Binding of toluidine blue-myristic acid derivative to cucurbit[7]uril and human serum albumin: computational and biophysical insights towards a biosupramolecular assembly

Author(s):  
Felipe Andrade-Villalobos ◽  
Daniel Zúñiga-Núñez ◽  
Angelica Fierro ◽  
Denis Fuentealba

A new toluidine blue-myristic acid photosensitizer derivate (TBOMyr) was investigated as a design molecule to bind simultaneously to cucurbit[7]uril (CB[7]) and human serum albumin (HSA) with the aim of constructing...

2007 ◽  
Vol 330-332 ◽  
pp. 1339-1342 ◽  
Author(s):  
Tetsushi Taguchi ◽  
H. Saito ◽  
Masashi Iwasashi ◽  
Masataka Sakane ◽  
S. Kakinoki ◽  
...  

A biocompatible glue consisting of human serum albumin (HSA) and citric acid derivative (CAD), named CAD-A glue was developed. CAD was successfully synthesized by the reaction between citric acid and N-hydroxysuccinimide in the presence of 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide hydrochloride. When the CAD-A glue was applied to the collagenbased casings, it took 7 min to obtain half of maximum bonding strength (760 g/cm2). The bonding strength of this glue to collagen-based casings increased with increasing of HSA concentration.The bonding strength of CAD-A glue increased with increasing CAD concentration up to 200 mM, and then decreased with increasing CAD concentration under the fixed HSA concentration (50 w/w%). The CAD-A glue showed excellent wound closure ability rather than fibrin glue when applied to the mouse skin. These results suggested that this developed glue had both tissue compatibility and bonding strength for use in clinical field.


2009 ◽  
Vol 90A (2) ◽  
pp. 543-548 ◽  
Author(s):  
Masashi Iwasashi ◽  
Masataka Sakane ◽  
Hirofumi Saito ◽  
Tetsushi Taguchi ◽  
Tetsuya Tateishi ◽  
...  

2008 ◽  
Vol 2 (1) ◽  
pp. 143-147 ◽  
Author(s):  
Sachiro Kakinoki ◽  
Yasuyuki Katada ◽  
Yoshiyuki Uchida ◽  
Tetsushi Taguchi

The surface of stainless steel (SUS316L) was modified by alternating immersion in a solution of human serum albumin (HSA) and solution of a tartaric acid derivative (TAD). The resulting HSA/TAD-immobilized SUS316L was characterized by means of contact-angle measurement, attenuated total-reflectance Fourier-transform infrared spectroscopy, atomic force microscopy, and X-ray photoelectron spectroscopy. A HSA/TAD layer was formed on the surface of SUS316L, the thickness of which increased with increasing numbers of cycles of alternating immersion in the two solutions. The HSA/TAD layer on SUS316L was stable to washing in 1 M NaCl or 5 vol% sodium dodecyl sulfate, showing that the layer was immobilized by covalent bonding rather than electrostatic or hydrophobic interaction. The presence of the HSA/TAD layer on the SUS316L suppressed the formation of a fibrin network. Alternating immersion in solutions of HSA and TAD is a useful technique for functionalizing the surfaces of metals.


1969 ◽  
Vol 08 (01) ◽  
pp. 15-21 ◽  
Author(s):  
K. E. Scheer ◽  
J. Heep ◽  
W. Maier-Borst ◽  
W. J. Lorenz ◽  
H. Sinn ◽  
...  

ZusammenfassungNach tierexperimentellen Voruntersuchungen wurde die Placentographie mit trägerfreiem 113Inm -HSA als klinische Methode eingeführt. Vor Amniocentesen und bei Verdacht auf Placenta praevia werden Placentographien geschrieben. Den Schwangeren wird eine Aktivität von 500 μCi in die Cubitalvene injiziert. Die der Aktivität entsprechende Indiummenge ist kleiner als 0,1 ng. Die fetale Strahlenbelastung liegt unter lOmrad. Bei Anwendung von 113Inm-HSA entfällt eine Blockade der mütterlichen und fetalen Schilddrüsen. Die genaue Abgrenzung einer Placenta praevia wird nicht durch eine Blasenaktivität beeinträchtigt.Es wurden bisher 19 Placentalokalisationen durchgeführt. In allen Fällen konnte der Placentasitz eindeutig festgestellt werden. Bedingt durch die lange Liegezeit beim Aufnehmen eines Szintigramms kam es in zwei Fällen zu einem Vena-Cava-Kompressions-Syndrom. Zur Verhinderung dieser klinischen Zwischenfälle werden inzwischen Placentographien mit der Anger-Kamera aufgenommen. Mit Hilfe des divergierenden Kollimators konnte der gesamte Abdominalbereich erfaßt werden. Die Aufnahmezeit konnte auf 7 — 10 Minuten verkürzt werden. Die intravenöse injizierte Aktivität betrug bei dieser Methode ebenfalls 500 μCi. Der diagnostische Aussagewert der Kamerabilder ist szintigraphischen Aufnahmen gleichwertig.


Sign in / Sign up

Export Citation Format

Share Document