Ultrasensitive early detection of insulin antibody employing novel electrochemical nano-biosensor based on controllable electro-fabrication process

Talanta ◽  
2021 ◽  
pp. 122947
Author(s):  
Mohammadreza Farrokhnia ◽  
Ghassem Amoabediny ◽  
Mohammad Ebrahimi ◽  
Mohammadreza Ganjali ◽  
Mohammad Arjmand
Author(s):  
Burton B. Silver ◽  
Ronald S. Nelson

Some investigators feel that insulin does not enter cells but exerts its influence in some manner on the cell surface. Ferritin labeling of insulin and insulin antibody was used to determine if binding sites of insulin to specific target organs could be seen with electron microscopy.Alloxanized rats were considered diabetic if blood sugar levels were in excess of 300 mg %. Test reagents included ferritin, ferritin labeled insulin, and ferritin labeled insulin antibody. Target organs examined were were diaphragm, kidney, gastrocnemius, fat pad, liver and anterior pituitary. Reagents were administered through the left common carotid. Survival time was at least one hour in test animals. Tissue incubation studies were also done in normal as well as diabetic rats. Specimens were fixed in gluteraldehyde and osmium followed by staining with lead and uranium salts. Some tissues were not stained.


Author(s):  
M.G. Rosenfield

Minimum feature sizes in experimental integrated circuits are approaching 0.5 μm and below. During the fabrication process it is usually necessary to be able to non-destructively measure the critical dimensions in resist and after the various process steps. This can be accomplished using the low voltage SEM. Submicron linewidth measurement is typically done by manually measuring the SEM micrographs. Since it is desirable to make as many measurements as possible in the shortest period of time, it is important that this technique be automated.Linewidth measurement using the scanning electron microscope is not well understood. The basic intent is to measure the size of a structure from the secondary electron signal generated by that structure. Thus, it is important to understand how the actual dimension of the line being measured relates to the secondary electron signal. Since different features generate different signals, the same method of relating linewidth to signal cannot be used. For example, the peak to peak method may be used to accurately measure the linewidth of an isolated resist line; but, a threshold technique may be required for an isolated space in resist.


2001 ◽  
Vol 120 (5) ◽  
pp. A606-A606
Author(s):  
Y MORII ◽  
T YOSHIDA ◽  
T MATSUMATA ◽  
T ARITA ◽  
K SHIMODA ◽  
...  

2004 ◽  
Vol 171 (4S) ◽  
pp. 481-481
Author(s):  
Ravery V. Vincent ◽  
Chautard D. Denis ◽  
Arnauld A. Villers ◽  
Laurent Boccon Gibbod

2003 ◽  
Vol 2 (1) ◽  
pp. 136
Author(s):  
C MEUNE ◽  
C GIRAUDEAU ◽  
H BECANE ◽  
O PASCAL ◽  
P LAFORET ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document