Ultraviolet-C (UV-C) monitoring made simple: Colorimetric indicators to assess delivery of UV-C light by room decontamination devices

Author(s):  
Jennifer L. Cadnum ◽  
Basya S. Pearlmutter ◽  
Sarah N. Redmond ◽  
Annette L. Jencson ◽  
Kevin J. Benner ◽  
...  

Abstract Objective: To evaluate the use of colorimetric indicators for monitoring ultraviolet-C (UV-C) light delivery to sites in patient rooms. Methods: In laboratory testing, we examined the correlation between changes in color of 2 commercial colorimetric indicators and log10 reductions in methicillin-resistant Staphylococcus aureus (MRSA) and Clostridioides difficile spores with exposure to increasing doses of UV-C from a low-pressure mercury room decontamination device. In patient rooms, 1 of the colorimetric indicators was used to assess UV-C dose delivery to 27 sites in the room. Results: In laboratory testing, the manufacturer’s reference colors for MRSA and C. difficile reduction corresponded with doses of ∼10,000 and 46,000 µJ/cm2; these doses resulted in >3 log10 reductions in MRSA and C. difficile spores, respectively. In patient rooms, the colorimetric indicators demonstrated suboptimal delivery of UV-C dosing to shadowed areas, which was improved by providing cycles on each side of the patient bed rather than in a single position and altering device placement. Increasing duration of exposure increased the number of sites achieving adequate dosing to kill C. difficile spores. Conclusions: Commercial colorimetric indicators provide rapid and easy-to-interpret information on the UV-C dose delivered to sites in patient rooms. The indicators may be useful for training environmental services personnel and optimizing the effectiveness of UV-C room decontamination devices.

2017 ◽  
Vol 39 (1) ◽  
pp. 94-96 ◽  
Author(s):  
Jennifer L. Cadnum ◽  
Aaron A. Shaikh ◽  
Christina T. Piedrahita ◽  
Annette L. Jencson ◽  
Emily L. Larkin ◽  
...  

Mobile ultraviolet-C (UV-C) light room decontamination devices are frequently used as an adjunct to standard cleaning in healthcare facilities, but their efficacy in killing Candida species is not clear. In laboratory testing, the emerging multidrug-resistant Candida auris and 2 other Candida species were significantly less susceptible to killing by UV-C than methicillin-resistant Staphylococcus aureus.Infect Control Hosp Epidemiol 2018;39:94–96


Author(s):  
Hanan Haydar ◽  
Jessica A Kumar ◽  
Jennifer L Cadnum ◽  
Emily Zangla ◽  
Claudia K Hoyen ◽  
...  

Abstract No-touch technologies could be useful to decontaminate shared toys in healthcare settings. A high-level disinfection cSabinet and electrostatic sprayer were effective against methicillin-resistant Staphylococcus aureus (MRSA), bacteriophage MS2, and Clostridioides difficile spores on toys. An ultraviolet-C light box was less effective but reduced MRSA and bacteriophage MS2 by >2 log10.


2013 ◽  
Vol 34 (5) ◽  
pp. 527-529 ◽  
Author(s):  
William A. Rutala ◽  
Maria F. Gergen ◽  
Brian M. Tande ◽  
David J. Weber

We tested the ability of an ultraviolet C (UV-C)–reflective wall coating to reduce the time necessary to decontaminate a room using a UV-C-emitting device (Tru-D SmartUVC). The reflective wall coating provided the following time reductions for decontamination: for methicillin-resistant Staphylococcus aureus, from 25 minutes 13 seconds to 5 minutes 3 seconds (P < .05), and for Clostridium difficile spores, from 43 minutes 42 seconds to minutes 24 seconds (P < .05).


2020 ◽  
Vol 41 (S1) ◽  
pp. s33-s33
Author(s):  
Michihiko Goto ◽  
Erin Balkenende ◽  
Gosia Clore ◽  
Rajeshwari Nair ◽  
Loretta Simbartl ◽  
...  

