scholarly journals Effect of Spacing between Stone Columns on the Behavior of Soft Soil

2021 ◽  
Vol 318 ◽  
pp. 01006
Author(s):  
Zeena A. Al-Kazzaz ◽  
Moataz A. Al-Obaydi

Soil improvement by stone columns is extensively used, especially for the soft ones. This is because of their efficiency and no environmental impact. Several factors affect its efficiency in improving the mechanical properties of the soil, and the most important of these factors are the spacing, length, and diameter of the stone columns. In this study, the finite element method was used to study the impact of the spacing between the stone columns on the amount of settlement and the bearing capacity of the soil. The study comprises three different spaces (s) that were taken in relation to the columns’ diameter (d), which are (s/d= 3, 4, and 5). In addition, three types of the sectional shape of column involved circular, rectangular, and square sections with different lengths of (L/d=2, 4, 6, 8, and 10). The results showed that the spacing between the stone columns is effective when the vertical load is greater than 30 kN/m2, and below this, there is no effect of the spacing. In general, the settlement decreases, and the bearing capacity increases with the decrease in the spacing between the stone columns. The spacing becomes a more pronounced effect with the longer length of the stone columns. All sections of the stone columns with a short length of (L/d=2) showed the same settlement of 271 mm at a distance (s/d=5), which decreases by 7.4, 6.6, and 8.9% at a distance (s/d=3) for the circular, rectangular and square sections respectively. In the case of long columns (L/d=10), the settlement at (s/d=3) improves by about 27.5% which drop to about 18% at (s/d=5). A slight improvement in the soil's bearing capacity is associated with decreases in the spacing between the stone columns. The improvements in the bearing of soil treated with short columns (L/d=2) are 6.0, 6.5, and 4.7% for circular, rectangular, and square sections, respectively, when changing the distance from (s/d=5) to (s/d=3). Whereas they become greater when increasing the columns’ length to (L/d=10) to be 7.9, 9.2, and 6.4%.

2020 ◽  
Vol 857 ◽  
pp. 319-327
Author(s):  
Moataz A. Al-Obaydi ◽  
Zeena A. Al-Kazzaz

Stone columns have been used widely to improve the engineering properties of the weak soil. Most of the previous works considered a circular section for the stone columns. In the present study, finite element analysis has been carried out to investigate the effect of stone columns shape and length on the settlement and bearing capacity of soft soil. Accordingly, three types of cross sectional shape for stone columns have been selected which they are circular, rectangular, and square sections with equivalent area. Various length of columns are adopted with diameter of 0.75m that achieved length to diameter or equivalent diameter ratios (L/d=2, 4, 6, 8, and 10) of columns spacing (S/d=3). The results show that the stone columns has tangible effects on the settlement of the soil while has minor effects on the bearing capacity. The settlement of the treated soil with stone columns have L/d=2, reduces by 18.0, 17.3, and 19.3% for circular, rectangular , and square sections respectively. With increasing length of the columns to L/d=10, further reductions in the settlement obtained of (27.1, 28.1, and 27.0%). Bearing capacity of the soil increased slightly with length of the stone columns. Almost all cross sectional shapes of the columns give bearing capacity about same. The increased in the bearing capacity of the treated soil with stone columns have L/d=2, not exceeded 10% for all sectional types. The average increments in bearing capacity when L/d=10 are 12 and 15% at settlement 50 and 100mm respectively. Insignificant changes in bearing capacity upon increasing length of columns from L/d=2 to 10 of maximum 5%. The plastic zone recedes with the increasing length of the stone columns. Finally, from the results obtained, it can be concluded that the stone columns shape has negligible effects on the settlement and bearing capacity of the soil.


