Evaluation of tissue response to MTA and Portland cement with iodoform

Author(s):  
Carlos Alberto Herrero de Morais ◽  
Norberti Bernardineli ◽  
Roberto B. Garcia ◽  
Marco A.H. Duarte ◽  
Danilo M.Z. Guerisoli
2015 ◽  
Vol 260 (3) ◽  
pp. 281-286 ◽  
Author(s):  
N. MARQUES ◽  
N. LOURENÇO NETO ◽  
A.P. FERNANDES ◽  
C. RODINI ◽  
M. HUNGARO DUARTE ◽  
...  

2013 ◽  
Vol 24 (1) ◽  
pp. 10-14 ◽  
Author(s):  
Nádia Carolina Teixeira Marques ◽  
Natalino Lourenço Neto ◽  
Ana Paula Fernandes ◽  
Camila de Oliveira Rodini ◽  
Marco Antônio Hungaro Duarte ◽  
...  

The aim of this study was to evaluate the response of rat subcutaneous tissue to MTA Fillapex® (Angelus), an experimental root canal filling material based on Portland cement and propylene glycol (PCPG), and a zinc oxide, eugenol and iodoform (ZOEI) paste. These materials were placed in polyethylene tubes and implanted into the dorsal connective tissue of Wistar rats for 7 and 15 days. The specimens were stained with hematoxylin and eosin, and evaluated regarding inflammatory reaction parameters by optical microscopy. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated examiners for all experimental periods (kappa=0.96). The histological evaluation showed that all materials caused a moderate inflammatory reaction at 7 days, which subsided with time. A greater inflammatory reaction was observed at 7 days in the tubes filled with ZOEI paste. Tubes filled with MTA Fillapex presented some giant cells, macrophages and lymphocytes after 7 days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The tubes filled with PCPG showed similar results to those observed in MTA Fillapex. At 15 days, the inflammatory reaction was almost absent at the tissue, with several collagen fibers indicating normal tissue healing. Data were analyzed by the nonparametric Kruskal-Wallis test (α=0.05). Statistically significant difference (p<0.05) was found only between PCPG at 15 days and ZOEI at 7 days groups. No significant differences were observed among the other groups/periods (p>0.05). MTA Fillapex and Portland cement added with propylene glycol had greater tissue compatibility than the PCPG paste.


2009 ◽  
Vol 20 (2) ◽  
pp. 112-117 ◽  
Author(s):  
Ricardo Martínez Lalis ◽  
María Laura Esaín ◽  
Gabriel A. Kokubu ◽  
Julia Willis ◽  
Carolina Chaves ◽  
...  

The purpose of this study was compare the biocompatibility of modified Portland cement (CPM) and mineral trioxide aggregate (MTA) in a subcutaneous rat model. Twenty-four male Wistar rats were used. Three silicon tubes were placed on the dorsal subcutaneous tissue of each animal: one tube contained MTA, one tube contained CPM and the other was an empty tube. The rats were sacrificed in 3 groups of 8 animals at 7, 14 and 30 postoperative days, respectively. Tissue samples were fixed in 10% buffered formalin, embedded in paraffin, and serial sections were cut and stained with hematoxylin and eosin, Masson Trichrome and Luna's stain. At day 7, the empty tubes displayed a mild inflammatory infiltrate. In the CPM group, an inflammatory infiltrate was observed with some eosinophils and immature connective tissue. The MTA group showed a similar infiltrate without eosinophils and presence of abundant necrotic tissue and numerous multinucleate foreign body giant cells. At day 14, the chronic infiltrate with eosinophils persisted when in contact with CPM. In the MTA group, necrosis and distant giant cells could still be seen. At day 30, all 3 groups showed mature fibrous collagenous tissue. These findings indicate a different response to the materials evaluated in this study. Although, MTA and CPM induced a chronic inflammatory infiltrate, necrosis and multinucleated foreign body giant cells predominated in the MTA group, while in the CPM group numerous eosinophils were seen at all the observational periods.


