service (GPRS) to a web interface for remote access. Increases in phosphate levels at the sampling location coincident with rainfall events (min 1.45 µM to max 10.24 µM) were detected during the deployment. The response was found to be linear up to 50 µM PO43−, with a lower limit of detection (LOD) of 0.09 µM. Laboratory and field data suggest that despite the complexity of reagent-based analysers, they are reasonably reliable in remote operation, and offer the best opportunity to provide enhanced in situ chemical sensing capabilities. Modifications that could further improve the reliability and scalability of these platforms while simultaneously reducing the unit cost are discussed.


2015 ◽  
Vol 7 (13) ◽  
pp. 5396-5405 ◽  
Author(s):  
Deirdre Cogan ◽  
Cormac Fay ◽  
David Boyle ◽  
Conor Osborne ◽  
Nigel Kent ◽  
...  

This study has demonstrated, for the first time, a microfluidic autonomous analyser for the direct determination of nitrate, incorporating a modified version of the chromotropic method resulting in a direct, quick, inexpensive and simple procedure to measure nitrate in situ.


2012 ◽  
Vol 46 (17) ◽  
pp. 9548-9556 ◽  
Author(s):  
Alexander D. Beaton ◽  
Christopher L. Cardwell ◽  
Rupert S. Thomas ◽  
Vincent J. Sieben ◽  
François-Eric Legiret ◽  
...  

2021 ◽  
Author(s):  
Andrew C. Bauer ◽  
James R. Forsythe ◽  
Jay Sitaraman ◽  
Andrew M. Wissink ◽  
Buvaneswari Jayaraman ◽  
...  
Keyword(s):  

Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.