2019 ◽  
Vol 5 (3) ◽  
pp. 702 ◽  
Author(s):  
Mahdi O Karkush ◽  
Anwar Jabbar

A stone column is one of the soil improvement methods that are mainly used for improving the geotechnical behavior of soft soils. For deep improvement of soft soil, the floating stone columns are considered the best and effective economically which provide lateral confinement and drainage and longitudinal skin friction. In this study, six tests were carried out on the natural soft soil of undrained shear strength of 5.5 kPa improved by single and two linear distributed floating stone columns. The stone column dimensions are 30 mm in diameter and 180 mm in length and the stone column material is sand of high internal friction angle of 48°. The natural and improved soil samples are tested under isolated raft foundation of dimensions 120×120 mm subjected to vertical static and cyclic loading of frequency 2Hz and continued for 50 seconds. The results showed a significant improvement in soil bearing capacity when reinforced with stone columns despite the small area replacement ratio, where the bearing capacity of improved soil increased by 120 to 145%. The compressibility of improved soil decreased by 57 to 86% in comparison with that of natural soft soil. Also, the floating stone columns reduced the porewater pressure, where the stone columns considered efficient in providing short drainage pathways. This can be one of the reasons why soil reinforced with floating stone columns hold higher cyclic and static stresses regardless the end bearing of stone columns.


Author(s):  
Jakub Stacho ◽  
Monika Sulovska

Stone columns made of coarse-grained materials and crushed stone are one of the most-used technologies for soil improvement all over the world. Stone columns improve the strength and deformation properties of subsoil and reduce the time required for the consolidation of fine-grained soils. The impact of the improvement depends on the properties of the original subsoil as well as the properties of the coarse-grained materials used for the stone columns. The article deals with the effects of the properties of coarse-grained materials for stone columns on the settlement and consolidation times of improved subsoil for the foundation of a factory. Numerical modeling as a 2D task was performed using Plaxis geotechnical software. The numerical analysis included two methods of modeling stone columns in a plane strain model, i.e., one method often used by practical engineers in the region of Slovakia, and one modified method, which allowed for a more accurate determination of the final settlement and consolidation time. The method modeled stone columns as continuous walls, and the compaction of the soil between the stone columns was taken into account. The results showed that the type of coarse-grained material can significantly affect the final settlement and time of consolidation. Stone columns made of quarry stone were suitable in the given geological conditions regardless of the design of the mesh, while stone columns made of pebble gravel were suitable only with a mesh of 1.5 x 1.5 m.


Author(s):  
Nahla Mohammed Salim ◽  
Shatha Hasan ◽  
Kawther Al-Soudany

Many researchers’ studies have shown that stone column is the best material to use to improve the bearing capacity of clayey soils. There are millions of waste volumes resulting from daily human activities. This excess waste leads to disposal problems and also causes environmental contamination and health risks. Demolished concrete is such one waste material that is produced from building demolition in Baghdad, Iraq. This paper describes experimental work conducted at the University of Technology that was carried out to investigate the improved bearing capacity of soft clay using crushed stone, followed by replacing crushed stone with concrete waste with the same relative density and grain size. The replacement was carried using waste concrete with different percentages corresponding to 25%, 50%, 75%, and 100%. The main conclusion drawn is that the bearing capacity increased to 119% by using crushed stone column, while the bearing capacity increased to 155% by using 100% of crushed concrete waste.


2015 ◽  
Vol 15 (2) ◽  
pp. 04014043 ◽  
Author(s):  
M. Etezad ◽  
A. M. Hanna ◽  
T. Ayadat

