scholarly journals Atmospheric diffuse plasma jet formation from positive-pseudo-streamer and negative pulseless glow discharges

2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Jing Li ◽  
Bingying Lei ◽  
Jing Wang ◽  
Boping Xu ◽  
Shuang Ran ◽  
...  

AbstractAtmospheric gas discharge is very likely to constrict into filaments and diffuse plasma formation is inefficient in most cases. Developing cost-efficient atmospheric diffuse plasma devices represents a significant challenge for high performance in biomedical decontamination and material processing. Here, we propose an alternative roadmap to produce a diffuse argon plasma jet by expanding and quenching the existing filamentary discharge at the initial or middle stage of streamer development. Possible mechanisms are summarized. With the gas flow velocity comparable to the ion drift one, enhancing ambipolar diffusion near the edge of the positive-streamer channel promotes the radial diffusion of newly-produced electrons, realizing the radial expansion of channel. Weakening electric field in front of the streamer head through head expansion and field offset, prevents the further development of streamer, leading to a positive-pseudo-streamer discharge. Reducing electric field in front of the negative-streamer head through ion compensation, impedes the initial growth of streamer, resulting in a negative pulseless glow discharge. The positive-pseudo-streamer and negative pulseless glow discharges function together to form the diffuse plasma jet.

2018 ◽  
Vol 15 (35) ◽  
pp. 117-124
Author(s):  
Kadhim A. Aadim

In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.


Author(s):  
Yuan yuan Jiang ◽  
Yanhui Wang ◽  
Yamin Hu ◽  
Jiao Zhang ◽  
Dezhen Wang

Abstract In this paper, a two-dimensional fluid model is used to study the properties of atmospheric-pressure argon plasma jet propagating into ambient nitrogen driven by a pulsed voltage, emphasizing the influence of gas velocity on the dynamic characteristics of the jet. The simulation results show that the argon jet exhibits a cylindrical shape channel and with the increase of propagation length, the jet channel gradually shrinks. The jet propagation velocity varies with time. Inside the dielectric tube, the plasma jet accelerates propagation and reaches its maximum value near the nozzle. Exiting from the tube, the propagation velocity of the plasma jet quickly decreases and when approaching the metal plane, the decrease of jet velocity slows down. The increase of gas speed leads to the variation of the jet spatial distribution. The electron density presents a solid structure at lower gas flow speeds, whereas an annular structure can be observed under the higher gas flow velocity in the ionization head. The jet length increases with the gas flow velocity. However, when the flow velocity exceeds a critical value, the increased rate of the plasma jet length becomes slow. Additionally, the influence of the gas flow speed on the production and transport of the reactive species is also studied and discussed.


2021 ◽  
Author(s):  
P. Y. Tan ◽  
O. H. Chin ◽  
R. Anpalagan ◽  
Y. T. Lau ◽  
H. C. Lee

CrystEngComm ◽  
2021 ◽  
Author(s):  
Yuzhu Pan ◽  
Xin Wang ◽  
Jingda Zhao ◽  
Yubing Xu ◽  
Yuwei Li ◽  
...  

Perovskites single crystals (PSCs) could be used to made high performance photoelectric detectors due to its superior optoelectronic characteristics. Generally, external electric field need to be applied in the PSCs-based...


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Munusamy Kuppan ◽  
Daichi Yamamoto ◽  
Genta Egawa ◽  
Sivaperuman Kalainathan ◽  
Satoru Yoshimura

Abstract(Bi1−xLax)(Fe,Co)O3 multiferroic magnetic film were fabricated using pulsed DC (direct current) sputtering technique and demonstrated magnetization reversal by applied electric field. The fabricated (Bi0.41La0.59)(Fe0.75Co0.25)O3 films exhibited hysteresis curves of both ferromagnetic and ferroelectric behavior. The saturated magnetization (Ms) of the multiferroic film was about 70 emu/cm3. The squareness (S) (= remanent magnetization (Mr)/Ms) and coercivity (Hc) of perpendicular to film plane are 0.64 and 4.2 kOe which are larger compared with films in parallel to film plane of 0.5 and 2.5 kOe. The electric and magnetic domain structures of the (Bi0.41La0.59)(Fe0.75Co0.25)O3 film analyzed by electric force microscopy (EFM) and magnetic force microscopy (MFM) were clearly induced with submicron scale by applying a local electric field. This magnetization reversal indicates the future realization of high performance magnetic device with low power consumption.


Molecules ◽  
2021 ◽  
Vol 26 (2) ◽  
pp. 437
Author(s):  
Marta Tikhomirov ◽  
Błażej Poźniak ◽  
Tomasz Śniegocki

The precise and reliable determination of buprenorphine concentration is fundamental in certain medical or research applications, particularly in pharmacokinetic studies of this opioid. The main challenge is, however, the development of an analytical method that is sensitive enough, as the detected in vivo concentrations often fall in very low ranges. Thus, in this study we aimed at developing a sensitive, repeatable, cost-efficient, and easy HPLC analytical protocol for buprenorphine in rabbit plasma. In order to obtain this, the HPLC-MS2 system was used to elaborate and validate the method for samples purified with liquid-liquid extraction. Fragment ions 468.6→396.2 and 468.6→414.2 were monitored, and the method resulted in a high repeatability and reproducibility and a limit of quantification of 0.25 µg/L with a recovery of 98.7–109.0%. The method was linear in a range of 0.25–2000 µg/L. The suitability of the analytical procedure was tested in rabbits in a pilot pharmacokinetic study, and it was revealed that the method was suitable for comprehensively describing the pharmacokinetic profile after buprenorphine intravenous administration at a dose of 300 µg/kg. Thus, the method suitability for pharmacokinetic application was confirmed by both the good validation results of the method and successful in vivo tests in rabbits.


Respiration ◽  
2021 ◽  
pp. 1-5
Author(s):  
Erik E. Folch ◽  
Catherine L. Oberg ◽  
Atul C. Mehta ◽  
Adnan Majid ◽  
Colleen Keyes ◽  
...  

<b><i>Background:</i></b> Argon plasma coagulation (APC) is a tool used in the management of tracheobronchial obstruction or bleeding. Complications include gas embolism which can cause devastating effects including hemodynamic instability, cardiac arrest, and stroke. Multiple theories as to how gas embolism occurs with APC have been postulated; however, none have identified the exact mechanism. <b><i>Objectives:</i></b> To identify the mechanism by which APC causes gas embolism in the tracheobronchial tree. <b><i>Methods:</i></b> Using an explanted porcine tracheobronchial tree with lung parenchyma, the APC catheter was applied through noncontact and direct contact to the endobronchial airway mucosa via flexible bronchoscopy. This was done at multiple gas flow settings and pulse durations. Visual changes in the mucosa were photographed, videoed, and described. <b><i>Results:</i></b> Gross evidence of submucosal gas transfer occurred when the APC catheter was in direct contact with the mucosa at all gas flow settings in all applications, despite using shorter pulse durations. Whenever the catheter was not in contact with the mucosa, there was no transfer of gas at any gas flow setting or pulse duration. <b><i>Conclusions:</i></b> Direct mucosal contact with the APC probe leads to submucosal gas deposition and is a likely mechanism for gas entry into the intravascular space. In reported cases of APC-associated gas embolism, presence of a vascularized endobronchial tumor may have increased the risk of gas tracking into the intravascular space. Care should be taken when applying APC during brisk bleeding or limited vision, as inadvertent mucosal contact may occur and could increase the risk of gas embolism.


Sign in / Sign up

Export Citation Format

Share Document