Background: Enhanced terminal room cleaning with ultraviolet C (UVC) disinfection has become more commonly used as a strategy to reduce the transmission of important nosocomial pathogens, including Clostridioides difficile, but the real-world effectiveness remains unclear. Objectives: We aimed to assess the association of UVC disinfection during terminal cleaning with the incidence of healthcare-associated C. difficile infection and positive test results for C. difficile within the nationwide Veterans Health Administration (VHA) System. Methods: Using a nationwide survey of VHA system acute-care hospitals, information on UV-C system utilization and date of implementation was obtained. Hospital-level incidence rates of clinically confirmed hospital-onset C. difficile infection (HO-CDI) and positive test results with recent healthcare exposures (both hospital-onset [HO-LabID] and community-onset healthcare-associated [CO-HA-LabID]) at acute-care units between January 2010 and December 2018 were obtained through routine surveillance with bed days of care (BDOC) as the denominator. We analyzed the association of UVC disinfection with incidence rates of HO-CDI, HO-Lab-ID, and CO-HA-LabID using a nonrandomized, stepped-wedge design, using negative binomial regression model with hospital-specific random intercept, the presence or absence of UVC disinfection use for each month, with baseline trend and seasonality as explanatory variables. Results: Among 143 VHA acute-care hospitals, 129 hospitals (90.2%) responded to the survey and were included in the analysis. UVC use was reported from 42 hospitals with various implementation start dates (range, June 2010 through June 2017). We identified 23,021 positive C. difficile test results (HO-Lab ID: 5,014) with 16,213 HO-CDI and 24,083,252 BDOC from the 129 hospitals during the study period. There were declining baseline trends nationwide (mean, −0.6% per month) for HO-CDI. The use of UV-C had no statistically significant association with incidence rates of HO-CDI (incidence rate ratio [IRR], 1.032; 95% CI, 0.963–1.106; P = .65) or incidence rates of healthcare-associated positive C. difficile test results (HO-Lab). Conclusions: In this large quasi-experimental analysis within the VHA System, the enhanced terminal room cleaning with UVC disinfection was not associated with the change in incidence rates of clinically confirmed hospital-onset CDI or positive test results with recent healthcare exposure. Further research is needed to understand reasons for lack of effectiveness, such as understanding barriers to utilization.Funding: NoneDisclosures: None


2013 ◽  
Vol 34 (5) ◽  
pp. 466-471 ◽  
Author(s):  
Deverick J. Anderson ◽  
Maria F. Gergen ◽  
Emily Smathers ◽  
Daniel J. Sexton ◽  
Luke F. Chen ◽  
...  

Objective.To determine the effectiveness of an automated ultraviolet-C (UV-C) emitter against vancomycin-resistant enterococci (VRE),Clostridium difficile, andAcinetobacterspp. in patient rooms.Design.Prospective cohort study.Setting.Two tertiary care hospitals.Participants.Convenience sample of 39 patient rooms from which a patient infected or colonized with 1 of the 3 targeted pathogens had been discharged.Intervention.Environmental sites were cultured before and after use of an automated UV-C-emitting device in targeted rooms but before standard terminal room disinfection by environmental services.Results.In total, 142 samples were obtained from 27 rooms of patients who were colonized or infected with VRE, 77 samples were obtained from 10 rooms of patients withC. difficileinfection, and 10 samples were obtained from 2 rooms of patients with infections due toAcinetobacter. Use of an automated UV-C-emitting device led to a significant decrease in the total number of colony-forming units (CFUs) of any type of organism (1.07 log10reduction;P< .0001), CFUs of target pathogens (1.35 log10reduction;P< .0001), VRE CFUs (1.68 log10reduction;P< .0001), and C.difficileCFUs (1.16 log10reduction;P< .0001). CFUs ofAcinetobacteralso decreased (1.71 log10reduction), but the trend was not statistically significantP= .25). CFUs were reduced at all 9 of the environmental sites tested. Reductions similarly occurred in direct and indirect line of sight.Conclusions.Our data confirm that automated UV-C-emitting devices can decrease the bioburden of important pathogens in real-world settings such as hospital rooms.


2020 ◽  
Vol 11 ◽  
Author(s):  
Sara A. Ochoa ◽  
Ariadnna Cruz-Córdova ◽  
Jetsi Mancilla-Rojano ◽  
Gerardo Escalona-Venegas ◽  
Veronica Esteban-Kenel ◽  
...  

