Using the scanning electron microscope for failure analysis of high density magnetic media

Author(s):  
Evelyn R. Ackerman ◽  
Gary D. Burnett

Advancements in state of the art high density Head/Disk retrieval systems has increased the demand for sophisticated failure analysis methods. From 1968 to 1974 the emphasis was on the number of tracks per inch. (TPI) ranging from 100 to 400 as summarized in Table 1. This emphasis shifted with the increase in densities to include the number of bits per inch (BPI). A bit is formed by magnetizing the Fe203 particles of the media in one direction and allowing magnetic heads to recognize specific data patterns. From 1977 to 1986 the tracks per inch increased from 470 to 1400 corresponding to an increase from 6300 to 10,800 bits per inch respectively. Due to the reduction in the bit and track sizes, build and operating environments of systems have become critical factors in media reliability.Using the Ferrofluid pattern developing technique, the scanning electron microscope can be a valuable diagnostic tool in the examination of failure sites on disks.

Author(s):  
John R. Devaney

Occasionally in history, an event may occur which has a profound influence on a technology. Such an event occurred when the scanning electron microscope became commercially available to industry in the mid 60's. Semiconductors were being increasingly used in high-reliability space and military applications both because of their small volume but, also, because of their inherent reliability. However, they did fail, both early in life and sometimes in middle or old age. Why they failed and how to prevent failure or prolong “useful life” was a worry which resulted in a blossoming of sophisticated failure analysis laboratories across the country. By 1966, the ability to build small structure integrated circuits was forging well ahead of techniques available to dissect and analyze these same failures. The arrival of the scanning electron microscope gave these analysts a new insight into failure mechanisms.


Author(s):  
Erik Paul ◽  
Holger Herzog ◽  
Sören Jansen ◽  
Christian Hobert ◽  
Eckhard Langer

Abstract This paper presents an effective device-level failure analysis (FA) method which uses a high-resolution low-kV Scanning Electron Microscope (SEM) in combination with an integrated state-of-the-art nanomanipulator to locate and characterize single defects in failing CMOS devices. The presented case studies utilize several FA-techniques in combination with SEM-based nanoprobing for nanometer node technologies and demonstrate how these methods are used to investigate the root cause of IC device failures. The methodology represents a highly-efficient physical failure analysis flow for 28nm and larger technology nodes.


Author(s):  
Julien Goxe ◽  
Béatrice Vanhuffel ◽  
Marie Castignolles ◽  
Thomas Zirilli

Abstract Passive Voltage Contrast (PVC) in a Scanning Electron Microscope (SEM) or a Focused Ion Beam (FIB) is a key Failure Analysis (FA) technique to highlight a leaky gate. The introduction of Silicon On Insulator (SOI) substrate in our recent automotive analog mixed-signal technology highlighted a new challenge: the Bottom Oxide (BOX) layer, by isolating the Silicon Active Area from the bulk made PVC technique less effective in finding leaky MOSFET gates. A solution involving sample preparation performed with standard FA toolset is proposed to enhance PVC on SOI substrate.


2013 ◽  
Vol 804 ◽  
pp. 333-336
Author(s):  
Yun Jian Jiang ◽  
Xiang Feng Zheng ◽  
Rong Gang Xue ◽  
Guo Zhen Dong ◽  
Ji Feng Zhao ◽  
...  

Through methods, such as microscope analysis, chemical analysis, metallography examination and scanning electron microscope etc, the causes resulting in high temperature reheater tube cracking of station boiler have been analyzed. The result indicates the crack is reheat crack, and structure stress, higher hardness and excessive welding residual stress are the primary inducement of tube joint crack.


1992 ◽  
Vol 114 (2) ◽  
pp. 274-279 ◽  
Author(s):  
K. Tanaka ◽  
K. Nishimori ◽  
K. Maeda ◽  
J. Matsuda ◽  
M. Hotta

A scanning electron microscope (SEM) with two secondary electron detectors is applied for the surface topography measurement of magnetic media. The principle of gradient determination of the SEM is based on a relation that the difference in the square signals between the two detectors is linearly proportional to surface gradient. The great advantage of the instrument is the capability of relocation for profiling. It is extremely useful for the examination of wear process at a fixed position in a sequential manner during wear testing. This is demonstrated by two sample data of measurement on thin film rigid disks.


Author(s):  
James Vickers ◽  
Seema Somani ◽  
Blake Freeman ◽  
Pete Carleson ◽  
Lubomír Tùma ◽  
...  

Abstract We report on using the voltage-contrast mechanism of a scanning electron microscope to probe electrical waveforms on FinFET transistors that are located within active integrated circuits. The FinFET devices are accessed from the backside of the integrated circuit, enabling electrical activity on any transistor within a working device to be probed. We demonstrate gigahertz-bandwidth probing at 10-nm resolution using a stroboscopic pulsed electron source.


Sign in / Sign up

Export Citation Format

Share Document