Implantable CPW-fed rectangular patch antenna for ISM band biomedical applications

2013 ◽  
Vol 6 (1) ◽  
pp. 101-107
Author(s):  
Srinivasan Ashok Kumar ◽  
Thangavelu Shanmuganantham

Implantable antennas have recently been receiving substantial attention for medical diagnosis and treatment. In this paper, a coplanar waveguide-fed monopole antenna for industrial, scientific, and medical (ISM) band biomedical applications is proposed. The antenna has a simple structure is placed on human tissues such as muscle, fat, and skin. The designed antenna is made compatible for implantation by embedding it in an FR4 substrate. The proposed antenna is simulated using the method of moment's software IE3D by assuming the predetermined dielectric constant for the human muscle tissue, fat, and skin. The antenna operates in the frequency of ISM bands, 2.4–2.48 GHz. Simulated and measured gains attain −7.7 and −8 dBi in the frequency of 2.45 GHz. The radiation pattern, return loss, current distribution, and gain of these antennas were examined and characterized.

2021 ◽  
Author(s):  
Majedeh Seydi ◽  
Mohammad Sajjad Bayati

Abstract A rectangular meandering-microstrip patch antenna (RM-MPA) with shorting pin for implant antenna and biomedical applications at industrial, scientific, and medical (ISM) band is proposed. The rectangular patch has length of l =14 mm and width of w =9.4 mm. The substrate and superstrate are made of Rogers 3210 with dielectric constant equals 10.2. The RMMPA is placed between the substrate and superstrate dielectric layers whose same thickness equals 0.635 mm. The proposed antenna is fed by a 50-ohm coaxial probe, at the centre of the length and edge of the width of the patch. The input impedance of patch antenna varies with the patch geometry. Thus, the geometry of the patch changed to achieve impedance matching at ISM band. The rectangular patch divided to three sections along width for meandering. The resonance frequency is tuned by meandering each section. The proposed antenna is simulated in free space and skin phantom. Proposed antenna has efficiency of 90%, bandwidth 1.02%. Both radiation pattern and SAR are evaluated which SAR level is below the safety and satisfies SAR standards. Finally, the antenna is tested in minced meat and tissue liquid.


2014 ◽  
Vol 24 (01) ◽  
pp. 1550014 ◽  
Author(s):  
S. Ashok Kumar ◽  
T. Shanmuganantham

A novel coplanar waveguide (CPW) fed circular slot antennas are proposed for industrial, scientific and medical (ISM) band (2.4–2.48 GHz) applications. To make the designed antenna suitable for implantation, it is embedded in biocompatible Al2O3 ceramic substrate. The antenna was simulated by immersing it in a phantom liquid, imitating the electrical properties of the human muscle tissue. A study of the sensitivity of the antenna performance as a function of the dielectric parameters of the environment in which it is immersed was performed. Simulations in various dimensions state demonstrate that the antenna covers the complete ISM band. The demonstration among the design EM characteristics of the antenna is presented by current distributions.


2013 ◽  
Vol 6 (2) ◽  
pp. 167-172 ◽  
Author(s):  
Srinivasan Ashok Kumar ◽  
Thangavelu Shanmuganantham

A novel coplanar waveguide fed Industrial, Scientific, and Medical (ISM) band implantable crossed-type triangular slot antenna is proposed for biomedical applications. The antenna operates at the center frequency of 2450 MHz, which is in ISM band, to support GHz wideband communication for high-data rate implantable biomedical application. The size of the antenna is 78 mm3 (10 mm × 12 mm × 0.65 mm). The simulated and measured bandwidths are 7.9 and 8.2% at the resonant frequency of 2.45 GHz. The specific absorption rate distribution induced by the implantable antenna inside a human body tissue model is evaluated. The communication between the implanted antenna and external device is also examined. The proposed antenna has substantial merits such as miniaturization, lower return loss, better impedance matching, and high gain over other implanted antennas.