Methicillin-resistant Staphylococcus aureus (MRSA) is considered an opportunistic pathogen in humans and is mainly associated with healthcare-associated infections (HCAIs). This bacterium colonizes the skin and mucous membranes of healthy people and causes frequent hospital outbreaks. The aim of this study was to perform molecular typing of the staphylococcal cassette chromosome mec (SCCmec) and agr loci as wells as to establish the pulsotypes and clonal complexes (CCs) for MRSA and methicillin-sensitive S. aureus (MSSA) outbreaks associated with the operating room (OR) at a pediatric hospital. Twenty-five clinical strains of S. aureus (19 MRSA and 6 MSSA strains) were recovered from the outbreak (patients, anesthesia equipment, and nasopharyngeal exudates from external service anesthesia technicians). These clinical S. aureus strains were mainly resistant to benzylpenicillin (100%) and erythromycin (84%) and were susceptible to vancomycin and nitrofurantoin. The SCCmec type II was amplified in 84% of the S. aureus strains, and the most frequent type of the agr locus was agrII, which was amplified in 72% of the strains; however, the agrI and agrIII genes were mainly detected in MSSA strains. A pulsed-field gel electrophoresis (PFGE) analysis grouped the 25 strains into 16 pulsotypes (P), the most frequent of which was P1, including 10 MRSA strains related to the anesthesia equipment, external service anesthesia technicians, and hospitalized patients. Multilocus sequence typing (MLST) identified 15 sequence types (STs) distributed in nine CCs. The most prevalent ST was ST1011, belonging to CC5, which was associated with the SCCmec type II and agrII type. We postulate that the external service anesthesia technicians were MRSA carriers and that these strains were indirectly transmitted from the contaminated anesthesia equipment that was inappropriately disinfected. Finally, the MRSA outbreak was controlled when the anesthesia equipment disinfection was improved and hand hygiene was reinforced.


2016 ◽  
Vol 37 (6) ◽  
pp. 667-672 ◽  
Author(s):  
John M. Boyce ◽  
Patricia A. Farrel ◽  
Dana Towle ◽  
Renee Fekieta ◽  
Michael Aniskiewicz

OBJECTIVETo evaluate ultraviolet C (UV-C) irradiance, UV-C dosage, and antimicrobial effect achieved by a mobile continuous UV-C device.DESIGNProspective observational study.METHODSWe used 6 UV light sensors to determine UV-C irradiance (W/cm2) and UV-C dosage (µWsec/cm2) at various distances from and orientations relative to the UV-C device during 5-minute and 15-minute cycles in an ICU room and a surgical ward room. In both rooms, stainless-steel disks inoculated with methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores were placed next to sensors, and UV-C dosages and log10 reductions of target organisms achieved during 5-minute and 15-minute cycles were determined. Mean irradiance and dosage readings were compared using ANOVA.RESULTSMean UV-C irradiance was nearly 1.0E-03 W/cm2 in direct sight at a distance of 1.3 m (4 ft) from the device but was 1.12E-05 W/cm2 on a horizontal surface in a shaded area 3.3 m (10 ft) from the device (P<.001). Mean UV-C dosages received by UV-C sensors located at different distances and orientation relative to the device varied significantly during 5-minute cycles and during 15-minute cycles (P<.001). Log10 reductions ranged from >4 to 1–3 for MRSA, >4 to 1–2 for VRE and >4 to 0 log10 for C. difficile spores, depending on the distance from, and orientation relative to, the device with 5-minute and 15-minute cycles.CONCLUSIONUV-C irradiance, dosage, and antimicrobial effect received from a mobile UV-C device varied substantially based on location in a room relative to the UV-C device.Infect Control Hosp Epidemiol 2016;37:667–672


2015 ◽  
Vol 36 (10) ◽  
pp. 1226-1228 ◽  
Author(s):  
Myreen E. Tomas ◽  
Jennifer L. Cadnum ◽  
Annette Jencson ◽  
Curtis J. Donskey

A portable booth designed to disinfect full-body coverage protective equipment before removal using ultraviolet-C radiation resulted in at least 3 log reductions in bacteriophage MS2 and methicillin-resistant Staphylococcus aureus within 3 minutes. The booth could be useful for disinfection of contaminated protective equipment before removal during care of Ebola patients.Infect Control Hosp Epidemiol 2015;36(10):1226–1228


2017 ◽  
Vol 56 (1) ◽  
Author(s):  
Bradley A. Ford

ABSTRACT Previously there was scant data on the performance of laboratory testing to detect mecC-mediated beta-lactam resistance in Staphylococcus aureus. Kriegeskorte and colleagues (J Clin Microbiol 56:e00826-17, 2018, https://doi.org/10.1128/JCM.00826-17) report the performance of various clinical tests for the detection of mecC-harboring methicillin-resistant S. aureus (MRSA), which failed to identify from 0 to 41% of tested mecC-harboring MRSA isolates. Changes in practice and new test development are necessary to address the challenge of mecC-harboring MRSA.