scholarly journals Is Low Accelerating Voltage Always the Best for Semiconductor Inspection and Metrology?

2004 ◽  
Vol 12 (1) ◽  
pp. 46-47
Author(s):  
M. T. Postek ◽  
A. E. Vladár

Low accelerating voltage operation is an excellent mode of scanning electron microscopy and it is extensively used for measurements in semiconductor production. The beam penetration is small, and if properly applied, the specimen charging is kept at acceptable levels. But, is this always enough? Today, the scanning electron microscope (SEM) is being used in photomask metrology and imaging where charging is excessive. Charging is difficult to quantify and control as it varies greatly with instruments, operating conditions and sample. Therefore, it is also very difficult to model accurately. For accurate metrology charging must be overcome because the dynamic charging of the sample deflects the electron beam from its intended position and the intensity of the induced signal may vary uncontrollably. Deflection of the electron beam of even a few nanometers potentially results in a measurement error that is significant to modern semiconductor production.

Author(s):  
David Joy ◽  
James Pawley

The scanning electron microscope (SEM) builds up an image by sampling contiguous sub-volumes near the surface of the specimen. A fine electron beam selectively excites each sub-volume and then the intensity of some resulting signal is measured. The spatial resolution of images made using such a process is limited by at least three factors. Two of these determine the size of the interaction volume: the size of the electron probe and the extent to which detectable signal is excited from locations remote from the beam impact point. A third limitation emerges from the fact that the probing beam is composed of a finite number of discrete particles and therefore that the accuracy with which any detectable signal can be measured is limited by Poisson statistics applied to this number (or to the number of events actually detected if this is smaller).


Author(s):  
G.A.C. Jones ◽  
H. Ahmed ◽  
W.C. Nixon

A special type of post-lens single deflection coils have been developed for use in various applications of micro electron beam technology. The coil geometry has been chosen to give small values of the uncorrectable aberrations and to correct for field curvature by dynamic focusing. With this system 10,000 lines/field may be used in scanning electron microscopy leading to electrical raster shift only to search a specimen. The same type of system could be used to produce high resolution special purpose displays or for direct electron beam photographic recording.In Figure 1 the lettered grid is 3 mm in diameter and the scanned circle is 9 mm in diameter.


2006 ◽  
Vol 14 (4) ◽  
pp. 62-63
Author(s):  
Ronald Vane ◽  
Vince Carlino

Traditionally, contamination control in SEMs has focused on pump oils, finger prints, dirty specimens, and good vacuum practice in manufacturing. Now, the use of dry pumps at all stages of the vacuum system of new FE SEMs, and the use of better vacuum practices on the part on users and manufacturers have made environmental hydrocarbons, the hydrocarbon background contamination of our world, a significant source of the remaining hydrocarbons in electron microscope vacuum systems. These environment sources of hydrocarbons (HC) cause a loss of resolution and contrast in imaging at the highest levels of magnification.


Author(s):  
J. C. Russ ◽  
E. McNatt

In order to study the retention of copper in cirrhotic liver, rats were made cirrhotic by carbon tetrachloride inhalation twice weekly for three months and fed 0.2% copper acetate ad libidum in drinking water for one month. The liver tissue was fixed in osmium, sectioned approximately 2000 Å thick, and stained with lead citrate. The section was examined in a scanning electron microscope (JEOLCO JSM-2) in the transmission electron mode.Figure 1 shows a typical area that includes a red blood cell in a sinusoid, a disse, and a portion of the cytoplasm of a hepatocyte which contains several mitochondria, peribiliary dense bodies, glycogen granules, and endoplasmic reticulum.


Author(s):  
Mamaeva S.N. ◽  
Vinokurov R.R. ◽  
Munkhalova Ya.A. ◽  
Dyakonova D.P. ◽  
Platonova V.A. ◽  
...  

