Predicted Gain and Functional Gain With Transcranial Routing of Signal Completely-in-the-Canal Hearing Aids

2003 ◽  
Vol 12 (2) ◽  
pp. 84-90 ◽  
Author(s):  
Marc A. Fagelson ◽  
Colleen M. Noe ◽  
Owen D. Murnane ◽  
Jennifer S. Blevins

Transcranial routing of signal (TCROS) was accomplished using completely-in-the-canal (CIC) hearing aids in 5 profoundly unilaterally hearing-impaired individuals. The functional gain realized by the participants far exceeded the gain predicted by measuring the acoustic output and real ear aided response of the hearing aids. The difference between predicted and functional gain increased with signal frequency and was attributed at least in part to mechanical vibration of the hearing aid in the external canal. Implications for fitting unilateral hearing loss using TCROS amplifying systems are discussed.

1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Revista CEFAC ◽  
2019 ◽  
Vol 21 (1) ◽  
Author(s):  
Lidiéli Dalla Costa ◽  
Sinéia Neujahr dos Santos ◽  
Maristela Julio Costa

ABSTRACT Purpose: to investigate speech recognition in silence and in noise in subjects with unilateral hearing loss with and without hearing aids, and to analyze the benefit, self-perception of functional performance, satisfaction and the use of hearing aids in these subjects. Methods: eleven adults with unilateral, mixed and sensorineural, mild to severe hearing loss participated in this study. Speech recognition was evaluated by the Brazilian Portuguese sentences lists test; functional performance of the hearing was assessed by using the Speech Spatial and Qualities of Hearing Scale questionnaire; satisfaction was assessed by the Satisfaction with Amplification in Daily Life questionnaire, both in Brazilian Portuguese; and to assess the use of hearing aids, the patient's report was analyzed. Results: the adaptation of hearing aids provided benefits in speech recognition in all positions evaluated, both in silence and in noise. The subjects did not report major limitations in communication activities with the use of hearing aids. They were satisfied with the use of sound amplification. Most of the subjects did not use hearing aids, effectively. The discontinuity of hearing aids use can be justified by the difficulty on perceiving participation’s restriction caused by hearing loss, as well as the benefit of the hearing aid, besides the concern with batteries’ costs and aesthetic aspects. Conclusion: although showing benefits in speech recognition, in silence and in noise, and satisfaction with sound amplification, most subjects with unilateral hearing loss do not effectively use hearing aids.


1995 ◽  
Vol 4 (1) ◽  
pp. 52-59 ◽  
Author(s):  
Michael Valente ◽  
Lisa G. Potts ◽  
Maureen Valente ◽  
Joel Goebel

Eight subjects with unilateral hearing loss were fitted with wireless CROS and transcranial BTE CROS hearing aids. Results revealed that two subjects preferred the BTE transcranial CROS; four subjects preferred the wireless CROS; one subject found both hearing aid systems to be equally satisfactory; and one subject rejected both CROS fittings. In addition, a fitting strategy is introduced using probe microphone analysis to: (a) measure trans-cranial thresholds (TCT) in the unaidable ear in dB SPL measured near the eardrum, and (b) determine the sensation level of the real ear aided response (REAR-TCT) for uncorrected and corrected speech-weighted noise. The results highlight some of the difficulties associated with successfully fitting a transcranial CROS hearing aid.


2018 ◽  
Vol 29 (04) ◽  
pp. 300-312 ◽  
Author(s):  
Nicola E. Gallagher ◽  
Jayne V. Woodside

AbstractDespite a high prevalence of age-related hearing loss in older people, there is an unexplained low level of hearing aid adoption and use. Further research is required to determine the reason because hearing aids can vastly improve the quality of life for those with hearing loss.The aim of this study was to explore factors associated with hearing aid adoption and use, and to determine whether these differed between groups with different hearing aid use behaviors.Individual face-to-face semistructured interviews.Three groups of older people with hearing loss in Northern Ireland were recruited: (1) regular hearing aid users (n = 12), (2) irregular hearing aid users (n = 10), and (3) hearing aid nonowners (n = 10).Qualitative thematic analysis, using principles of grounded theory, was used to code the data and extract emerging themes for each of the three groups to distinguish similarities and differences between the groups. One-way analysis of variance and χ 2 tests were used to determine the difference in continuous and categorical variables, respectively, between the three groups.Similar themes emerged across the three groups: the complexity of low hearing aid use and attitudes to hearing loss/hearing aid use. A third theme, inadequacy of audiology services, was identified in both groups using hearing aids. Older age people having more severe hearing loss and longer duration of hearing aid ownership were associated with greater hearing aid adoption and use.Similar themes emerged from qualitative analysis across groups of people with hearing loss. More information for those with hearing loss and those with hearing aids and scheduled follow-up appointments for those with hearing aids are essential to improve hearing aid adoption and use in older people. Further research should focus on the most suitable methods of distributing this information and how often follow-up appointments should take place to achieve optimal hearing aid adoption and use.


