Method of Measuring the Spectral Shape of the Radiation Line of a Three-Micron Long-Path Laser Gas Analyzer

2004 ◽  
Vol 71 (4) ◽  
pp. 580-587
Author(s):  
S. V. Ivanov ◽  
V. Ya. Panchenko
2016 ◽  
Vol E99.C (3) ◽  
pp. 381-384 ◽  
Author(s):  
Takuma YASUDA ◽  
Nobuhiko OZAKI ◽  
Hiroshi SHIBATA ◽  
Shunsuke OHKOUCHI ◽  
Naoki IKEDA ◽  
...  

2021 ◽  
pp. 875529302110279
Author(s):  
Sanaz Rezaeian ◽  
Linda Al Atik ◽  
Nicolas M Kuehn ◽  
Norman Abrahamson ◽  
Yousef Bozorgnia ◽  
...  

This article develops global models of damping scaling factors (DSFs) for subduction zone earthquakes that are functions of the damping ratio, spectral period, earthquake magnitude, and distance. The Next Generation Attenuation for subduction earthquakes (NGA-Sub) project has developed the largest uniformly processed database of recorded ground motions to date from seven subduction regions: Alaska, Cascadia, Central America and Mexico, South America, Japan, Taiwan, and New Zealand. NGA-Sub used this database to develop new ground motion models (GMMs) at a reference 5% damping ratio. We worked with the NGA-Sub project team to develop an extended database that includes pseudo-spectral accelerations (PSA) for 11 damping ratios between 0.5% and 30%. We use this database to develop parametric models of DSF for both interface and intraslab subduction earthquakes that can be used to adjust any subduction GMM from a reference 5% damping ratio to other damping ratios. The DSF is strongly influenced by the response spectral shape and the duration of motion; therefore, in addition to the damping ratio, the median DSF model uses spectral period, magnitude, and distance as surrogate predictor variables to capture the effects of the spectral shape and the duration of motion. We also develop parametric models for the standard deviation of DSF. The models presented in this article are for the RotD50 horizontal component of PSA and are compared with the models for shallow crustal earthquakes in active tectonic regions. Some noticeable differences arise from the considerably longer duration of interface records for very large magnitude events and the enriched high-frequency content of intraslab records, compared with shallow crustal earthquakes. Regional differences are discussed by comparing the proposed global models with the data from each subduction region along with recommendations on the applicability of the models.


Author(s):  
V. V. Vitkin ◽  
E. E. Popov ◽  
A. A. Kharitonov ◽  
I. N. Kaliteevsky ◽  
V. M. Polyakov
Keyword(s):  

Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3026
Author(s):  
Woo-Jae Kim ◽  
In-Young Bang ◽  
Ji-Hwan Kim ◽  
Yeon-Soo Park ◽  
Hee-Tae Kwon ◽  
...  

The use of NF3 is significantly increasing every year. However, NF3 is a greenhouse gas with a very high global warming potential. Therefore, the development of a material to replace NF3 is required. F3NO is considered a potential replacement to NF3. In this study, the characteristics and cleaning performance of the F3NO plasma to replace the greenhouse gas NF3 were examined. Etching of SiO2 thin films was performed, the DC offset of the plasma of both gases (i.e., NF3 and F3NO) was analyzed, and a residual gas analysis was performed. Based on the analysis results, the characteristics of the F3NO plasma were studied, and the SiO2 etch rates of the NF3 and F3NO plasmas were compared. The results show that the etch rates of the two gases have a difference of 95% on average, and therefore, the cleaning performance of the F3NO plasma was demonstrated, and the potential benefit of replacing NF3 with F3NO was confirmed.


1973 ◽  
Vol 19 (11) ◽  
pp. 1243-1247 ◽  
Author(s):  
P A Drinker ◽  
D C Noonan ◽  
N Ramanaiah ◽  
J R Tole

Abstract Two different blood-gas analyzers were tested to determine the effects on blood pH measurement of changing the reference bridge solution from saturated KCl to normal saline (0.16 mol of NaCl per liter). This change, which necessitated the preparation of modified buffers equimolal in NaCl with respect to blood, virtually eliminated salt depletion of the bridge solution and improved the stability of the liquid-junction potential between the bridge solution and the sample. The instruments we used were the Corning 165 pH Blood Gas Analyzer and the Radiometer E5021 pH Electrode with PHM72 Acid Base Analyzer. Comparison of results on clinical blood samples indicates that performance with the modified bufferbridge system is the same as that obtained with the conventional scheme. Analytical performances of the Corning and Radiometer instruments for PO2 and PCO2, as well as for pH, were comparable.


1995 ◽  
Vol 23 (Supplement) ◽  
pp. A37
Author(s):  
Bartholomew Tortella ◽  
Robert Lavery ◽  
James Doran ◽  
John Seigel

Sign in / Sign up

Export Citation Format

Share Document