scholarly journals Direct RT-PCR amplification of SARS-CoV-2 from clinical samples using a concentrated viral lysis-amplification buffer prepared with IGEPAL-630

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Alejandro Castellanos-Gonzalez ◽  
Thomas R. Shelite ◽  
Nicole Lloyd ◽  
Aygul Sadiqova ◽  
Ren Ping ◽  
...  

AbstractThe pandemic of 2019 caused by the novel coronavirus (SARS-CoV-2) is still rapidly spreading worldwide. Nucleic acid amplification serves as the gold standard method for confirmation of COVID-19 infection. However, challenges faced for diagnostic laboratories from undeveloped countries includes shortage of kits and supplies to purify viral RNA. Therefore, it is urgent to validate alternative nucleic acid isolation methods for SARS-CoV-2. Our results demonstrate that a concentrated viral lysis amplification buffer (vLAB) prepared with the nonionic detergent IGEPAL enables qualitative detection of SARS-CoV-2 by direct Reverse Transcriptase-Polymerase Chain Reaction (dRT-PCR). Furthermore, vLAB was effective in inactivating SARS-CoV-2. Since this method is inexpensive and no RNA purification equipment or additional cDNA synthesis is required, this dRT-PCR with vLAB should be considered as an alternative method for qualitative detection of SARS-CoV-2.

2020 ◽  
Author(s):  
Alejandro Castellanos-Gonzalez ◽  
Thomas Shelite ◽  
Lloyd Nicole ◽  
Sadiqova Aygul ◽  
Ping Ren ◽  
...  

Abstract The pandemic of 2019 caused by the novel coronavirus (SARS-CoV-2) is still rapidly spreading worldwide. Nucleic acid amplification serves as the gold standard method for confirmation of COVID-19 infection. However, challenges faced for diagnostic laboratories from undeveloped countries includes shortage of kits and supplies to purify viral RNA. Therefore, it is urgent to validate alternative nucleic acid isolation methods for SARS-CoV-2. Our results demonstrate that a concentrated viral lysis amplification buffer (vLAB) prepared with the nonionic detergent IGEPAL enables qualitative detection of SARS-CoV-2 by direct Reverse Transcriptase-Polymerase Chain Reaction (dRT-PCR). Furthermore, vLAB was effective in inactivating SARS-CoV-2. Since this method is inexpensive and no RNA purification equipment or additional cDNA synthesis is required, this dRT-PCR with vLAB should be considered as an alternative method for COVID-19 detection.


PLoS ONE ◽  
2021 ◽  
Vol 16 (6) ◽  
pp. e0252757
Author(s):  
Miyuki Mizoguchi ◽  
Sohei Harada ◽  
Koh Okamoto ◽  
Yoshimi Higurashi ◽  
Mahoko Ikeda ◽  
...  

Background A number of nucleic acid amplification tests (NAATs) for SARS-CoV-2 with different reagents have been approved for clinical use in Japan. These include research kits approved under emergency use authorization through simplified process to stabilize the supply of the reagents. Although these research kits have been increasingly used in clinical practice, limited data is available for the diagnostic performance in clinical settings. Methods We compared sensitivity, specificity, and cycle threshold (Ct) values obtained by NAATs using 10 kits approved in Japan including eight kits those receiving emergency use authorization using 69 frozen-stored clinical samples including 23 positive samples with various Ct values and 46 negative samples. Results Viral copy number of the frozen-stored samples determined with LightMix E-gene test ranged from 0.6 to 84521.1 copies/μL. While no false-positive results were obtained by any of these tests (specificity: 100% [95% CI, 88.9%-100%]), sensitivity of the nine tests ranged from 68.2% [95% CI, 45.1%-86.1%] to 95.5% [95% CI, 77.2%-99.9%] using LightMix E-gene test as the gold standard. All tests showed positive results for all samples with ≥100 copies/μL. Significant difference of Ct values even among tests amplifying the same genetic region (N1-CDC, N2) was also observed. Conclusion Difference in the diagnostic performance was observed among NAATs approved in Japan. Regarding diagnostic kits for emerging infectious diseases, a system is needed to ensure both rapidity of reagent supply and accuracy of diagnosis. Ct values, which are sometimes regarded as a marker of infectivity, are not interchangeable when obtained by different assays.


Author(s):  
G. G. Li ◽  
Z. Lv ◽  
Y. S. Wang ◽  
J. F. Li ◽  
L. F. Feng ◽  
...  