2019 ◽  
Vol 28 (2) ◽  
pp. 274-284 ◽  
Author(s):  
Elizabeth Convery ◽  
Gitte Keidser ◽  
Louise Hickson ◽  
Carly Meyer

Purpose Hearing loss self-management refers to the knowledge and skills people use to manage the effects of hearing loss on all aspects of their daily lives. The purpose of this study was to investigate the relationship between self-reported hearing loss self-management and hearing aid benefit and satisfaction. Method Thirty-seven adults with hearing loss, all of whom were current users of bilateral hearing aids, participated in this observational study. The participants completed self-report inventories probing their hearing loss self-management and hearing aid benefit and satisfaction. Correlation analysis was used to investigate the relationship between individual domains of hearing loss self-management and hearing aid benefit and satisfaction. Results Participants who reported better self-management of the effects of their hearing loss on their emotional well-being and social participation were more likely to report less aided listening difficulty in noisy and reverberant environments and greater satisfaction with the effect of their hearing aids on their self-image. Participants who reported better self-management in the areas of adhering to treatment, participating in shared decision making, accessing services and resources, attending appointments, and monitoring for changes in their hearing and functional status were more likely to report greater satisfaction with the sound quality and performance of their hearing aids. Conclusion Study findings highlight the potential for using information about a patient's hearing loss self-management in different domains as part of clinical decision making and management planning.


2008 ◽  
Vol 18 (1) ◽  
pp. 4-9 ◽  
Author(s):  
Leisha Eiten ◽  
Dawna Lewis

Background: For children with hearing loss, the benefits of FM systems in overcoming deleterious effects of noise, distance, and reverberation have led to recommendations for use beyond classroom settings. It is important that audiologists who recommend and fit these devices understand the rationale and procedures underlying fitting and verification. Objectives: This article reviews previousguidelines for FM verification, addresses technological advances, and introduces verification procedures appropriate for current FM and hearing-aid technology. Methods: Previous guidelines for verification of FM systems are reviewed. Those recommendations that are appropriate for current technology are addressed, as are procedures that are no longer adequate for hearing aids and FM systems utilizing more complex processing than in the past. Technological advances are discussed, and an updated approach to FM verification is proposed. Conclusions: Approaches to verification andfitting of FM systems must keep pace with advances in hearing-aid and FM technology. The transparency approach addressed in this paper is recommended for verification of FM systems coupled to hearing aids.


1968 ◽  
Vol 11 (1) ◽  
pp. 204-218 ◽  
Author(s):  
Elizabeth Dodds ◽  
Earl Harford

Persons with a high frequency hearing loss are difficult cases for whom to find suitable amplification. We have experienced some success with this problem in our Hearing Clinics using a specially designed earmold with a hearing aid. Thirty-five cases with high frequency hearing losses were selected from our clinical files for analysis of test results using standard, vented, and open earpieces. A statistical analysis of test results revealed that PB scores in sound field, using an average conversational intensity level (70 dB SPL), were enhanced when utilizing any one of the three earmolds. This result was due undoubtedly to increased sensitivity provided by the hearing aid. Only the open earmold used with a CROS hearing aid resulted in a significant improvement in discrimination when compared with the group’s unaided PB score under earphones or when comparing inter-earmold scores. These findings suggest that the inclusion of the open earmold with a CROS aid in the audiologist’s armamentarium should increase his flexibility in selecting hearing aids for persons with a high frequency hearing loss.


2020 ◽  
Author(s):  
Willy Nguyen ◽  
Miseung Koo ◽  
Seung Ha Oh ◽  
Jun Ho Lee ◽  
Moo Kyun Park

