A fluorescent porous covalent-organic polymer (COP-3) for highly selective and sensitive detection of Fe3+ in aqueous solution

2021 ◽  
Author(s):  
Han Zhang ◽  
Guanyu Ding ◽  
Dongxu Cui ◽  
Afifa Yousuf ◽  
Li Chen ◽  
...  

A TPE-based fluorescent porous covalent organic polymer (COP-3) was designed and synthesized. The COP-3 exhibits the excellent performance in sensing Fe3+ with highly anti-interference, recyclicity and low limit of detection...

2019 ◽  
Vol 55 (82) ◽  
pp. 12328-12331 ◽  
Author(s):  
Han Zhang ◽  
Jie Zhou ◽  
Guo-Gang Shan ◽  
Guang-Fu Li ◽  
Chun-Yi Sun ◽  
...  

A new COP is synthesized, exhibiting excellent performance as an Fe3+ sensor with a LOD of 23.5 ppb, and solid-state illumination.


Chemosensors ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 65
Author(s):  
Minji Lee ◽  
Donghwan Choe ◽  
Soyoung Park ◽  
Hyeongjin Kim ◽  
Soomin Jeong ◽  
...  

A novel thiosemicarbazide-based fluorescent sensor (AFC) was developed. It was successfully applied to detect hypochlorite (ClO−) with fluorescence quenching in bis-tris buffer. The limit of detection of AFC for ClO− was analyzed to be 58.7 μM. Importantly, AFC could be employed as an efficient and practical fluorescent sensor for ClO− in water sample and zebrafish. Moreover, AFC showed a marked selectivity to ClO− over varied competitive analytes with reactive oxygen species. The detection process of AFC to ClO− was illustrated by UV–visible and fluorescent spectroscopy and electrospray ionization–mass spectrometry (ESI–MS).


RSC Advances ◽  
2021 ◽  
Vol 11 (39) ◽  
pp. 23975-23984
Author(s):  
Xue Yang ◽  
Yixia Ren ◽  
Hongmei Chai ◽  
Xiufang Hou ◽  
Zhixiang Wang ◽  
...  

Four fluorescent 2D Zn-MOFs based on a flexible triangular ligand and linear N-donor ligands are hydrothermally prepared and used to detect nitrobenzene in aqueous solution with high sensitivity, demonstrating their potential as fluorescent sensors.


2021 ◽  
Vol 11 (11) ◽  
pp. 1774-1780
Author(s):  
Shanji Fan ◽  
Hong Huang ◽  
Hong Chen ◽  
Jiachi Xu ◽  
Zecheng Hu ◽  
...  

A CdS nanocrystal enhanced TiO2 nanotubes (CdS@TiO2 NATs) photoelectrode was prepared via successive ionic layer adsorption and reaction (SILAR) of CdS on the surface of TiO2 NATs. A HS-aptamer owing a specific binding toward cytochrome c was modified onto the CdS@TiO2 NATs, which resulting a decrease in the photoelectrical current intensity. Cytochrome c is therefore quantified based on the decrease in photoelectrical current. High specificity and high sensitivity were obtained with a linear range from 3 pM to 80 nM, and a limit of detection of 2.53 pM.


2017 ◽  
Vol 56 (36) ◽  
pp. 10174-10182 ◽  
Author(s):  
Seenu Ravi ◽  
Pillaiyar Puthiaraj ◽  
Kyung Ho Row ◽  
Dong-Wha Park ◽  
Wha-Seung Ahn

2017 ◽  
Vol 14 (6) ◽  
pp. 385
Author(s):  
Yu Tian ◽  
Jianbo Li ◽  
Yanhui Wang ◽  
Chaofan Ding ◽  
Yuanling Sun ◽  
...  

Environmental contextBisphenol A, an important industrial material widely used as a plasticiser, fire retardant and resin polymer material, can cause endocrine disorders and precocious puberty. We developed a portable and efficient method for determining bisphenol A, and apply it to the detection of bisphenol A in bottles for infants and young children. AbstractA highly effective electrochemical sensor was developed for the highly sensitive detection of bisphenol A (BPA). The sensor is based on a glassy carbon electrode modified with a composite comprising 1-butyl-3-methyl imidazole hydrobromide (an ionic liquid, IL)-functionalised grapheme oxide (GO) to which gold nanoparticles (AuNPs) and carboxylic acid-functionalised carbon nanotubes (CNT) were absorbed. The negatively charged carboxylic acid-functionalised CNTs and AuNPs are adsorbed on the positively charged GO-IL composite film by electrostatic adsorption. The as-prepared GO-IL-CNT-AuNP hybrid nanocomposites exhibit excellent water solubility owing to the high hydrophilicity of the GO-IL components. Moreover, the excellent conductivity is attributed to the good conductivity of the IL, CNT and AuNP components. The hydrid materials enhance the preconcentration efficiency of BPA and accelerate the electron transfer rate at the electrode–electrolyte interface, as such the resultant fabricated electrochemical sensor displays a fast, stable and sensitive detection performance for trace amounts of BPA. Differential pulse voltammetry was used as a sensitive analytical method for the determination of BPA, and a much wider linear dynamic range of BPA determination was found between 5 and 100nM. The limit of detection for BPA was found down to 1.5nM based on a signal to nose ratio of 3. The modified electrode was successfully employed to detect BPA extracted from a plastic water bottle and milk carton.


RSC Advances ◽  
2015 ◽  
Vol 5 (36) ◽  
pp. 28394-28400 ◽  
Author(s):  
Yunpan Ying ◽  
Yuanlong Xiao ◽  
Jing Ma ◽  
Xiangyu Guo ◽  
Hongliang Huang ◽  
...  

Mixed matrix membrane containing ZIF-7 exhibits the excellent performance in the recovery of acetone from fermentation broths.


Sign in / Sign up

Export Citation Format

Share Document