Effect of Ultrasonic Excitation on the Microtensile Bond Strength of Glass Ionomer Cements to Dentin After Different Water Storage Times

2011 ◽  
Vol 37 (12) ◽  
pp. 2133-2138 ◽  
Author(s):  
Elcilaine Rizzato Azevedo ◽  
Cármen Regina Coldebella ◽  
Ângela Cristina Cilense Zuanon
2019 ◽  
Vol 44 (6) ◽  
pp. E289-E298 ◽  
Author(s):  
CRG van den Breemer ◽  
M Özcan ◽  
MS Cune ◽  
AP Almeida Ayres ◽  
B Van Meerbeek ◽  
...  

SUMMARY This study evaluated the microtensile bond strength (μTBS) of resin-based composite (RBC) to dentin after different immediate dentin sealing (IDS) strategies and surface-conditioning (SC) methods and on two water storage times. Human molars (n=48) were randomly divided into eight experimental groups involving four different IDS strategies—IDS-1L with one layer of adhesive, IDS-2L with two layers of adhesive, IDS-F with one layer of adhesive and one layer of flowable RBC, and DDS (delayed dentin sealing) with no layer of adhesive (control)—and two different SC methods—SC-P with pumice rubbing and SC-PC with pumice rubbing followed by tribochemical silica coating. The μTBS test was performed after one week and after six months of water storage, being recorded as the “immediate” and “aged” μTBS, respectively. Composite-adhesive-dentin microspecimens (0.9×0.9×8–9 mm) were stressed in tension until failure to determine the μTBS. Failure mode and location of failure were categorized. Two-way analysis of variance was applied to analyze the data for statistically significant differences between the experimental groups (p<0.05). Two-way analysis of variance revealed no significant differences between the one-week μTBS specimens for IDS strategy (p=0.087) and SC methods (p=0.806). However, the interaction of IDS strategy and SC methods appeared statistically significant (p=0.016). The six-month specimen evaluation showed no significant difference in μTBS for SC (p=0.297) and SC/IDS interaction (p=0.055), but the μTBS of the IDS strategies differed significantly among them (p=0.003). For tribochemical silica-coated IDS, no significant effect of aging on μTBS was recorded (p=0.465), but there was a highly significant difference in μTBS depending on the IDS strategy (p<0.001). In addition, the interaction of IDS and aging was borderline statistically significant (p=0.045). The specimens failed mainly at the adhesive-dentin interface for all experimental groups. Dentin exposure during clinical procedures for indirect restorations benefits from the application of IDS, which was shown to result in higher bond strength. No significant differences were found between cleaning with solely pumice or pumice followed by tribochemical silica coating.


2006 ◽  
Vol 31 (5) ◽  
pp. 590-597 ◽  
Author(s):  
K. Choi ◽  
Y. Oshida ◽  
J. A. Platt ◽  
M. A. Cochran ◽  
B. A. Matis ◽  
...  

Clinical Relevance The mean microtensile bond strengths of glass ionomer cements to carious dentin were significantly lower than to sound dentin.


2007 ◽  
Vol 25 (5) ◽  
pp. 402-406 ◽  
Author(s):  
Atefeh Yousefi Jordehi ◽  
Amir Ghasemi ◽  
Maryam Moezi Zadeh ◽  
Reza Fekrazad

2012 ◽  
Vol 17 (6) ◽  
pp. 154-159 ◽  
Author(s):  
Marcel M. Farret ◽  
Eduardo Martinelli de Lima ◽  
Eduardo Gonçalves Mota ◽  
Hugo Mitsuo S. Oshima ◽  
Gabriela Maguilnik ◽  
...  

OBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selected. For the compressive strength and diametral tensile strength tests, 12 specimens were made of each material. For the microhardness test 15 specimens were made of each material and for the shear bond strength tests 45 bovine permanent incisors were used mounted in a self-cure acrylic resin. Then, band segments with a welded bracket were cemented on the buccal surface of the crowns. For the mechanical tests of compressive and diametral tensile strength and shear bond strength a universal testing machine was used with a crosshead speed of 1,0 mm/min and for the Vickers microhardness analysis tests a Microdurometer was used with 200 g of load during 15 seconds. The results were submitted to statistical analysis through ANOVA complemented by Tukey's test at a significance level of 5%. RESULTS: The results shown that the Multi-Cure Glass Ionomer presented higher diametral tensile strength (p < 0.01) and compressive strength greater than conventional GICs (p = 0.08). Moreover, Ketac Cem showed significant less microhardness (p < 0.01). CONCLUSION: The resin-modified glass ionomer cement showed high mechanical properties, compared to the conventional glass ionomer cements, which had few differences between them.


