Effect of polymerization methods and thermal cycling on color stability of acrylic resin denture teeth

2009 ◽  
Vol 102 (6) ◽  
pp. 385-392 ◽  
Author(s):  
Wirley Gonçalves Assunção ◽  
Valentim Adelino Ricardo Barão ◽  
Murillo Sucena Pita ◽  
Marcelo Coelho Goiato
2015 ◽  
Vol 113 (6) ◽  
pp. 628-635 ◽  
Author(s):  
Valentim Adelino Ricardo Barão ◽  
Erika Shiguematsu Ogawa ◽  
Amália Moreno ◽  
Marcelo Ferraz Mesquita ◽  
Alvin G. Wee ◽  
...  

2018 ◽  
Vol 8 (3) ◽  
pp. 117-122
Author(s):  
Hatice Özdemir ◽  
Zeynep Yeşil Duymuş

Aim: The aim of this study was to evaluate the effect of artificial saliva, disinfectant solution, distile water and thermocycling on Vickers hardness of 4 commercial brands of acrylic resin denture teeth. Methodology: Four different brands of acrylic resin denture teeth (Major Dent, Acry Lux, Acry Rock, Imident Lux) were evaluated. 15 anterior and 15 posterior teeth of each group embedded in autopolymerized acrylic resin.  The occlusal surfaces of posterior teeth and the vestibule surfaces of anterior teeth were flattened by using silicone carbid paper. After polishing, microhardness measurements were repeated three times for each teeth. The teeth were submitted to different conditions: (1) storage in distilled water at 37±2°C for 7 days; (2) storage in artificial saliva at 37±2°C for 30 days and (3) storage in 1 % sodium hypochlorite. After, thermal cycling between 5 and 55 °C for 2500 cycles was made. The microhardness measurements were repeated. Data were analyzed with one-way analysis of variance (ANOVA) and Duncan test ( p<0.05). Results: There was statistical significant differences between initial and final microhardness values of different barnds of acrylic resin denture teet. Anterior teeth showed lower microhardness values than posterior teeth. Conclusion: Storage in different solutions and thermal cycling significantly reduced the Vickers hardness of the acrylic resin denture teeth.


2017 ◽  
Vol 17 (04) ◽  
pp. 1750074
Author(s):  
MD ABU HASAN ◽  
PANOS S. SHIAKOLAS

This study compares the biomechanical behavior of a mandibular full-arch fixed implant prosthesis with four implants under lingualized and conventional balanced occlusion schemes. The acrylic resin denture was supported by four titanium cylindrical implants and connected via a titanium prosthetic rectangular bar. Orthotropic material was used for the cortical and cancellous bones. The applied loadings were vertical and bilateral: 100[Formula: see text]N on first molar and 50[Formula: see text]N on first and second premolars each. For the lingualized balanced occlusion, the loadings were applied in central fossae of the posterior teeth, whereas for the conventional balanced occlusion the loadings were applied in central fossae and buccal cusps. The maximum von-Mises stresses for the lingualized and conventional balanced schemes were 301[Formula: see text]MPa and 25[Formula: see text]MPa, respectively, and were located at the neck of the posterior implants. In the denture teeth, the highest stress was located at the beginning of the cantilever extension. In the cortical bone, according to Tsai–Wu criterion, the failure index for the lingualized balanced occlusion was 1.10 and for the conventional balanced occlusion was 0.83. Thus, the conventional balanced occlusion demonstrated more favorable stress distribution in the implants and the cortical bone than the lingualized balanced occlusion.


2010 ◽  
Vol 54 (3) ◽  
pp. 123-127 ◽  
Author(s):  
Wirley Gonçalves Assunção ◽  
Érica Alves Gomes ◽  
Valentim Adelino Ricardo Barão ◽  
Débora Barros Barbosa ◽  
Juliana Aparecida Delben ◽  
...  

2016 ◽  
Vol 27 (2) ◽  
pp. 169-176 ◽  
Author(s):  
Adaias O. Matos ◽  
Josiane O. Costa ◽  
Thamara Beline ◽  
Erika S. Ogawa ◽  
Wirley G. Assunção ◽  
...  

