A light optical diffractometer for electron microscopical images operating in line

Author(s):  
P. Bonhomme ◽  
A. Beorchia

We have already described (1.2.3) a device using a pockel's effect light valve as a microscopical electron image converter. This converter can be read out with incoherent or coherent light. In the last case we can set in line with the converter an optical diffractometer. Now, electron microscopy developments have pointed out different advantages of diffractometry. Indeed diffractogram of an image of a thin amorphous part of a specimen gives information about electron transfer function and a single look at a diffractogram informs on focus, drift, residual astigmatism, and after standardizing, on periods resolved (4.5.6). These informations are obvious from diffractogram but are usualy obtained from a micrograph, so that a correction of electron microscope parameters cannot be realized before recording the micrograph. Diffractometer allows also processing of images by setting spatial filters in diffractogram plane (7) or by reconstruction of Fraunhofer image (8). Using Electrotitus read out with coherent light and fitted to a diffractometer; all these possibilities may be realized in pseudoreal time, so that working parameters may be optimally adjusted before recording a micrograph or before processing an image.

Author(s):  
Arthur J. Saffir ◽  
Tyler A. Woolley ◽  
Nelson Yew

The secondary electron image of the scanning electron microscope is similar to a light image of a three dimensional specimen. These two forms of "illumination", light and secondary electrons, have in common a contrast characteristic that makes photography or SEM micrography difficult. .. a tendency toward extreme highlights. The photographer encounters this phenomenon if his subject has a shiny surface, e.g., an automobile bumper. He overcomes this problem with dulling spray to suppress the undesirable highlights (reflections).This problem is also common in SEM studies, especially with biological specimens of poor conductivity. It is undesirable or impossible to subject thermolabile or living specimens to the deposition of conductive coatings.


Author(s):  
Linda M. Stannard ◽  
Margaret Lennon

Burnupena cincta and Fusus verruculatus are two whelks which inhabit the intertidal zones of the Cape Peninsula shore. Their respiratory pigments, or haemocyanins, are morphologically similar in structure (Figs. 1 and 2) and appear in the electron microscope as short cylindrical rods about 34 nm in diameter and 36 nm high. Viewed side-on the molecules show regular banding suggesting a structure composed of six equidistant rings of sub-units. Occasionally the particles have the appearance of possessing a central “belt” in the position of the 3rd and 4th rows of sub-units. End-on views of the haemocyanin molecules show a circular contour with a dense outer ring and a less dense inner ring in which 10 definite sub-units may frequently be distinguished. A number of molecules display an extra central inner component which appears either as a diffuse plug or as a discrete ring-shaped core ± 8 nm in diameter.


Author(s):  
O.C. de Hodgins ◽  
K. R. Lawless ◽  
R. Anderson

Commercial polyimide films have shown to be homogeneous on a scale of 5 to 200 nm. The observation of Skybond (SKB) 705 and PI5878 was carried out by using a Philips 400, 120 KeV STEM. The objective was to elucidate the structural features of the polymeric samples. The specimens were spun and cured at stepped temperatures in an inert atmosphere and cooled slowly for eight hours. TEM micrographs showed heterogeneities (or nodular structures) generally on a scale of 100 nm for PI5878 and approximately 40 nm for SKB 705, present in large volume fractions of both specimens. See Figures 1 and 2. It is possible that the nodulus observed may be associated with surface effects and the structure of the polymers be regarded as random amorphous arrays. Diffraction patterns of the matrix and the nodular areas showed different amorphous ring patterns in both materials. The specimens were viewed in both bright and dark fields using a high resolution electron microscope which provided magnifications of 100,000X or more on the photographic plates if desired.


