lead removal
Recently Published Documents


TOTAL DOCUMENTS

535
(FIVE YEARS 195)

H-INDEX

42
(FIVE YEARS 8)

Chemosphere ◽  
2022 ◽  
Vol 287 ◽  
pp. 132016
Author(s):  
Deen Dayal Giri ◽  
Alaa Alhazmi ◽  
Akbar Mohammad ◽  
Shafiul Haque ◽  
Neha Srivastava ◽  
...  

Molecules ◽  
2021 ◽  
Vol 26 (24) ◽  
pp. 7550
Author(s):  
Tussaneetorn Chuenpratoom ◽  
Khuanjit Hemavibool ◽  
Kritsana Rermthong ◽  
Suwat Nanan

This study introduces a merlinoite synthesized from sugarcane bagasse ash (SBA) and kaolin and evaluates its application as an adsorbent to remove lead from wastewater. The synthesis was performed via the hydrothermal method, and optimal conditions were determined. The adsorption of Pb by merlinoite was also optimized. Determination of the Pb2+ remaining in the aqueous solution was determined by atomic absorption spectroscopy (AAS). Adsorption isotherms were mainly studied using the Langmuir and Freundlich models. The Langmuir model showed the highest consistency for Pb adsorption on merlinoite, yielding a high correlation coefficient (R2) of 0.9997 and a maximum adsorption capacity (qmax) of 322.58 mg/g. The kinetics of the adsorption process were best described by a pseudo-second-order model. Thermodynamic studies carried out at different temperatures established that the adsorption reaction was spontaneous and endothermic. The results of this study show that merlinoite synthesized from kaolinite and SBA is an excellent candidate for utilization as a high-performance adsorbent for lead removal from wastewater.


Author(s):  
Zygmunt Mariusz Gusiatin ◽  
Jurate Kumpiene ◽  
Ivan Carabante ◽  
Maja Radziemska ◽  
Martin Brtnicky

This paper presents experimental results from the use of biosurfactants in the remediation of a soil from a smelter in Poland. In the soil, concentrations of Cu (1659.1 mg/kg) and Pb (290.8 mg/kg) exceeded the limit values. Triple batch washing was tested as a soil treatment. Three main variants were used, each starting with a different plant-derived (saponin, S; tannic acid, T) or microbial (rhamnolipids, R) biosurfactant solution in the first washing, followed by 9 different sequences using combinations of the tested biosurfactants (27 in total). The efficiency of the washing was determined based on the concentration of metal removed after each washing (CR), the cumulative removal efficiency (Ecumulative) and metal stability (calculated as the reduced partition index, Ir, based on the metal fractions from BCR sequential extraction). The type of biosurfactant sequence influenced the CR values. The variants that began with S and R had the highest average Ecumulative for Cu and Pb, respectively. The Ecumulative value correlated very strongly (r > 0.8) with the stability of the residual metals in the soil. The average Ecumulative and stability of Cu were the highest, 87.4% and 0.40, respectively, with the S-S-S, S-S-T, S-S-R and S-R-T sequences. Lead removal and stability were the highest, 64–73% and 0.36–0.41, respectively, with the R-R-R, R-R-S, R-S-R and R-S-S sequences. Although the loss of biosurfactants was below 10% after each washing, sequential washing with biosurfactants enriched the soil with external organic carbon by an average of 27-fold (S-first variant), 24-fold (R first) or 19-fold (T first). With regard to environmental limit values, metal stability and organic carbon resources, sequential washing with different biosurfactants is a beneficial strategy for the remediation of smelter-contaminated soil with given properties.


2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Federico Migliore ◽  
Vincenzo Tarzia ◽  
Pietro Bernardo Dall’Aglio ◽  
Pasquale Valerio Falzone ◽  
Sabino Iliceto ◽  
...  

Abstract Aims Recent studies have shown that evolution RL bidirectional rotational mechanical sheath (Cook Medical, USA) is an effective and safe technique for transvenous lead extraction (TLE). We reported our experience with the bidirectional rotational mechanical tools using a multidisciplinary approach highlighting the value of a joint cardiac surgeon and electrophysiologist collaboration. Methods and results The study population comprised 84 patients (77% male; mean age 65 ± 18 years) undergoing TLE. After multidisciplinary evaluation, a combined procedure was considered. The main indication for TLE was infection in 54 cases (64%).Overall, 152 leads were extracted with a mean implant duration of 94 ± 63 months (range: 6–421). Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 91.6% (77/84), 97.6% (82/84), and 98.6% (150/152), respectively. Eighteen combined procedures were performed in 12 patients (14%), such as ‘hybrid approach’ (n = 2) or TLE concomitant to: (i) transcatheter aspiration procedure for large vegetation (n = 8); (ii) left ventricular assistance device implantation as bridge to cardiac transplantation (n = 1); (iii) permanent pacing with epicardial leads (n = 6); and (iv) tricuspid valve replacement (n = 1).One major complication (1.2%) and 11 (13%) minor complications were encountered. No injury to the superior vena cava occurred and no procedure-related deaths were reported. During a mean time follow-up of 21 ± 18 months, 17 patients (20%) died. They were more often diabetics (P = 0.02), and they underwent TLE more often for infection (P = 0.004). Conclusions Our results support the finding that excellent outcomes can be achieved in performing TLE of chronically implanted leads by using the evolution RL bidirectional rotational mechanical sheath and a multidisciplinary team approach involving both electrophysiologist and cardiac surgeon as first line operators.


