The Development and Status of Eye Banking with Special Focus on the Commitment of LIONS Clubs

Author(s):  
Sibylle Katharina Scholtz ◽  
Gerd Uwe Auffarth ◽  
Olaf Hellwinkel ◽  
Daniel Kampik ◽  
Philip Christian Maier ◽  
...  

Abstract Background Ever since the first successful keratoplasty in 1905, there has been a need to store corneas for transplantation. R. Townley Paton founded the first eye bank in New York in 1944. With Helen Kellerʼs call in 1925 for LIONS to “constitute themselves Knights of the Blind in the crusade against darkness”, LIONS Clubs International has become involved in the establishment of eye banks worldwide. This paper presents the development of eye banking in general and with special attention to the support offered by LIONS Clubs. Methods Selective literature search through PubMed, Google Scholar and Google in close cooperation with the LIONS Eye Banks already established in Germany, LIONS Clubs International (USA) and the Julius Hirschberg Society (Austria). Analysis focused on the founding processes of 6 German eye banks and their current services. Results Filatov was the first to keep donor eyes in a cool, moist container for a few days. In 1973, Summerlin et al described the technique of organ culture for donor corneas, and McCarey & Kaufman described a liquid storage medium in 1974. LIONS Clubs International and their organisational structure first supported an eye bank in the US in 1952, outside America in Hong Kong in 1962 and in Germany in 1969. Funding is provided across all levels of LIONS as network support and material resources. In general, staff funding is not provided. Of the 88 eye banks operating worldwide today, 44 are called LIONS Eye Banks. 6 of the current 26 eye banks in Germany are operating under LIONS sponsorship and run by departments of ophthalmology at university medical centres. Although the number of transplants has increased in recent years due to new surgical techniques, the number of patients waiting for donor tissue is also growing as a result of the broadening indication. Conclusions Even today, the availability of donor corneas limits patient care. Eye banks help to meet the need for donor corneas. However, the techniques and technical equipment of eye banks must undergo continuous improvement. The local, national and international network of LIONS Clubs can assist in establishing these in order to facilitate legal requirements and structural developments. This support frequently lasts for many years, often triggers additional public commitment and is thus also a supporting element for the future development of eye banking in Germany.

Author(s):  
Francesco Aiello ◽  
◽  
Federico Genzano Besso ◽  
Giulio Pocobelli ◽  
Gabriele Gallo Afflitto ◽  
...  

AbstractTo investigate the impact of Coronavirus Disease-2019 lockdown on the Italian Eye Bank organization. In this national retrospective, multicentric, cohort study, data from the Italian Eye Bank during both the lockdown and the first month after the lockdown period were retrieved. We compared the Italian Eye Bank metrics with the same timeframe of 2019 and 2018. Data from 13 out of 13 (100%) Italian Eye Banks were included in the analysis. A statistically significant reduction in the number of donor corneas retrieved in 2020 was found as compared to the same period in 2019 and in 2018, respectively (2020 = 1284; 2019 = 3088; 2018 = 3221; ANOVA: p < 0.0001). Only 534 corneas have been distributed by Eye Banks during the COVID-19-lockdown period (2020 = 534; 2019 = 1220; 2018 = 1237. ANOVA: p < 0.0001). Similarly, the number of wasted corneas due to postponed or cancelled surgeries was 421, resulting in a considerable increase as compared to the previous 2 years (2020 = 421; 2019 = 67; 2018 = 84; ANOVA: p = 0.0035). Overall, 45 donor corneas were rejected in accordance with the guidance of the Italian National Health Institute Italian National Transplant Centre (CNT). SARS-CoV-2 pandemic has profoundly affected every social and medical field, including the Eye Bank procurement and distribution programs. The current data collected from all the Italian Eye Banks highlights the present and the forthcoming difficulties that the Eye Bank community is going to experience, as for the ongoing pandemic.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Mohit Parekh ◽  
Gianni Salvalaio ◽  
Alessandro Ruzza ◽  
Davide Camposampiero ◽  
Carlo Griffoni ◽  
...  

