Detection of Asymptomatic Deep Vein Thrombosis by Real-Time B-Mode Ultrasonography in Hip Surgery Patients

1992 ◽  
Vol 68 (03) ◽  
pp. 257-260 ◽  
Author(s):  
Giancarlo Agnelli ◽  
Raul Volpato ◽  
Stefano Radicchia ◽  
Franca Veschi ◽  
Paolo Di Filippo ◽  
...  

SummaryThe aim of this study was to prospectively evaluate the accuracy of real-time B-mode ultrasonography in the diagnosis of asymptomatic proximal deep vein thrombosis (DVT) in hip surgery patients. Venography was adopted as the gold standard. We studied 100 consecutive patients undergoing hip surgery: 60 patients for hip fracture and 40 patients for elective hip replacement. Bilateral real-time B-mode ultrasonography was performed prior to bilateral venography. The two diagnostic procedures were performed on the same day by different investigators unaware of the assigned prophylatic regimen for DVT Compressibility of the vein segment was adopted as the single criterion for DVT. Venography was performed and judged by radiologists unaware of the ultrasonography results. In 13 limbs venography was either impossible to perform or not adequate for judgement. Ultrasonography and an adequate venography was obtained in 187 limbs. A venography proven DVT was observed in 49 limbs (26.2%) and a proximal DVT in 21 limbs (11.2%). All the patients were asymptomatic for DVT. The sensitivity and specificity of real time B-mode ultrasonography for proximal DVT were 57% (95% confidence interval: C. I. 36–80) and 99% (C. I. 99–100), respectively and the positive and negative predictive values were 93% (C.I. 73–100) and 95% (C.I. 91–97), respectively. The sensitivity and specificity for overall DVT were 25% (C.I. 11–38) and 99% (C.I. 97–100), respectively and the positive and negative predictive values were 92% (C. I. 73–100) and 79% (C.I. 76–85), respectively. Our data indicate that realtime B-mode ultrasonography for its high specificity could make venography unnecessary in patients with positive results. However, because of its low sensitivity it cannot be used for the screening of DVT in asymptomatic patients, nor can it replace venography for outcome measurements in clinical trials on DVT prophylaxis.

1989 ◽  
Vol 61 (03) ◽  
pp. 363-365 ◽  
Author(s):  
Lars C Borris ◽  
Hanne M Christiansen ◽  
Michael R Lassen ◽  
Agnete D Olsen ◽  
Peder Schøtt ◽  
...  

SummaryA prospective study compared real-time B-mode ultrasound examination with bilateral ascending phlebography in the diagnosis of postoperative deep vein thrombosis in 60 patients undergoing elective total hip replacement. The overall sensitivity and specificity of the ultrasound method were 54 and 91%, respectively, and the positive and negative predictive values were 83 and 69%, respectively. The rather low overall sensitivity of the ultrasound method in this study was due to difficulty in detecting thrombi smaller than 1 cm wherever they were located in the deep veins, and in diagnosing thrombi in the calf, regardless of their size. We conclude that real-time B-mode ultrasonography is a technique that can easily be used routinely for detection of postoperative DVT in hip surgery, but its sensitivity for proximal thrombosis (63%) is too low for it to be used alone.


2016 ◽  
Vol 23 (3) ◽  
pp. 221-228 ◽  
Author(s):  
Cristina Legnani ◽  
Michela Cini ◽  
Mirella Frascaro ◽  
Giuseppina Rodorigo ◽  
Michelangelo Sartori ◽  
...  

In patients presenting non-high clinical pretest probability (PTP), a negative d-dimer can exclude venous thromboembolism without imaging tests. However, each d-dimer assay should be validated in prospective studies. We evaluated an automated d-dimer immunoassay using the Sclavo Auto d-dimer (Sclavo Diagnostics Int, Sovicille, Italy) provided by Dasit Diagnostica (Cornaredo, Milan, Italy). Three hundred two consecutive outpatients suspected of leg deep vein thrombosis (DVT) with non-high PTP were included. The Sclavo Auto d-dimer assay was evaluated on 2 analyzers (Sysmex CA-7000 and Sysmex CS-2100; Sysmex Corporation, Kobe, Japan, provided by Dasit). The cutoff value (200 ng/mL) was established a priori. Prevalence of DVT was 11.9%. Since no false-negative patients were detected, the sensitivity and negative predictive values (NPVs) were 100% (sensitivity = CA-7000: 100% [95% confidence interval, CI: 93.3-100], CS-2100: 100% [95% CI: 93.3-100]; NPV = CA-7000: 100% [95% CI: 97.9-100], CS-2100: 100% [95% CI: 98.0-100]). Specificity was 65.4% (95% CI: 59.4-71.1) and 69.2% (95% CI: 63.3-74.7) for CA-7000 and CS-2100, respectively. Specificity increased when a higher cutoff value (234 ng/mL) was used for patients aged ≥60 years without compromising the safety. Assay reproducibility was satisfactory at concentrations near the cutoff value (total coefficient of variations <10%). In conclusion, the Sclavo Auto d-dimer assay was accurate when used for DVT diagnostic workup in outpatients with non-high PTP. Based on its high sensitivity and NPV, it can be used as a stand-alone test in outpatients with non-high PTP. Given its high specificity, the number of patients in whom further imaging techniques can be avoided increased, improving the yield of the test.


