scholarly journals Analysis of the influence of zero potential live operation on protection

2020 ◽  
Vol 152 ◽  
pp. 03004
Author(s):  
Qi Yang ◽  
Zhenyu Wang ◽  
Liang Zhu ◽  
Li Xu ◽  
Chaohui Zhen

In the case of live working in the distribution network, a live method of live working that satisfies the requirements for personal safety and power supply reliability needs to be studied, because of the serious safety accidents caused by misuse and weak safety awareness. Based on the analysis of singlephase buck symmetrical operation characteristics, a new method of zero-potential live working of distribution network based on injection current is proposed. By injecting current into the neutral point, the zero-sequence voltage is regulated so that the neutral point voltage is equal to the value of the operating phase line voltage drop minus the operating phase power supply voltage, ensuring that the operating point voltage is zero. Based on the principle of current fast-break protection and time-limited overcurrent protection, it is analyzed that the zero-potential uninterruptible operation method of the distribution network will not affect the distribution network protection. Finally, the system model is established based on the MATLAB. The simulation verifies the feasibility of the method by the operating phase voltage curve and the correctness of the protection impact analysis by comparing the non-working phase current curve with the protection setting.

2011 ◽  
Vol E94-C (6) ◽  
pp. 1072-1075
Author(s):  
Tadashi YASUFUKU ◽  
Yasumi NAKAMURA ◽  
Zhe PIAO ◽  
Makoto TAKAMIYA ◽  
Takayasu SAKURAI

2016 ◽  
Vol E99.C (10) ◽  
pp. 1219-1225
Author(s):  
Masahiro ISHIDA ◽  
Toru NAKURA ◽  
Takashi KUSAKA ◽  
Satoshi KOMATSU ◽  
Kunihiro ASADA

2015 ◽  
Vol 9 (1) ◽  
pp. 253-262
Author(s):  
Liu Zhongfu ◽  
Zhang Junxing ◽  
Shi Lixin ◽  
Yang Yaning

As for the wide application of arc suppression coil to the grounding in neutral point of mine high voltage grid, grid leakage fault rules and harmonic characteristics of the neutral point grounding system through arc suppression coil are analyzed, the selective leakage protection program “zero-sequence voltage starts, fifth harmonics of grid zerosequence voltage and zero-sequence current are extracted for phase comparison” is proposed, and corresponding fifth harmonic extraction circuit and power direction discrimination circuit are designed. The experimental results show that the protective principle applies not only to the neutral point insulated power supply system, but also to the power supply system in which neutral point passes arc suppression coil, which can solve selective leakage protection problems under different neutral grounding ways, improving the reliability of selective leakage and guaranteeing the stability of the action value.


1993 ◽  
Vol 29 (15) ◽  
pp. 1324 ◽  
Author(s):  
L.E. Larson ◽  
M.M. Matloubian ◽  
J.J. Brown ◽  
A.S. Brown ◽  
M. Thompson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document