scholarly journals Sound Scattering Properties of Surfaces with Diffusers

2020 ◽  
Vol 320 ◽  
pp. 00024
Author(s):  
Marina Lavrova ◽  
Nikolay Kanev

This article compares the values of the normal scattering coefficient measured in a model experiment for two types of diffusers placed on a rigid surface. Wooden diffusers of cubic and pyramidal shapes were tested in a scale model of a room with dimensions of 0.7x0.4x0.4 m. Sound decay curves were measured at frequencies of 4kHz and 8kHz. Two large walls were covered with a porous absorber, on the third, in certain combinations, the investigated diffusers with a characteristic size of 3.5 cm were placed, the number of which varied from 0 to 29. The idea of the applied method is that the sound decay curve in a room with a non-diffuse sound field depends significantly from the scattering properties of surfaces. The decay curve was measured with different numbers of the diffusers on the test wall, which made it possible to determine the influence of the shape of the diffusers and their number on the value of the normal scattering coefficient. According to the results of the measurements a high scattering ability of cubic elements was revealed in comparison with pyramidal ones.

2021 ◽  
Vol 11 (9) ◽  
pp. 3781
Author(s):  
Takumi Yoshida ◽  
Yasutaka Ueda ◽  
Norimasa Mori ◽  
Yumi Matano

This paper presents a crossed rib diffuser (CRD) as an effective tool for room acoustic control. We performed an experimental investigation of its effectiveness using a specimen manufactured for this trial. The CRD is constructed by overlapping two one-dimensional (1D) periodic rib diffusers with different specifications so that they are crossed at non-right angles. The CRD achieves a higher scattering coefficient than 1D periodic rib diffusers in a wide band while maintaining the simple and friendly design of 1D periodic rib diffusers applicable to various architectural spaces. Moreover, inserting an absorbing layer between upper and lower ribs of the CRD, (CRD-A) yields a high broadband absorption coefficient. We first evaluated the random-incidence scattering coefficient of CRD using a 1/5 scaled model in comparison with those of 1D periodic diffusers assessed with a numerical method. Then, absorption coefficients for the CRD and the CRD-A were measured using a reverberation room. Subsequently, an experiment on a small meeting room with a 1D periodic rib diffuser, the CRD and the CRD-A was conducted to present performance of the CRD in room acoustic control. Impulse response measurements and evaluations of reverberation parameters (T20 and EDT) and speech clarity (D50) were conducted. Additionally, we present differences in structure of reflected sounds found for the flat wall, the CRD and the CRD-A visually using a four-channel sound field microphone.


2005 ◽  
Vol 49 ◽  
pp. 865-870
Author(s):  
Akinori NAKATA ◽  
Takashi NISHIZAWA ◽  
Junji ONISHI ◽  
Haruo SOEDA

2001 ◽  
Vol 105 (1053) ◽  
pp. 627-631
Author(s):  
P. Traub ◽  
F. Kennepohl ◽  
K. Heinig

Abstract Under the national research project, dubbed Turbotech II, in which MTU Aero Engines, DLR Institute of Propulsion Technology and EADS Corporate Research Centre participate, active noise control (ANC) has been tested with a scale model fan of one metre diameter for a high bypass ratio aeroengine. MTU’s task in this project was to develop a computer code to predict the sound field in the intake duct of the fan-rig by the use of active control. The primary objective of the numerical study was to specify numbers of actuators (loudspeakers) and error sensors (microphones) and their positioning to control the harmonic sound power, radiated upstream to the duct intake. The computer model is based on the geometry of an annular or circular duct of rigid walls and infinite length, containing a subsonic axial uniform flow. The modal amplitudes of the primary sound field are input data. The actuators are modelled by acoustic monopoles. Two control algorithms have been used for achieving the control objective. The first consists simply in the reduction of the in-duct mean squared pressures. The second, so called modal control, is designed to cancel dominant modes selectively. Numerical results are presented using a typical configuration of wall mounted actuators and error sensors in the form of a number of rings uniformly distributed along the length of the intake duct. Guidelines have also been derived to design a favourable configuration of actuators and sensors. The findings of the numerical study are compared with the results of the ANC tests.