Heart Rhythm ◽  
2021 ◽  
Author(s):  
Justin Z. Lee ◽  
Monil Majmundar ◽  
Ashish Kumar ◽  
Samarthkumar Thakkar ◽  
Harsh P. Patel ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Majid Ehteshami ◽  
Hamidreza Zolfaghari ◽  
Marjan Salari ◽  
Ehsan Teymouri

Today, most countries around the globe are facing water resources restrictions, and it is predicted freshwater resources will be more valuable than oil wells in the next century. In the present study, the ability of lead removal using both powders of Mespilus germanica (MG) and Tribulus terrestris (TT) seeds and optimization of the adsorption process have been investigated. Four main parameters were selected for experimental design, namely, pH, time of contact, the ratio of adsorbent to solution volume, and initial concentration of lead in solution, and the optimization of effective parameters on lead adsorption was performed based on central composite design (CCD) under response surface methodology (RSM). According to the statistical results, the proposed model for MG and TT is confirmed with 0.95 and 0.96 correlation coefficient and 0.92 and 0.94 adjusted correlation coefficient, respectively. The results of parameter optimization also showed that both adsorbents have the acceptable ability to adsorb lead from aqueous solutions. Under the optimum conditions with the initial lead concentration of 10 mg/l, MG powder had better performance in lead adsorption of 96.04%, and TT powder also had an acceptive performance of 93.20%. Moreover, the MG and TT adsorbents have the most accordance with the Freundlich and D-R isotherms, respectively.


Author(s):  
Sun Yong Lee ◽  
Isabel E. Allen ◽  
Celso Diaz ◽  
Xiaofan Guo ◽  
Cara Pellegrini ◽  
...  

Abstract Background Rotating and laser sheaths are both routinely used in transvenous lead extraction (TLE) which can lead to catastrophic complications including death. The efficacy and risk of each approach are uncertain. To perform a meta-analysis to compare success and mortality rates associated with rotating and laser sheaths. Methods We searched electronic academic databases for case series of consecutive patients and randomized controlled trials published 1998–2017 describing the use of rotating and laser sheaths for TLE. Among 48 studies identified, rotating sheaths included 1,094 patients with 1,955 leads in 14 studies, and laser sheaths included 7,775 patients with 12,339 leads in 34 studies. Patients receiving rotating sheaths were older (63 versus 60 years old) and were more often male (74% versus 72%); CRT-P/Ds were more commonly extracted using rotating sheaths (12% versus 7%), whereas ICDs were less common (37% versus 42%), p > 0.05 for all. Infection as an indication for lead extraction was higher in the rotating sheath group (59.8% versus 52.9%, p = 0.002). The mean time from initial lead implantation was 7.2 years for rotating sheaths and 6.3 years for laser sheaths (p > 0.05). Results Success rates for complete removal of transvenous leads were 95.1% in rotating sheaths and 93.4% in laser sheaths (p < 0.05). There was one death among 1,094 patients (0.09%) in rotating sheaths and 66 deaths among 7,775 patients (0.85%) in laser sheaths, translating to a 9.3-fold higher risk of death with laser sheaths (95% CI 1.3 to 66.9, p = 0.01). Conclusions Laser sheaths were associated with lower complete lead removal rate and a 9.3-fold higher risk of death.


2021 ◽  
Vol 910 (1) ◽  
pp. 012136
Author(s):  
Hazim Aziz Al-Robai ◽  
Ameer Hazim Azeez Al-Rubay ◽  
Ghaith Salah Al-Mamoori ◽  
Ali Akram Abdulateef

Abstract The soil washing technique is considered one of the quick and effective techniques for treating soil contaminated with heavy metals. In this study, EDTA-Na2 and Oxalic were used as washing solutions to removing Pb from calcareous and gypsum soils contaminated with Pb only and with Pb in addition to the used engine oil. The soil samples were contaminated with different concentrations of Pb only using Pb(NO3)2 to soils sample for each concentration separately then the sample was divided into two equal parts. The first part represents the calcareous and gypsum soil samples contaminated with Pb. The second part was taken after air-dried, and then the used engine oil was added and homogenized well. Five parameters (pH, contact time, Pb concentrations, temperature, and liquid/solid ratio) were applied to test their effect on Pb removal. In general, the results of this study varied based on the effect of the variables.


Sign in / Sign up

Export Citation Format