Advanced regeneration and fixed-bed study of ammonium and potassium removal from anaerobic digested wastewater by natural zeolite

2013 ◽  
Vol 25 (5) ◽  
pp. 954-961 ◽  
Author(s):  
Xuejun Guo ◽  
Larry Zeng ◽  
Xin Jin
2012 ◽  
Vol 518-523 ◽  
pp. 3115-3119
Author(s):  
Yan Qiang Li ◽  
Xiao Feng Ren ◽  
Shao Hua Chen ◽  
Xiu Rong Zhao ◽  
Run Ping Han

The effect of bed depth on adsorption ability of natural zeolite to removal methylene blue (MB) from aqueous solution in the fixed-bed column was studied. The results showed that the increase in column height favored the MB removal form solution. The equilibrium uptake of MB onto unit mass zeolite increased with the bed depth growth. The experimental data were fitted to Yan model using linear and nonlinear regression analysis, respectively. The experimental points and the predicted curves using the Yan model were compared and the error analysis was performed. The results indicated that Yan model were good to predict the breakthrough curves and both two methods can be used to obtain the parameters of Yan model and to predict the breakthrough curves.


Clay Minerals ◽  
2015 ◽  
Vol 50 (1) ◽  
pp. 91-101 ◽  
Author(s):  
I. Nuić ◽  
M. Trgo ◽  
J. Perić ◽  
N. Vukojević Medvidović

AbstractThe removal of lead and zinc from a binary solution by fixed bed depths (40, 80 and 120 mm) of a natural zeolite was examined at a flow rate of 1 mL/min. The results obtained were fitted to the Bed Depth Service Time (BDST) model and the parameters of the model (q and k) were used to design a column system for flow rates of 2 and 3 mL/min at a bed depth of 80 mm. The experimental results were in excellent agreement with those predicted and experimental breakthrough curves for the binary systems were obtained. This approach facilitates the design of effective binary column processes without additional experimentation. Two major design parameters, the Empty Bed Contact Time (EBCT) and the zeolite usage rate, were calculated. The highest EBCT value of 13.56 min represents the optimal conditions for the binary (Pb+Zn) solution.


2021 ◽  
Author(s):  
Amanda L. Ciosek ◽  
Grace K. Luk

This study investigates the design and performance of a novel sorption system containing natural zeolite. The apparatus consists of packed, fixed-bed, dual-columns with custom automated controls and sampling chambers, connected in series and stock fed by a metering pump at a controlled adjustable distribution. The purpose of the system is to remove heavy metallic ions predominately found in acid mine drainage, including lead (Pb2+), copper (Cu2+), iron (Fe3+), nickel (Ni2+) and zinc (Zn2+), combined in equal equivalence to form an acidified total 10 meq/L aqueous solution. Reported trends on the zeolite’s preference to these heavy metallic ions is established in the system breakthrough curve, as Pb2+ >> Fe3+ > Cu2+ > Zn2+ >> Ni2+. Within a 3-h contact period, Pb2+ is completely removed from both columns. Insufficient Ni2+ removal is achieved by either column with the promptest breakthrough attained, as zeolite demonstrates the least affinity towards it; however, a 48.97% removal is observed in the cumulative collection at the completion of the analysis period. The empty bed contact times for the first and second columns are 20 and 30 min, respectively; indicating a higher bed capacity at breakthrough and a lower usage rate of the zeolite mineral in the second column. This sorption system experimentally demonstrates the potential for industrial wastewater treatment technology development. Keywords: zeolite; sorption; packed fixed-bed columns; heavy metallic ions; automated sampling design


Desalination ◽  
2007 ◽  
Vol 215 (1-3) ◽  
pp. 133-142 ◽  
Author(s):  
Marinos A. Stylianou ◽  
Vasilis J. Inglezakis ◽  
Konstantinos G. Moustakas ◽  
Simos Ph. Malamis ◽  
Maria D. Loizidou

2009 ◽  
Vol 44 (2) ◽  
pp. 146-154 ◽  
Author(s):  
S. Nikolaeva ◽  
E. Sánchez ◽  
R. Borja ◽  
F. Raposo ◽  
M. F. Colmenarejo ◽  
...  

2016 ◽  
Vol 122 ◽  
pp. 282-288 ◽  
Author(s):  
Hyung Won Lee ◽  
Young-Min Kim ◽  
Jungho Jae ◽  
Bong Hyun Sung ◽  
Sang-Chul Jung ◽  
...  

2015 ◽  
Vol 5 (4) ◽  
pp. 542-549 ◽  
Author(s):  
Waid S. Omar

The potential of natural zeolite as a low-cost adsorbent was investigated for the removal of zinc from aqueous solution using a continuous fixed bed column. The zeolite tested was taken from the same source (Jabal Uniza in south Jordan) and subjected to crushing and sieving only, without any treatment. The two samples tested are UNZ1 (0.42–0.841 mm) and UNZ2 (0.21–0.42 mm). The Thomas model analysis of the measured breakthrough curves revealed that the adsorbent UNZ2 has a higher value of adsorption capacity to zinc ions (50.75 mg/g) than UNZ1 (33.68 mg/g). The time to 50% breakthrough was determined by the Yoon and Nelson model. It has been found that the time needed to reach 50% breakthrough is 2,006 minutes and 3,171 minutes for UNZ1 and UNZ2, respectively. This indicated that UNZ2 provides better performance with larger service time. Both UNZ1 and UNZ2 agreed to a high degree with the Thomas and Yoon and Nelson models.


Sign in / Sign up

Export Citation Format

Share Document