Author(s):  
Heather L. Lai ◽  
Brian Hamilton

Abstract This paper investigates the use of two room acoustics metrics designed to evaluate the degree to which the linearity assumptions of the energy density curves are valid. The study focuses on measured and computer-modeled energy density curves derived from the room impulse response of a space exhibiting a highly non-diffuse sound field due to flutter echo. In conjunction with acoustical remediation, room impulse response measurements were taken before and after the installation of the acoustical panels. A very dramatic decrease in the reverberation time was experienced due to the addition of the acoustical panels. The two non-linearity metrics used in this study are the non-linearity parameter and the curvature. These metrics are calculated from the energy decay curves computed per octave band, based on the definitions presented in ISO 3382-2. The non-linearity parameter quantifies the deviation of the EDC from a straight line fit used to generated T20 and T30 reverberation times. Where the reverberation times are calculated based on a linear regression of the data relating to either −5 to −25 dB for T20 or −5 to −35 dB for T30 reverberation time calculations. This deviation is quantified using the correlation coefficient between the energy decay curve and the linear regression for the specified data. In order to graphically demonstrate these non-linearity metrics, the energy decay curves are plotted along with the linear regression curves for the T20 and T30 reverberation time for both the measured data and two different room acoustics computer-modeling techniques, geometric acoustics modeling and finite-difference wave-based modeling. The intent of plotting these curves together is to demonstrate the relationship between these metrics and the energy decay curve, and to evaluate their use for quantifying degree of non-linearity in non-diffuse sound fields. Observations of these graphical representations are used to evaluate the accuracy of reverberation time estimations in non-diffuse environments, and to evaluate the use of these non-linearity parameters for comparison of different computer-modeling techniques or room configurations. Using these techniques, the non-linearity parameter based on both T20 and T30 linear regression curves and the curvature parameter were calculated over 250–4000 Hz octave bands for the measured and computer-modeled room impulse response curves at two different locations and two different room configurations. Observations of these calculated results are used to evaluate the consistency of these metrics, and the application of these metrics to quantifying the degree of non-linearity of the energy decay curve derived from a non-diffuse sound field. These calculated values are also used to evaluate the differences in the degree of diffusivity between the measured and computer-modeled room impulse response. Acoustical computer modeling is often based on geometrical acoustics using ray-tracing and image-source algorithms, however, in non-diffuse sound fields, wave based methods are often able to better model the characteristic sound wave patterns that are developed. It is of interest to study whether these improvements in the wave based computer-modeling are also reflected in the non-linearity parameter calculations. The results showed that these metrics provide an effective criteria for identifying non-linearity in the energy decay curve, however for highly non-diffuse sound fields, the resulting values were found to be very sensitive to fluctuations in the energy decay curves and therefore, contain inconsistencies due to these differences.


2019 ◽  
Vol 111 ◽  
pp. 01082
Author(s):  
Toshio Yamanaka ◽  
Mari Kuranaga ◽  
Tatsunori Maeda ◽  
Haruto Kitakaze

The authors developed a new radiant air conditioning system named ceiling radiant textile air conditioning system with ceiling cassette unit of packaged air conditioner (PAC). The nonflammable textile is stretched under the ceiling with ceiling cassette units of PAC with a distance of around 30 cm. The aim of this study is to investigate the cooling performance of this new radiant system, so the experiments with full scale model were conducted for three system. The first system is “textile only”, the second system is “textile with guide for air return grille” and the third system is “textile with guide and opening for air return grille”. Airflow rate through textile is measured by tracer gas method. In all cases, the vertical temperature distribution is almost uniform, and the cooling effect of “textile with guide and opening for air return grille” is the largest. As for the radiant effect, two systems of “only textile” and “textile with guide for air return grille” are superior to “textile with guide and opening for air return grille”. The airflow rate trough textile is doubled when using guide, and increased by five times if the opening was provided under the guide.


1999 ◽  
Vol 105 (2) ◽  
pp. 1197-1197
Author(s):  
Koji Ishida ◽  
Kiyoshi Sugino ◽  
Hideki Tachibana
Keyword(s):  

Sign in / Sign up

Export Citation Format