Author(s):  
M Zaki ◽  
Wardani SPR ◽  
Muhrozi Muhrozi

<p><em>Construction on soft soil, often creates problems. The Semarang North Ring Bridge and Kali Jajar Bridge are the Recent soft Marine Alluvium zones located in the Pantura area which have very soft soil characteristics with a depth of more than -30.0 meters this has resulted in a very large settlement due to very small grains, flood, rob, pore water pressure increases so that the shear strength of the soil will be small, the compression is large and the permeability coefficient is small so that if the construction load exceeds the critical bearing capacity, the damage to the foundation soil will occur. To get the increase in soil bearing capacity, it can be achieved by changing the properties of the soil from the shear angle (</em>f<em>), cohesion (c) and unit weight (</em>g<em>). The settlement can be reduced by increasing the cavity density from the compression of the soil particles (Wesley, 1977). Soil improvement takes a long time, aiming to increase shear resistance so that it requires a fast time in this case is to use Pre-Fabricated Vertical Drain (Bowles 1981). The results of the analysis of the pattern of decline and the effectiveness of the use of PVD (pre-fabricated vertical drain) at the Oprit Bridge in the two research locations have the same decrease in the range of the same heap height at (H = 4 meters) there is a decrease of 117.53 cm at 64 months on the bridge. Kali Jajar (STA. 3 + 200) and there was a decrease of 268.94 cm at 37 months at the Semarang North Ring Bridge</em></p>


2020 ◽  
Vol 53 (2D) ◽  
pp. 1-18
Author(s):  
Bui Truong Son

The point foundation method is the head enlarged cement deep mixing columns with high-quality control which can be used for soft ground improvement. The article aims to present the application of this method to treat soft soil for the foundation of Samse Vina factory, Ninh Binh province. The thickness of soft soil varies from 5.4 m to 7.4 m with high compressibility and low shear strength. Thus, point foundation was used to improve this layer. The prediction methods of soil bearing capacity and the settlement on the point foundation were calculated. After the treatment of soil, the unconfined compression strength of the point foundation column was determined and the static compression test for the point foundation column was also performed. The research results show that this method can significantly reduce the settlement of shallow footing and improved the bearing capacity of the soil. The final settlement of shallow footing was smaller than 2.54 cm and the bearing capacity of soil treatment can be satisfied with the requirement of construction building. This is a successful case of the application of point foundation to improve soft soil in Vietnam.


2018 ◽  
Vol 149 ◽  
pp. 02008
Author(s):  
Ramdane Bahar ◽  
Omar Sadaoui ◽  
Fatma Zohra Yagoub

The coastal city of Bejaia, located 250 kilometers east of the capital Algiers, Algeria, is characterized by soft soils. The residual grounds encountered on the first 40 meters usually have a low bearing capacity, high compressibility, insufficient strength, and subject to the risk of liquefaction. These unfavorable soil conditions require deep foundations or soil improvement. Since late 1990s, stone columns technique is used to improve the weak soils of the harbor area of the city. A shallow raft foundation on soft soil improved by stone columns was designed for a heavy storage steel silo and two towers. The improvement of 18m depth have not reached the substratum located at 39m depth. The stresses transmitted to the service limit state are variable 73 to 376 kPa. A rigorous and ongoing monitoring of the evolution of loads in the silo and settlements of the soil was carried out during 1400 days that is from the construction of foundations in 2008 to 2012. After the loading of the silo in 2010, settlement occurred affecting the stability of the towers due to excessive differential settlements. Consequently, the towers were inclined and damaged the transporter. This paper presents and discusses the experience feedback of the behavior of these structures. Numerical calculations by finite elements have been carried and the results are compared with the measurements.


2011 ◽  
Vol 94-96 ◽  
pp. 190-195 ◽  
Author(s):  
Shu Li Wang ◽  
Man Gen Mu ◽  
Jing Yu Dai ◽  
Xiao Huan Hu

A parametric study of an foundation on soft soils reinforced with stone columns is performed using Phase2D. The real foundation is modeled and its bearing capacity is decided by the columns and their surrounding soft soil. The following parameters are analysed: the replacement area ratio, the deformability, mean stress, absolute horizontal (vertical) displacement, volumetric strain, maximum shear strain of the foundation. Based on the results of this study, a new design method is proposed: for decreasing the settlement and satisfying bearing capacity, increasing the replacement area ratio is good idea.


Sign in / Sign up

Export Citation Format

Share Document