scholarly journals Identification and analysis of odor-active compounds from Choerospondias axillaris (Roxb.) Burtt et Hill with different moisture content levels and lacquer treatments

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Qifan Wang ◽  
Jun Shen ◽  
Bin Zeng ◽  
Huiyu Wang

Abstract The problem of indoor odors can greatly affect a room’s occupants. To identify odorants and comprehensively evaluate emissions from wooden materials, emissions and odors from Choerospondias axillaris (Roxb.) Burtt et Hill with different moisture content percentages and lacquer treatments were investigated in this study. Thermal desorption–gas chromatography–mass spectroscopy/olfactometry was used to analyze the release characteristics. In total, 11 key odor-active compounds were identified as moisture content gradually decreased, concentrating between 15 and 33 min. Total volatile organic compounds, total very volatile organic compounds, and total odor intensity decreased as moisture content decreased. In addition, 35 odor-active compounds, including aromatics, alkenes, aldehydes, esters, and alcohols, were identified in the odor control list. Polyurethane (PU), ultraviolet (UV), and waterborne coatings had a good inhibitory effect on eight odor characteristics, but some scents arose after lacquer treatment. For equilibrium moisture content, the major characteristics of Choerospondias axillaris were fragrant (9.4) and mint-like (3.0) compared with the fragrant (8.2), fruity (7.8), and pleasant (5.8) characteristics of PU coating; the flowery (5.9), fragrant (5.0), glue-like (4.3), and pineapple-like (4.3) characteristics of UV coating; and the antiseptic solution (3.6), fragrant (2.9), cigarette-like (2.8), and fruity (2.5) characteristics of waterborne coating. Based on multicomponent evaluation, a Choerospondias axillaris board with waterborne coating was suggested for use indoors.

Atmosphere ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 286
Author(s):  
Dorina Camelia Ilieș ◽  
Florin Marcu ◽  
Tudor Caciora ◽  
Liliana Indrie ◽  
Alexandru Ilieș ◽  
...  

Poor air quality inside museums is one of the main causes influencing the state of conservation of exhibits. Even if they are mostly placed in a controlled environment because of their construction materials, the exhibits can be very vulnerable to the influence of the internal microclimate. As a consequence, museum exhibits must be protected from potential negative effects. In order to prevent and stop the process of damage of the exhibits, monitoring the main parameters of the microclimate (especially temperature, humidity, and brightness) and keeping them in strict values is extremely important. The present study refers to the investigations and analysis of air quality inside a museum, located in a heritage building, from Romania. The paper focuses on monitoring and analysing temperature of air and walls, relative humidity (RH), CO2, brightness and particulate matters (PM), formaldehyde (HCHO), and total volatile organic compounds (TVOC). The monitoring was carried out in the Summer–Autumn 2020 Campaign, in two different exhibition areas (first floor and basement) and the main warehouse where the exhibits are kept and restored. The analyses aimed both at highlighting the hazard induced by the poor air quality inside the museum that the exhibits face. The results show that this environment is potentially harmful to both exposed items and people. Therefore, the number of days in which the ideal conditions in terms of temperature and RH are met are quite few, the concentration of suspended particles, formaldehyde, and total volatile organic compounds often exceed the limit allowed by the international standards in force. The results represent the basis for the development and implementation of strategies for long-term conservation of exhibits and to ensure a clean environment for employees, restorers, and visitors.


Author(s):  
Jia ◽  
Cao ◽  
Valaulikar ◽  
Fu ◽  
Sorin

Volatile organic compounds (VOCs) are released to the indoor air of retail stores from numerous products and activities, but available literature lacks a systematic understanding of the variability of VOC concentrations. In this study, we measured concentrations of total VOCs (TVOC) in 32 retail stores using a high-sensitivity photoionization detector (PID). Indoor thermal comfort parameters, including temperature, relative humidity, and air velocity, were simultaneously measured using an anemometer. The store-level TVOC concentrations ranged from 30 to 869 ppb and exceeded the LEED guideline in 31 stores. TVOC levels were notably high in hardware stores (median = 536 ppb, p = 0.0002) and paints, household, and home accessories sections within stores (p < 0.05). TVOC levels were elevated in mornings and evenings, possibly due to low ventilation and cleaning activities at the beginning and end of business hours. The between-store, within-store, and temporal variations accounted for 85%, 0.5%, and 14% of the total variance, respectively. The variance structure suggested that in-store VOC concentrations were predominantly driven by their source location, and representative monitoring should first consider covering various store types. Current store VOC levels present health concerns, but further studies are needed to evaluate risks among customers.


2018 ◽  
Vol 21 (1) ◽  
pp. 41-49
Author(s):  
Takahiro ISHIZAKA ◽  
Ayato KAWASHIMA ◽  
Naoki HISHIDA ◽  
Noriaki HAMADA

Sign in / Sign up

Export Citation Format

Share Document