Currently, due to the intensive development of high-tech science-intensive medical and research devices, more and more attention is paid to the development of diagnostics of rare and difficult to diagnose diseases. It is known that among numerous nephropathies, hematuria may be the only symptom of kidney and urinary tract diseases, which complicates their diagnosis and treatment. In order to develop new approaches for the diagnosis of nephropathies, the authors have been studying the morphology of red blood cells in the blood and urine of children and adults using a scanning electron microscope for several years. The paper presents the results of studies of children with various kidney diseases, including IgA-nephropathy, and chronic glomerulonephritis. Scanning electron microscopy was used for the first time to detect nanoparticles on the surface of red blood cells, the size of which is comparable to the size of viruses, which became the basis for one of the authors ' assumptions, namely, the possible transport of certain types of viruses by red blood cells. Thus, some kidney diseases could be considered virus-associated. This paper presents for the first time the results of determining the glomerular filtration rate of both kidneys separately in the study of separate kidney function and of the study of urine smears obtained during catheterization of the ureters in patients with hydronephrosis of one of the kidneys by scanning electron microscopy. As in previous studies, nanoparticles were found on the surface of red blood cells, which leads to the conclusion about the possible viral nature of the disease of the considered patient. In addition, smear images obtained using a microscope showed a significant difference in the elements of the right and left kidneys urine, which did not contradict the data on the study of glomerular filtration rate. According to the authors, the capabilities of the scanning electron microscope can be applied in fundamental research of kidney diseases at the cellular and molecular levels, forming new ideas about their origin, as well as on the basis of which new methods of non-invasive diagnostics can be built.


2018 ◽  
Author(s):  
Lo Chea Wee ◽  
Tan Sze Yee ◽  
Gan Sue Yin ◽  
Goh Cin Sheng

Abstract Advanced package technology often includes multi-chips in one package to accommodate the technology demand on size & functionality. Die tilting leads to poor device performance for all kinds of multi-chip packages such as chip by chip (CbC), chip on chip (CoC), and the package with both CbC and CoC. Traditional die tilting measured by optical microscopy and scanning electron microscopy has capability issue due to wave or electron beam blocking at area of interest by electronic components nearby. In this paper, the feasibility of using profilemeter to investigate die tilting in single and multi-chips is demonstrated. Our results validate that the profilemeter is the most profound metrology for die tilting analysis especially on multi-chip packages, and can achieve an accuracy of <2μm comparable to SEM.


Author(s):  
J R Santos-Mallet ◽  
T D Balthazar ◽  
A A Oliveira ◽  
W A Marques ◽  
A Q Bastos ◽  
...  

Abstract The aim of the present study was to describe the morphology of the eggs of Culex (Culex) saltanensis Dyar that occurs in the Neotropical region. Eggs of the Cx. (Cux.) saltanensis were collected at the Mata Atlântica FIOCRUZ campus, fixed in 1% osmium tetroxide, prepared for mounting on metal supports, observed under a scanning electron microscope, and described morphologically. The eggs had a coniform shape with a length of approximately 0.5 mm (505–510 µm) and a width in the median portion of 117 µm (113–123 µm). Upper portion is lined with tubers of irregular shape and varying sizes (0.64–1.31 µm), located on a cross-linked matrix forming bands observed under optical microscopy. The micropyle is encased in a necklace of approximately 6.6-µm plates arranged in a flower-like shape. Comparing Cx. (Cux.) saltanensis eggs with several species of different genera, important divergent characteristics can be observed. However, this study points to the need for new descriptions of eggs of species belonging to the same subgenus in order to analyze if there will be differences between them. Culex (Cux.) saltanensis eggs have particular characteristics not observed in eggs of other Culicidae genera.


1972 ◽  
Vol 3 (3) ◽  
pp. 181-188 ◽  
Author(s):  
Christine Dahl

AbstractA method for preparation of alcohol-preserved culicid larvae for Scanning Electron Microscope (SEM) studies is described. It is based on dehydration by ethanol-xylol and fast evaporation of xylol in +8o° C. for ten minutes. For taxonomic studies such as examination of pecten teeth, comb scales and microtrichiae in magnifications up to 6oooX the method is suitable. For studies of receptor structures on hair-tufts and microstructures of the body integument alcohol preserved material is less satisfactory. The microstructure of the comb scales is figured and their function discussed. Differences in the ultrastructure of the abdominal hair-tufts are pointed out.


1988 ◽  
Vol 62 (2) ◽  
pp. 141-147 ◽  
Author(s):  
F. J. Kruger ◽  
V. L. Hamilton-Attwell

ABSTRACTSchistosoma haematobium miracidia were collected from a locality with a high prevalence of human infection with the animal parasite, S. mattheei, which hybridizes with S. haematobium, and from 2 localities with negligible infection rates. The terebratoria of the miracidia from these localities were compared with each other, with laboratory maintained S. haematobium and with four populations of S. mattheei by means of scanning electron microscopy. It was found that the terebratorial membrane of certain of the S. haematobium miracidia from the locality with a high S. mattheei prevalence in humans, resembled the more intricate membrane of S. mattheei. This suggests introgressive hybridization between S. haematobium and S. haematobium x S. mattheei.


Sign in / Sign up

Export Citation Format

Share Document