Author(s):  
R.F. Dodson ◽  
L.W-F Chu ◽  
N. Ishihara

The extent of damage surrounding an implanted electrode in the cerebral cortex is a question of significant importance with regard to attaining consistency and validity of physiological recordings. In order to determine the extent of such tissue changes, 150 micron diameter platinum electrodes were implanted in the cortex of four adult baboons, and after eight days the animals were sacrificed by whole body perfusion with a 3% glutaraldehyde in 0.1M phosphate fixative.The calvarium was carefully removed and the electrode tracts were readily discernible in the firm, glutaraldehyde fixed tissue.Careful dissection of the zone of the electrode tract resulted in a small block which was further sectioned into tip, mid-tract and surface areas. Ultrastructurally, damage extended from the electrode sheath to the greatest extent of from 0.2 to 3.5 mm.


1898 ◽  
Vol 46 (1192supp) ◽  
pp. 19108-19109
Author(s):  
Bernard L. Green

Kidney Cancer ◽  
2020 ◽  
Vol 4 (3) ◽  
pp. 151-158
Author(s):  
Katherine Yuxi Tai ◽  
Jad M. El Abiad ◽  
Carol D. Morris ◽  
Mark Christopher Markowski ◽  
Adam S. Levin

BACKGROUND: Checkpoint inhibitors and receptor tyrosine kinase inhibitors (RTKIs) have changed the standard of care for metastatic renal cell carcinoma (mRCC). Anecdotal evidence suggests these therapies may be less effective for treating bone than soft-tissue metastases. PURPOSE: We performed a retrospective review evaluating the relative clinical responses in soft-tissue and bone metastases in patients undergoing therapy using RTKIs and anti-programmed death-1 (PD-1) agents for mRCC. METHODS: Of the 2,212 patients in our institutional cancer registry with renal cell carcinoma (1997–2017), 68 (82 disease courses) were identified with measurable bone and soft-tissue metastases treated with RTKIs and/or PD-1s. Extent of metastasis was quantified at the time of therapy initiation (baseline) and at 3 months, 6 months, and 1 year. Changes in disease status were categorized as complete response, partial response, stable, mixed, or progression of disease according to RECIST v1.1 and MD Anderson criteria. These categories were further organized into “response to treatment” or “evidence of progression” to generate a generalized linear effects model with soft-tissue response as the independent variable and bone response as the dependent variable. Alpha = 0.05. RESULTS: Soft-tissue response correlated with bone response at 3 months (76 disease courses, p = 0.005) and 6 months (48 disease courses, p = 0.017). Of the patients with controlled soft-tissue disease, only 14 (19%) and 15 (32%) had progression in bone at 3 and 6 months, respectively. CONCLUSION: Contrary to anecdotal reports, osseous metastases do not appear to respond worse than soft-tissue metastases to treatment with these agents.


1997 ◽  
Vol 503 ◽  
Author(s):  
B. K. Diefenderfer ◽  
I. L. Al-Qadi ◽  
J. J. Yoho ◽  
S. M. Riad ◽  
A. Loulizi

ABSTRACTPortland cement concrete (PCC) structures deteriorate with age and need to be maintained or replaced. Early detection of deterioration in PCC (e.g., alkali-silica reaction, freeze/thaw damage, or chloride presence) can lead to significant reductions in maintenance costs. However, it is often too late to perform low-cost preventative maintenance by the time deterioration becomes evident. By developing techniques that would enable civil engineers to evaluate PCC structures and detect deterioration at early stages (without causing further damage), optimization of life-cycle costs of the constructed facility and minimization of disturbance to the facility users can be achieved.Nondestructive evaluation (NDE) methods are potentially one of the most useful techniques ever developed for assessing constructed facilities. They are noninvasive and can be performed rapidly. Portland cement concrete can be nondestructively evaluated by electrically characterizing its complex dielectric constant. The real part of the dielectric constant depicts the velocity of electromagnetic waves in PCC. The imaginary part, termed the “loss factor,” describes the conductivity of PCC and the attenuation of electromagnetic waves.Dielectric properties of PCC have been investigated in a laboratory setting using a parallel plate capacitor operating in the frequency range of 0.1 to 40.1MIHz. This capacitor set-up consists of two horizontal-parallel plates with an adjustable separation for insertion of a dielectric specimen (PCC). While useful in research, this approach is not practical for field implementation. A new capacitor probe has been developed which consists of two plates, located within the same horizontal plane, for placement upon the specimen to be tested. Preliminary results show that this technique is feasible and results are promising; further testing and evaluation is currently underway.


Sign in / Sign up

Export Citation Format

Share Document