Author(s):  
Cecil E. Hall

The visualization of organic macromolecules such as proteins, nucleic acids, viruses and virus components has reached its high degree of effectiveness owing to refinements and reliability of instruments and to the invention of methods for enhancing the structure of these materials within the electron image. The latter techniques have been most important because what can be seen depends upon the molecular and atomic character of the object as modified which is rarely evident in the pristine material. Structure may thus be displayed by the arts of positive and negative staining, shadow casting, replication and other techniques. Enhancement of contrast, which delineates bounds of isolated macromolecules has been effected progressively over the years as illustrated in Figs. 1, 2, 3 and 4 by these methods. We now look to the future wondering what other visions are waiting to be seen. The instrument designers will need to exact from the arts of fabrication the performance that theory has prescribed as well as methods for phase and interference contrast with explorations of the potentialities of very high and very low voltages. Chemistry must play an increasingly important part in future progress by providing specific stain molecules of high visibility, substrates of vanishing “noise” level and means for preservation of molecular structures that usually exist in a solvated condition.


Author(s):  
J. D. Hutchison

When the transmission electron microscope was commercially introduced a few years ago, it was heralded as one of the most significant aids to medical research of the century. It continues to occupy that niche; however, the scanning electron microscope is gaining rapidly in relative importance as it fills the gap between conventional optical microscopy and transmission electron microscopy.IBM Boulder is conducting three major programs in cooperation with the Colorado School of Medicine. These are the study of the mechanism of failure of the prosthetic heart valve, the study of the ultrastructure of lung tissue, and the definition of the function of the cilia of the ventricular ependyma of the brain.


Author(s):  
Lawrence W. Ortiz ◽  
Bonnie L. Isom

A procedure is described for the quantitative transfer of fibers and particulates collected on membrane filters to electron microscope (EM) grids. Various Millipore MF filters (Millipore AA, HA, GS, and VM; 0.8, 0.45, 0.22 and 0.05 μm mean pore size) have been used with success. Observed particle losses have not been size dependent and have not exceeded 10%. With fibers (glass or asbestos) as the collected media this observed loss is approximately 3%.


Author(s):  
E. U. Lee ◽  
P. A. Garner ◽  
J. S. Owens

Evidence for ordering (1-6) of interstitial impurities (O and C) has been obtained in b.c.c. metals, such as niobium and tantalum. In this paper we report the atomic and microstructural changes in an oxygenated c.p.h. metal (alpha titanium) as observed by transmission electron microscopy and diffraction.Oxygen was introduced into zone-refined iodide titanium sheets of 0.005 in. thickness in an atmosphere of oxygen and argon at 650°C, homogenized at 800°C and furnace-cooled in argon. Subsequently, thin foils were prepared by electrolytic polishing and examined in a JEM-7 electron microscope, operated at 100 KV.


Author(s):  
J. L. Farrant ◽  
J. D. McLean

For electron microscope techniques such as ferritin-labeled antibody staining it would be advantageous to have available a simple means of thin sectioning biological material without subjecting it to lipid solvents, impregnation with plastic monomers and their subsequent polymerization. With this aim in view we have re-examined the use of protein as an embedding medium. Gelatin which has been used in the past is not very satisfactory both because of its fibrous nature and the high temperature necessary to keep its solutions fluid. We have found that globular proteins such as the serum and egg albumins can be cross-linked so as to yield blocks which are suitable for ultrathin sectioning.


Author(s):  
H. Koike ◽  
S. Sakurai ◽  
K. Ueno ◽  
M. Watanabe

In recent years, there has been increasing demand for higher voltage SEMs, in the field of surface observation, especially that of magnetic domains, dislocations, and electron channeling patterns by backscattered electron microscopy. On the other hand, the resolution of the CTEM has now reached 1 ∼ 2Å, and several reports have recently been made on the observation of atom images, indicating that the ultimate goal of morphological observation has beem nearly achieved.


Author(s):  
S. Takashima ◽  
H. Hashimoto ◽  
S. Kimoto

The resolution of a conventional transmission electron microscope (TEM) deteriorates as the specimen thickness increases, because chromatic aberration of the objective lens is caused by the energy loss of electrons). In the case of a scanning electron microscope (SEM), chromatic aberration does not exist as the restrictive factor for the resolution of the transmitted electron image, for the SEM has no imageforming lens. It is not sure, however, that the equal resolution to the probe diameter can be obtained in the case of a thick specimen. To study the relation between the specimen thickness and the resolution of the trans-mitted electron image obtained by the SEM, the following experiment was carried out.


Sign in / Sign up

Export Citation Format

Share Document