The 2019 novel coronavirus (2019-nCov) has caused increasing number of infected cases globally. This study was performed to analyze information regarding the transmission route and presence of viral nucleic acids on several clinical samples. Confirmed 2019-nCov-infected cases were identified in Dongyang and were treated according to guidelines for the diagnosis of 2019-nCov infection released by the National Health Commission. Information regarding the contacts that the infected people had was collected to determine whether it caused clustered cases. A series of successive nucleic acid examination of feces, oropharyngeal swabs, and sputum was also performed, and the results were analyzed. A total of 19 confirmed cases of 2019-nCov infection were identified in Dongyang, Zhejiang Province, China. Five cases showed severe symptoms, and the remaining ones showed mild manifestations. Ten cases infected from two asymptomatic individuals were clustered into two groups. Among 14 cases with consecutive nucleic acid test results, four patients showed positive results in feces after their negative conversion in oropharyngeal swabs. Asymptomatic individuals with the virus could cause 2019-nCov clustered cases, and the clustered cases may differ from sporadic cases on age and length of hospitalization. In addition, nucleic acids in feces last longer than those in oropharyngeal swabs.


2021 ◽  
Author(s):  
Shuang Wu ◽  
Xiaolu Shi ◽  
Qiongcheng Chen ◽  
Yixiang Jiang ◽  
Le Zuo ◽  
...  

Abstract Background: SARS-CoV-2 is a newly emerged coronavirus, causing the coronavirus disease 2019 (COVID-19) outbreak in December, 2019. As drugs and vaccines of COVID-19 remain in development, accurate virus detection plays a crucial role in the current public health crisis. Quantitative real-time reverse transcriptase-polymerase chain reaction (RT-qPCR) kits have been reliably used for detection of SARS-CoV-2 RNA since the beginning of the COVID-19 outbreak, whereas isothermal nucleic acid amplification-based point-of-care automated kits have also been considered as a simpler and rapid alternative. However, as these kits have only been developed and applied clinically within a short timeframe, their clinical performance has not been adequately evaluated to date. We describe a comparative study between a newly developed cross-priming isothermal amplification (CPA) kit (Kit A) and five RT-qPCR kits (Kits B–F) to evaluate their sensitivity, specificity, predictive values and accuracy. Methods: Fifty-two clinical samples were used including throat swabs (n=30), nasal swabs (n=7), nasopharyngeal swabs (n=7) and sputum specimens (n=8), comprising confirmed (n=26) and negative cases (n=26). SARS-CoV-2 detection was simultaneously performed on each sample using six nucleic acid amplification kits. The sensitivity, specificity, positive/negative predictive values (PPV/NPV) and the accuracy for each kit were assessed using clinical manifestation and molecular diagnoses as the reference standard. Reproducibility for RT-qPCR kits was evaluated in triplicate by three different operators using a SARS-CoV-2 RNA-positive sample. On the basis of the six kits’ evaluation results, CPA kit (Kit A) and two RT-qPCR Kits (Kit B and F) were applied to the SARS-CoV-2 detection in close-contacts of COVID-19 patients. Results: For Kit A, the sensitivity, specificity, PPV/NPV and accuracy were 100%. Among the five RT-qPCR kits, Kits B, C and F had good agreement with the clinical diagnostic reports (Kappa≥0.75); Kits D and E were less congruent (0.4≤Kappa<0.75). Differences between all kits were statistically significant (P<0.001). The reproducibility of RT-qPCR kits was determined using a coefficients of variation (CV) between 0.95% and 2.57%, indicating good reproducibility. Conclusions: This is the first comparative study to evaluate CPA and RT-qPCR kits’ specificity and sensitivity for SARS-CoV-2 detection, and could serve as a reference for clinical laboratories, thus informing testing protocols amid the rapidly progressing COVID-19 pandemic. Keywords: SARS-CoV-2; COVID-19; nucleic acid detection; real-time reverse transcriptase PCR (RT-qPCR); cross-priming isothermal amplification (CPA)


Author(s):  
Soon Keong Wee ◽  
Suppiah Paramalingam Sivalingam ◽  
Eric Peng Huat Yap

There is an ongoing worldwide coronavirus disease 2019 (Covid-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). At present, confirmatory diagnosis is by reverse transcription polymerase chain reaction (RT-PCR), typically taking several hours and requiring a molecular laboratory to perform. There is an urgent need for rapid, simplified and cost-effective detection methods. We have developed and analytically validated a protocol for direct rapid extraction-free PCR (DIRECT-PCR) detection of SARS-CoV-2 without the need for nucleic acid purification. As few as 6 RNA copies per reaction of viral nucleocapsid (N) gene from respiratory samples such as sputum and nasal exudate can be detected directly using our one-step inhibitor-resistant assay. The performance of this assay was validated on a commercially available portable PCR thermocycler. Viral lysis, reverse transcription, amplification and detection are achieved in a single-tube homogeneous reaction within 36 minutes. This minimized hands-on time, reduces turnaround-time for sample-to-result and obviates the need for RNA purification reagents. It could enable wider use of Covid-19 testing for diagnosis, screening and research in countries and regions where laboratory capabilities are limiting.