Author(s):  
Valerie Bowser Fajen ◽  
Manville G. Duncanson ◽  
Ram S. Nanda ◽  
G. Frans Currier ◽  
Padmaraj V. Angolkar

Materials ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 6694
Author(s):  
Flavia Iaculli ◽  
Alessandro Salucci ◽  
Gianni Di Giorgio ◽  
Valeria Luzzi ◽  
Gaetano Ierardo ◽  
...  

Background: Conventional composites are largely used in pediatric restorative dentistry and demonstrate successful clinical outcomes. However, the need for simplification of operative steps in young or uncooperative children demands reliable alternatives. Therefore, the aim of the present systematic review and meta-analysis was to evaluate the in vitro bond strength of glass ionomer cements (GICs) and self-adhesive flowable composites (SFCs) on deciduous teeth. Methods: A comprehensive literature search according to the PRISMA checklist was manually and electronically performed by two independent reviewers through the following databases: MEDLINE/PubMed, Google Scholar, Scopus, and Embase, to include in vitro studies comparing GICs and SFCs bond strength values of restorations on primary teeth. In addition, three groups of meta-analyses were conducted using random-effects models. Results: Three articles meeting the inclusion criteria were selected and subjected to both qualitative and quantitative assessment. No statistically significant difference was found between SFC versus GIC; however, both groups significantly differed with conventional flowable composites (CFs). Conclusions: Despite the absence of significant difference in bond strength values, SFCs may be considered a valid alternative to GICs in the restoration of deciduous teeth, although CFs proved better in vitro performances.


2020 ◽  
Vol 8 (D) ◽  
pp. 112-117
Author(s):  
Ayah Atif Selim ◽  
Ahmed Fawzy Abo Elezz ◽  
Rehab Khalil Safy

AIM: Investigation of the aging effect on the microtensile bond strength (μTBS) of bulk-fill resin composite (RC) versus a conventionally incrementally applied one. MATERIALS AND METHODS: A total number of 45 sound human impacted third molars extracted molars have been selected to prepare specimens for the μTBS test. Teeth were randomly divided into three groups (C) according to type of RC material which used for restoring the teeth. Where nanohybrid RC (Grandio®SO) was used as the control Group (C1), packable bulk-fill RC (X-tra fil®) was used for restoring teeth in C2 group and flowable bulk-fill RC (X-tra base®) was used for restoring teeth in C3 group. Each group was further subdivided into 3 subgroups (n = 5) according to the water storage time, where in subgroup 1; teeth were stored for 24 h, subgroup 2; teeth were stored for 3 months while for subgroup 3; and teeth were stored for 6 months. After water storage, teeth were sectioned for preparation of μTBS testing beams. Maximum tensile stresses were recorded in megapascal (MPa). RESULTS: After 24 h of water storage, the X-tra base® showed a higher statistically significant μTBS to dentin (33.82 ± 9.84 MPa) than did the other two types of RCs. After 3 months, the X-tra fil® showed the lowest mean value of μTBS (10.90 ± 5.66 MPa), meanwhile, after 6 months of water storage Grandio®SO showed the highest mean value of μTBS (15.85 ± 6.76 MPa). Regardless of the time the X-tra fil® showed the lowest mean of μTBS (15.07 ± 11.73 MPa), while there is no significant difference between the X-tra base® and Grandio®SO. Furthermore, the water aging adversely affects μTBS values which deceased gradually by time. CONCLUSION: The packable bulk-fill RC characterized by lower μTBS to dentin in comparison to the flowable bulk fill and the incrementally applied nanohybrid RCs. Furthermore, the μTBS of the three tested materials decreased gradually by aging.


Sign in / Sign up

Export Citation Format

Share Document