2018 ◽  
Vol 7 (3) ◽  
pp. 56-63 ◽  
Author(s):  
A. Jaiswal ◽  
R. K. Sarin ◽  
B. Raj ◽  
S. Sukhija

In this paper, a novel circular slotted rectangular patch antenna with three triangle shape Defected Ground Structure (DGS) has been proposed. Radiating patch is made by cutting circular slots of radius 3 mm from the three sides and center of the conventional rectangular patch structure and three triangle shape defects are presented on the ground layer. The size of the proposed antenna is 38 X 25 mm2. Optimization is performed and simulation results have been obtained using Empire XCcel 5.51 software. Thus, a miniaturized antenna is designed which has three impedance bandwidths of 0.957 GHz,  0.779 GHz, 0.665 GHz with resonant frequencies at 3.33 GHz, 6.97 GHz and 8.59 GHz and the corresponding return loss at the three resonant frequencies are -40 dB, -43 dB and -38.71 dB respectively. A prototype is also fabricated and tested. Fine agreement between the measured and simulated results has been obtained. It has been observed that introducing three triangle shape defects on the ground plane results in increased bandwidth, less return loss, good radiation pattern and better impedance matching over the required operating bands which can be used for wireless applications and future 5G applications.


IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 43547-43554 ◽  
Author(s):  
Kumar Naik Ketavath ◽  
Dattatreya Gopi ◽  
Sriram Sandhya Rani

Author(s):  
Sanyog Rawat ◽  
Kamlesh Kumar Sharma

<p class="Abstract"><span style="font-weight: normal;">In this paper a new geometry of patch antenna is proposed with improved bandwidth and circular polarization. The radiation performance of circularly polarized rectangular patch antenna is investigated by applying IE3D simulation software and its performance is compared with that of conventional rectangular patch antenna.</span> <span style="font-weight: normal;">Finite Ground truncation technique is used to obtain the desired results. The simulated return loss, axial ratio and smith chart with frequency for the proposed antenna is reported in this paper. It is shown that by selecting suitable ground-plane dimensions, air gap and location of the slits, the impedance bandwidth can be enhanced upto 10.15 % as compared to conventional rectangular patch (4.24%) with an axial ratio bandwidth of 4.05%.</span></p><p> </p><p> </p>


In this paper, a metamaterial based compact multiband rectangular microstrip patch antenna is proposed. The return loss of metamaterial loaded microstrip patch antenna obtained at the resonant frequency 2.4GHz. The metamaterial structure printed on FR4 substrate at hight of 1.6mm from the ground plane. The FR4 substrate has 4.4 dielectric constant.These metamterial structures are periodic in nature and possesses negative permittivity and negative permeability. The greatest advantage of metamaterial loading will be miniaturization. This metamterial loaded rectangular patch antenna is simulated and tested using HFSS Simulator, where an electromagnetic analysis tool is used. The fabricated antennas results are measured using Vector Network Analyzer (VNA).


2019 ◽  
Vol 8 (1) ◽  
pp. 90-98
Author(s):  
Mohammed K. Al-Obaidi ◽  
Ezri Mohd ◽  
Noorsaliza Abdullah ◽  
Samsul Haimi Dahlan ◽  
Jawad Ali

This work presents the design and implementation of Rotman lens as a beam steering device for Industrial, Scientific, and Medical (ISM) applications. 2.45 GHz is considered as a center frequency design with (2-6) GHz frequency bandwidth. The beam steering is examined to cover ±21o scan angle with maximum main lobe magnitude 10.1 dBi, rectangular patch antennas are used as radiation elements to beam the output far field. The work is extended to compare between the tapered line which is used for matching between 50-Ω ports and lens cavity. CST microwave simulation studio results show that the rectangular taper line can yield 2 dB return loss less than linear taper line with a little bit shifting in responses for same input and load impedance.