Descemet membrane endothelial keratoplasty (DMEK) is a corneal surgical technique which selectively replaces the damaged posterior part of the cornea with a healthy donor graft retaining the rest of the tissue intact. There is a need to validate and standardize the donor tissue before grafting due to certain issues that can lead to consequences such as graft failure due to poor endothelial cell count, higher mortality, detachment of the graft, or increased surgical expenses, time, and effort. Thus, prospective potential surgeons and eye banks should now aim at developing new improved surgical techniques in order to prepare the best suited, validated, precut, preloaded, and easy to transplant tissue to reduce pre- and postsurgical complications. This could be achieved by defining parameters like graft thickness, accepted mortality threshold of the endothelial cells, and behavior of grafts during preservation and transportation along with using more sophisticated instruments like microkeratome and femtosecond lasers for graft preparation. Thus, a rapport between the eye banks and the surgeons along with the advanced instruments can overcome this challenge to find the best possible solution for endothelial keratoplasty (EK).


2009 ◽  
Vol 5 (2) ◽  
pp. 81 ◽  
Author(s):  
Martijn WA van Geldorp ◽  
Johanna JM Takkenberg ◽  
Ad JJC Bogers ◽  
A Pieter Kappetein ◽  
◽  
...  

Over the next few decades the number of patients diagnosed with aortic stenosis is expected to rise as the population ages and the use of several diagnostic tools expands. This will result in a growing need for both medical and surgical treatment and stimulate the development of new diagnostic and surgical techniques. This article briefly describes the prevalence, pathogenesis and clinical presentation of patients with aortic stenosis and focuses on developments in diagnostic tools, treatment strategies and treatment modalities: the use of echocardiography, tissue Doppler imaging, stress testing and biomarkers is discussed, as well as timing of surgery and the role microsimulation can play in prosthesis selection. Furthermore, newly developed transcatheter valve implantation techniques and their possible role in treating ‘inoperable’ or ‘elderly’ patients are discussed.


2018 ◽  
Vol 69 (8) ◽  
pp. 2236-2239
Author(s):  
Marius Moga ◽  
Mark Edward Pogarasteanu ◽  
Dumitru Ferechide ◽  
Antoine Edu ◽  
Chen Feng Ifrim

Gout is a metabolic disease involving the impregnation of joints and other tissues with urate crystals. The onset is often brutal, and it manifests itself with pain and inflammation in the affected joint. The treatment usually involves rest, ice, NSAIDs and anti-gout medication. The long-term treatment involves medication and dietary changes. In the joint, urate crystals are deposited in the synovial, in the cartilage and in the menisci. In the arthroscopic practice, the gouty knee is a rare occurrence. We present a relevant case, that of a 57 years old patient without a prior gout diagnosis where we found urate crystal deposits covering the synovium, cartilage and meniscus, and we discuss the current and recent year Pub Med indexed literature in order to evaluate the possibilities for arthroscopic treatment of this pathology. We looked at the number of patients involved, their characteristics, and the surgical techniques used. We also looked at the temporal relation of the arthroscopic intervention to the recent gout attacks, and at the described lesions that were found. Also, we evaluated the papers for joint liquid analysis, gout drug treatment, and description of clinical aspects involved and associated lesions. Finally, we looked at the follow-up, at the functional scores used to monitor the patient�s evolution, at the associated medication and at the long-term outcomes, if described. We have found opinions to vary. In the end, we draw conclusions pertaining to the practical short-term and long-term use of knee arthroscopy in the treatment of gout.


2021 ◽  
pp. 112067212110143
Author(s):  
Luca Pagano ◽  
Kunal A Gadhvi ◽  
Giulia Coco ◽  
Matthew Fenech ◽  
Mitchell Titley ◽  
...  

Purpose: To compare the clinical outcomes of eye bank preloaded Descemet stripping automated endothelial keratoplasty (DSAEK) grafts and surgeon prepared. Methods: In this retrospective study, the data were obtained from two groups (a) surgeon cut DSAEK where tissue was prepared by the surgeon immediately before surgery, and (b) preloaded DSAEK tissue shipped to the surgeon after preparation by the eye bank. Standard DSAEK preparations using Moria microkeratome with single pass method were performed. For the tissues prepared by the eye banks, they were preloaded in an iGlide device and shipped in transport media. Standard DSAEK surgery using bimanual pull-through technique was performed for all the grafts. Air was used as a tamponade. Main outcome measures included best corrected visual acuity (BCVA) and rebubbling rate. Result: Out of 107 eyes of 101 patients that underwent DSAEK surgery, 33 tissues were prepared by the surgeon (sc-DSAEK), while 74 were prepared by the eye bank (pl-DSAEK). sc-DSAEK showed a rebubbling rate of 9.1%, compared to the 16.2% for the preloaded DSAEK ( p = 0.11). There was no statistical difference in postoperative BCVA between the two groups. Logistic regression analysis showed no association between detachment rate and cataract surgery, graft preparation method, graft diameter and reason for graft. Conclusion: Preloaded grafts have similar rebubbling rate and visual acuity achieved compared with surgeon prepared grafts.