2020 ◽  
Author(s):  
Diem Hong Tran ◽  
Hoang Quoc Cuong ◽  
Hau Thi Tran ◽  
Uyen Phuong Le ◽  
Hoang Dang Khoa Do ◽  
...  

ABSTRACTThe COVID-19, caused by the novel coronavirus SARS-CoV-2, has broken out of control all over the globe and put the majority of the world under lockdown. There have been no specific antiviral medications for SARS-CoV-2 while vaccines are still under development. Thus, rapid diagnosis and necessary public health measures are currently key parts to contain the pandemic. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) is the gold standard method for SARS-CoV-2 detection. However, this method is not suitable for point-of-care (POC) diagnosis because of the timeconsuming procedure, the requirements of biosafety conditions and expensive equipment. In this study, the colorimetric isothermal nucleic acid amplification tests (iNAATs) for SARS-CoV-2 based on loop-mediated isothermal amplification (LAMP), cross-priming amplification (CPA), and polymerase spiral reaction (PSR) were developed and compared. The three methods exhibited similar performance with the limit of detection (LOD) as low as just 1 copy per reaction when evaluated on the synthetic DNA fragments. The results can be read with naked eyes within 30 minutes without crossreactivity to closely related coronaviruses. When tested with SARS-CoV-2 extracted genomic-RNA, LAMP outperformed both CPA and PSR assays. Moreover, the direct detection of SARS-CoV-2 in simulated patient samples (oropharyngeal and nasopharyngeal swabs) by colorimetric iNAATs was also successful. Further preparation of the lyophilized reagents for LAMP reactions revealed that the freeze-dried, ready-to-use kit maintained the sensitivity and LOD value of the liquid assays. These results strongly indicate that the colorimetric lyophilized LAMP test kit developed herein is highly suitable for detecting SARS-CoV-2 at POC.


2004 ◽  
Vol 70 (5) ◽  
pp. 3047-3054 ◽  
Author(s):  
Gary J. Vora ◽  
Carolyn E. Meador ◽  
David A. Stenger ◽  
Joanne D. Andreadis

ABSTRACT DNA microarray-based screening and diagnostic technologies have long promised comprehensive testing capabilities. However, the potential of these powerful tools has been limited by front-end target-specific nucleic acid amplification. Despite the sensitivity and specificity associated with PCR amplification, the inherent bias and limited throughput of this approach constrain the principal benefits of downstream microarray-based applications, especially for pathogen detection. To begin addressing alternative approaches, we investigated four front-end amplification strategies: random primed, isothermal Klenow fragment-based, φ29 DNA polymerase-based, and multiplex PCR. The utility of each amplification strategy was assessed by hybridizing amplicons to microarrays consisting of 70-mer oligonucleotide probes specific for enterohemorrhagic Escherichia coli O157:H7 and by quantitating their sensitivities for the detection of O157:H7 in laboratory and environmental samples. Although nearly identical levels of hybridization specificity were achieved for each method, multiplex PCR was at least 3 orders of magnitude more sensitive than any individual random amplification approach. However, the use of Klenow-plus-Klenow and φ29 polymerase-plus-Klenow tandem random amplification strategies provided better sensitivities than multiplex PCR. In addition, amplification biases among the five genetic loci tested were 2- to 20-fold for the random approaches, in contrast to >4 orders of magnitude for multiplex PCR. The same random amplification strategies were also able to detect all five diagnostic targets in a spiked environmental water sample that contained a 63-fold excess of contaminating DNA. The results presented here underscore the feasibility of using random amplification approaches and begin to systematically address the versatility of these approaches for unbiased pathogen detection from environmental sources.


2008 ◽  
Vol 22 (5-6) ◽  
pp. 287-293 ◽  
Author(s):  
Wasun Chantratita ◽  
Chonlaphat Sukasem ◽  
Supaporn Kaewpongsri ◽  
Chutatip Srichunrusami ◽  
Wantanit Pairoj ◽  
...  