Sensitive and highly selective determination of vitamin B1 in the presence of other vitamin B complexes using functionalized gold nanoparticles as fluorophore

RSC Advances ◽  
2015 ◽  
Vol 5 (62) ◽  
pp. 49920-49925 ◽  
Author(s):  
Sekar Shankar ◽  
S. Abraham John

This work describes the spectrofluorimetric determination of thiamine in the presence of vitamin B complexes using 4-amino-6-hydroxy-2-mercaptopyrimidine as fluorophore. The detection limit was found to be 6.8 fM L−1 (S/N = 3).

2014 ◽  
Vol 17 (1) ◽  
pp. 001-004 ◽  
Author(s):  
Benzhi Liu ◽  
Min Wang

Application of gold nanoparticles self-assembled with N-carboxyl- L-cysteine for the determination of iron(III) was investigated. Differential pulse adsorptive stripping voltammetry was used to detect iron(III). Various operational parameters were investigated and discussed in terms of their effects on the measurement signals. A linear range from 0.1 nM to 1.8 nM with a detection limit of 0.03 nMwas obtained under optimized conditions. The applicability of the method was successfully tested by determination of iron(III) in sea water samples.


RSC Advances ◽  
2020 ◽  
Vol 10 (52) ◽  
pp. 31400-31410 ◽  
Author(s):  
Sushama Sahu ◽  
Reshma ◽  
Srishti Sharma ◽  
Indrapal Karbhal ◽  
Kallol K. Ghosh

The excellent biocompatible and monodispersed gold nanoparticles (AuNPs) functionalized by amino based ionic liquid (IL) have been synthesized for the demonstration of their interaction with human serum albumin (HSA).


1989 ◽  
Vol 54 (10) ◽  
pp. 2667-2673 ◽  
Author(s):  
Vojtěch Steiner ◽  
Pavel Engst ◽  
Zdeněk Zelinger ◽  
Milan Horák

The optoacoustic analyzer with a tunable CO2 laser source employed in the present work permits a selective determination of ethylene in trace concentrations higher than 5 ppb (=detection limit for the 10P(14) emission line of the CO2 laser, ν = 949.5 cm-1) and of vinylchloride higher than 42 ppb (= detection limit for the 10P(22) CO2 laser line, ν= 942.4 cm-1). this method covers for both compounds the concentration range corresponding to the hygienic standard. It can be also used for the determination of styrene vapour with concentrations higher than 1.5 ppm.


2010 ◽  
Vol 157 (9) ◽  
pp. F116 ◽  
Author(s):  
Nada F. Atta ◽  
Ahmed Galal ◽  
Fekria M. Abu-Attia ◽  
Shereen M. Azab

2019 ◽  
Vol 3 (4) ◽  
pp. 306-312
Author(s):  
Mi Zhou ◽  
Long Han ◽  
Haibo He ◽  
Dongmei Deng ◽  
Lin Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document