2021 ◽  
Vol 10 (10) ◽  
pp. 2121
Author(s):  
Gerardo-Alfonso Márquez-Sánchez ◽  
Bárbara-Yolanda Padilla-Fernández ◽  
Miguel Perán-Teruel ◽  
Pedro Navalón-Verdejo ◽  
Sebastián Valverde-Martínez ◽  
...  

Background: When conservative management fails, patients with stress urinary incontinence (SUI) are considered for surgical treatment. Simpler, more economical and less invasive surgical techniques, such as the Remeex® system, have been developed. Objectives: To analyze the objective effectiveness of the Remeex® system in the treatment of male stress urinary incontinence. To study survival and complication rates of the Remeex® system in male SUI patients. Materials and methods: Prospective observational study between July 2015 and May 2020. Group A (n = 7; GA) patients with mild SUI. Group B (n = 22; GB) patients with moderate SUI. Group C (n = 18; GC) patients with severe SUI. Effectiveness was assessed by the number of patients achieving complete and partial dryness. Complete dryness was defined as patients using 0–1 safety pads per day; partial dryness as a >50% reduction in the number of pads used. Results were analyzed using descriptive statistics, Student’s t-test. Chi2, Fisher’s exact test, ANOVA, and multivariate analysis. Significance was set at p < 0.05. Results: Mean age 69.76 years, mean follow-up 33.52 months. Objective effectiveness was observed in 89.36% of patients with incontinence. The effectiveness was 85.71% in GA, 90.91% in GB and 88.89% in GC. There were no significant differences among groups (p = 1.0000). 34.04% of patients with an implant required at least one readjustment, while 66.00% did not require any. There were no significant differences among groups (p = 0.113) Chi2 = 4.352. 95.74% of implants remained in place by the end of follow-up. We observed complications in 17.02% of patients. Conclusions: Remeex® system is an effective and safe method for male stress urinary incontinence treatment, regardless of the severity of the incontinence, with high survival and low complication and removal rates. System readjustments are required in one-third of the cases.


Cornea ◽  
1985 ◽  
Vol 4 (4) ◽  
pp. 256???262
Author(s):  
Emile J. Farge ◽  
Robert A. Fort
Keyword(s):  
Eye Bank ◽  

PEDIATRICS ◽  
1982 ◽  
Vol 70 (6) ◽  
pp. 982-986 ◽  
Author(s):  
Peter A. Gross ◽  
Gerald V. Quinnan ◽  
Pureza F. Gaerlan ◽  
Carolyn R. Denning ◽  
Anne Davis ◽  
...  

High concentrations of split-product vaccine (SPV) are more immunogenic than lower concentrations. These studies were verified with another influenza strain, B/Singapore/22/79. Two ether-treated SPVs were compared in 80 children and young adults. The vaccine strains were influenza A/Bangkok/79, A/Brazil/78, and B/Singapore /79; 44 patients received a high-dose SPV containing 7, 7, and 60 µg each of the respective hemagglutinins (HA) and 36 received a standard dose SPV containing 7, 7, and 7 µg of HA, respectively. Among persons initially seronegative by hemagglutination inhibition (HAI) tests, the geometric mean titer (GMT) in 15 recipients of one high dose was 97 vs GMT of 37 in 18 recipients of one standard dose (P &lt; .05). Furthermore, 87% of high-dose recipients had HAI titer ≥ 40 vs 44% of standard dose recipients. In initially seropositive persons, GMT in 29 recipients of one high dose was 170 vs GMT of 84 in 18 recipients of one standard dose (P &lt; .05). Immune response to the other two virus strains was comparable for the two vaccines. The reaction index for the high dose vaccine was 0.70 vs 0.45 for the standard dose (P = NS). An A/Bangkok epidemic struck the New York metropolitan area. The attack rate in unvaccinated matched sibling control subjects was 35% (15/43). There were no vaccine failures. In conclusion, in the small number of patients studied, a 60-µg HA dose of B/Singapore/79 was significantly more immunogenic than a standard 7-µg HA dose without an increase in reactogenicity.


1991 ◽  
Vol 7 (6) ◽  
pp. 478-478
Author(s):  
Paul J Dubord ◽  
Mark J Mannis
Keyword(s):  
Eye Bank ◽  

Sign in / Sign up

Export Citation Format