BACKGROUND Underuse of hearing aids is caused by several factors, including the stigma associated with hearing disability, affordability, and lack of awareness of rising hearing impairment associated with the growing population. Thus, there is a significant opportunity for the development of direct-to-consumer devices. For the past few years, smartphone-based hearing-aid apps have become more numerous and diverse, but few studies have investigated them. OBJECTIVE This study aimed to elucidate the electroacoustic characteristics and potential user benefits of a selection of currently available hearing-aid apps. METHODS We investigated the apps based on hearing-aid control standards (American National Standards Institute) using measurement procedures from previous studies. We categorized the apps and excluded those we considered inefficient. We investigated a selection of user-friendly, low-end apps, EarMachine and Sound Amplifier, with warble-tone audiometry, word recognition testing in unaided and aided conditions, and hearing-in-noise test in quiet and noise-front conditions in a group of users with mild hearing impairment (n = 7) as a pilot for a future long-term investigation. Results from the apps were compared with those of a conventional hearing aid. RESULTS Five of 14 apps were considered unusable based on low scores in several metrics, while the others varied across the range of electroacoustic measurements. The apps that we considered “high end” that provided lower processing latencies and audiogram-based fitting algorithms were superior overall. The clinical performance of the listeners tended to be better when using hearing aid, while the low end hearing-aid apps had limited benefits on the users. CONCLUSIONS Some apps showed the potential to benefit users with limited cases of minimal or mild hearing loss if the inconvenience of relatively poor electroacoustic performance did not outweigh the benefits of amplification.


Author(s):  
Yu-Hsiang Wu ◽  
Elizabeth Stangl ◽  
Octav Chipara ◽  
Anna Gudjonsdottir ◽  
Jacob Oleson ◽  
...  

Abstract Background Ecological momentary assessment (EMA) is a methodology involving repeated surveys to collect in-situ self-reports that describe respondents' current or recent experiences. Audiology literature comparing in-situ and retrospective self-reports is scarce. Purpose To compare the sensitivity of in-situ and retrospective self-reports in detecting the outcome difference between hearing aid technologies, and to determine the association between in-situ and retrospective self-reports. Research Design An observational study. Study Sample Thirty-nine older adults with hearing loss. Data Collection and Analysis The study was part of a larger clinical trial that compared the outcomes of a prototype hearing aid (denoted as HA1) and a commercially available device (HA2). In each trial condition, participants wore hearing aids for 4 weeks. Outcomes were measured using EMA and retrospective questionnaires. To ensure that the outcome data could be directly compared, the Glasgow Hearing Aid Benefit Profile was administered as an in-situ self-report (denoted as EMA-GHABP) and as a retrospective questionnaire (retro-GHABP). Linear mixed models were used to determine if the EMA- and retro-GHABP could detect the outcome difference between HA1 and HA2. Correlation analyses were used to examine the association between EMA- and retro-GHABP. Results For the EMA-GHABP, HA2 had significantly higher (better) scores than HA1 in the GHABP subscales of benefit, residual disability, and satisfaction (p = 0.029–0.0015). In contrast, the difference in the retro-GHABP score between HA1 and HA2 was significant only in the satisfaction subscale (p = 0.0004). The correlations between the EMA- and retro-GHABP were significant in all subscales (p = 0.0004 to <0.0001). The strength of the association ranged from weak to moderate (r = 0.28–0.58). Finally, the exit interview indicated that 29 participants (74.4%) preferred HA2 over HA1. Conclusion The study suggests that in-situ self-reports collected using EMA could have a higher sensitivity than retrospective questionnaires. Therefore, EMA is worth considering in clinical trials that aim to compare the outcomes of different hearing aid technologies. The weak to moderate association between in-situ and retrospective self-reports suggests that these two types of measures assess different aspects of hearing aid outcomes.


1999 ◽  
Vol 8 (1) ◽  
pp. 40-46 ◽  
Author(s):  
Melisa R. Ellis ◽  
Michael K. Wynne

The loudness growth in 1/2-octave bands (LGOB) procedure has been shown previously to provide valid estimates of loudness growth for adults with normal hearing and those with hearing loss (Allen, Hall, & Jeng, 1990), and it has been widely incorporated into fitting strategies for adult hearing aid users by a hearing aid manufacturer. Here, we applied a simple modification of LGOB to children and adults with normal hearing and then compared the loudness growth functions (as obtained from end-point data) between the two age groups. In addition, reliability data obtained within a single session and between test sessions were compared between the two groups. Large differences were observed in the means between the two groups for the lower boundary values, the upper boundary values, and the range between boundaries both within and across all frequencies. The data obtained from children also had greater variance than the adult data. In addition, there was more variability in the data across test sessions for children. Many test-retest differences for children exceeded 10 dB. Adult test-retest differences were generally less than 10 dB. Although the LGOB with the modifications used in this study may be used to measure loudness growth in children, its poor reliability with this age group may limit its clinical use for children with hearing loss. Additional work is needed to explore whether loudness growth measures can be adapted successfully to children and whether these measures contribute worthwhile information for fitting hearing aids to children.