2018 ◽  
Vol 5 (4) ◽  
pp. 76
Author(s):  
Mone Laiz Bortoli ◽  
Cristina Von Appen ◽  
Camila Longoni ◽  
Carmen Beatriz Borges Fortes ◽  
Jefferson Tomio Sanada

Aim: This work aimed to evaluate the color stability of an acrylic resin chemically activated (ARCA) using different handling techniques, and a bisacrylic resin when exposed to different pigmentation solutions.Material and Methods: Silicon matrixes were confectioned (10x10x3mm) to be used as specimens. The groups were designed as follows: Group Pot, Group Brush, Group Manufacturer and Group Bisacrylic (n=18). Each group was exposed to three different pigmentation solutions: distilled water, coke and chlorhexidine digluconate 0.12%. Three readings were performed for each specimen using a spectrophotometer, and the evaluations were carried out in three different time. After the color reading, three averages and the standard deviation of variation were performed after 24 hours (T1), 7 days (T2) and 14 days (T3). Data were submitted to the ANOVA and 2 criteria and Tukey (P<0.05) in the statistical software SSPS 18 for Macintosh (SPSS Inc., Chicago, USA).Results: When compared the solutions in each group of material, there was no statistically significant difference, except for T3, where the group Dencor Brush and Bisacrylic demonstrated higher color variation in all the solutions, even in the control group, and the values in Chlorhexidine higher than the other, showing greater instability after 14 days.Conclusions: With the results, bisacrylic resin used as provisory prosthesis material presents greater color instability than the ARCA, when submitted to different solutions. Bisacrylic resin and Dencor Brush present significantly visible color changes in chlorhexidine solution after 14 days. All the materials in coke solution present homogeneity in the color change after 7 days exposition to the solution, with no visible color change.


2017 ◽  
Vol 11 (1) ◽  
pp. 57-64 ◽  
Author(s):  
Saja Ali Muhsin

Background: Although bonding to denture teeth after surface treatment with chemical agents is desirable, there is little information on the use of Visible Light Cure composite resin (VLC) as bonding denture materials. Objectives: To determine the effect of various surface treatments on shear bond strength between Visible Light Cure composite resin and the acrylic denture teeth interface. Methods: Forty cylindrical sticks of acrylic resin with denture teeth mounted atop were prepared. Various treatments were implemented upon the acrylic resin teeth surfaces. The samples were divided into four groups (n = 10). Light-cured composite resin (LC) was applied over all treated and untreated surfaces of tested groups. The shear bond was tested using a universal tensile testing apparatus with the knife-edge of a 0.8mm shear tester. Data were statistically analyzed using one-way ANOVA performed at a confidence level of 95% and significant P-value of (P ≤ 0.05). Results: Analysis of variance (ANOVA) showed statistically significant difference (P < 0.05) between treated and untreated teeth surfaces. The treated surfaces exhibited various levels of bond strength depending on the type of treatment. Conclusion: Application of VLC bonding agent with prior treatment of methylmethacrylate (MMA) on the acrylic resin denture teeth resulted in maximum bond strength with composite resin.


2013 ◽  
Vol 42 (4) ◽  
pp. 237-242 ◽  
Author(s):  
Ana Carolina Pero ◽  
Jaqueline Ignárcio ◽  
Gabriela Giro ◽  
Danny Omar Mendoza-Marin ◽  
André Gustavo Paleari ◽  
...  

INTRODUCTION: The occurrence of stomatitis is common since the surface characteristics of the dentures may act as reservoirs for microorganisms and have the potential to support biofilm formation. PURPOSE: To assess the surface properties (wettability/roughness) and color stability of an acrylic resin combined with the antimicrobial polymer poly (2-tert-butylaminoethyl) methacrylate (PTBAEMA). MATERIAL AND METHOD: Thirty disc-shaped specimens of an acrylic resin (Lucitone 550) were divided into three groups: 0% (control); 5% and 10% PTBAEMA. Surface roughness values (Ra) were measured using a profilometer and wettability was determined through contact angle measurements using a goniometer and deionized water as a test liquid. Color data were measured with a spectrophotometer. Kruskal-Wallis and Dunn's test were used to compare roughness values. Wettability data were analyzed using ANOVA and Tukey's test. Color data were compared using the Student's t-test and ∆E values were classified according to the National Bureau of Standards (NBS). All statistical analyses were performed considering α=.05. RESULT: Significant differences (p<.05) were detected among the groups for roughness, wettability and color stability. According to the NBS, the color changes obtained in the 5% and 10% PTBAEMA groups were "appreciable" and "much appreciable", respectively. CONCLUSION: It could be concluded that PTBAEMA incorporation in an acrylic resin increased the roughness and wettability of surfaces and produced color changes with clinical relevance.