2018 ◽  
Vol 146 (5-6) ◽  
pp. 303-308
Author(s):  
Dragan Markovic ◽  
Dragan Vasic ◽  
Jelena Basic ◽  
Slobodan Tanaskovic ◽  
Slobodan Cvetkovic ◽  
...  

Introduction/Objective. Untreated deep vein thrombosis (DVT) is associated with a high risk of pulmonary embolism (PE), and false diagnosis of DVT results in unnecessary anticoagulant therapy, with a risk of bleeding. Accurate diagnosis of DVT and prompt therapy are essential to reduce the risk of thromboembolic complications. The aim of our study was to evaluate the sensitivity and specificity of three D-dimer tests (DD PLUS, HemosIL, and VIDAS) comparing to compression ultrasonography (CUS) examination. Methods. We observed 350 patients, some with different risk factors. The patients underwent the same protocol (evaluation of the patient?s history, physical examination, and D-dimer testing), and CUS was used as a reference for all the patients. According to Wells score, the patients were divided into groups with low, moderate, and high pretest probability (PTP). Results. Most of the examined patients were with moderate PTP. The CUS showed that there was the highest number of examined patients without DVT. Most of the examined patients with a positive CUS finding had proximal iliac and femoral DVT. VIDAS test was positive in the highest percentage in the group of patients with CUS-documented thrombosis. Conclusion. All three D-dimer tests used in our study had similar sensitivity and specificity. However, VIDAS test had higher levels of positive and negative predictive values comparing to the others. The comparison of three D-dimer tests by an ROC curve showed that VIDAS test has the highest overall statistical accuracy of all three D-dimer tests.


2006 ◽  
Vol 96 (07) ◽  
pp. 79-83 ◽  
Author(s):  
Wolfgang Korte ◽  
Michael Schwab ◽  
Rainer Zerback ◽  
Menno Huisman ◽  
Carl-Erik Dempfle ◽  
...  

SummaryD-dimer assays are efficient in the exclusion diagnostics of deep vein thrombosis (DVT) in patients without severe concomitant diseases. We have determined diagnostic sensitivity and specificity of a new point-of-care rapid assay for quantitative determination of D-dimer in heparinized whole blood in outpatients with suspected DVT. In 19 participating centers, 637 patients were included in the study, of which 77 were excluded, the majority because of inadequate documentation of analytical quality control measures. DVT was diagnosed in 223 of the remaining 560 patients by duplex ultrasound examination. The POC D-dimer assay showed a high sensitivity of 96.9% for the diagnosis of DVT and a high specificity of 60.8% at a pre-specified cutoff of 0.5 µg/ml. For Tina-quant D-dimer, sensitivity was slightly lower at 94.9%, with a specificity of 64.8%.The VIDAS D-dimer assay showed a sensitivity of 98.2%, but specificity was 40.7%. The area under the curve (AUC ± standard error, 95% confidence interval) was 0.879 ± 0.019 (0.845–0.909) for POC D-dimer, 0.908 ± 0.016 (0.877–0.934) for Tina-quant D-dimer, and 0.895± 0.018 (0.862–0.922) forVIDAS D-dimer. Differences were not statistically significant. The new whole blood POC D-dimer assay isa reliable tool for exclusion of DVT in symptomatic outpatients, displaying a comparable diagnostic performance as VIDAS D-dimer and Tina-quant D-dimer assays.Roche CARDIAC and TINA-QUANT are tradenames of Roche.


1996 ◽  
Vol 75 (02) ◽  
pp. 239-241 ◽  
Author(s):  
Alessandra Ascani ◽  
Stefano Radicchia ◽  
Pasquale Parise ◽  
Giuseppe G Nencl ◽  
Giancarlo Angelli

SummaryVenous thromboembolism is a leading cause of in-hospital postoperative morbidity and mortality. Postoperative deep vein thrombosis (DVT) is usually asymptomatic. A number of studies have consistently shown that the non invasive diagnostic methods are inaccurate in the screening of asymptomatic DVT. Failure of non invasive diagnostic methods to detect thrombi in asymptomatic patients has been suggested to be due to the features of thrombi in these patients. The aim of this study was to assess the distribution and the occlusiveness of thrombi in a series of 321 asymptomatic hip surgery patients with adequate bilateral venography of the lower limbs.Venography was performed 10 ± 1 days after hip surgery. DVT was found in 180 limbs (28.0%). The distribution of thrombi was as follows: 26 (14.4%) isolated proximal thrombi, 55 (30.6%) proximal and distal thrombi, 99 (55.0%) isolated calf thrombi. We found that 14 of the 81 proximal trombi (17.3%) involved the superficial femoral vein either as exclusive location or in association with calf veins. An involvement of common femoral, superficial femoral and popliteal vein was observed in 37 (45.7%), 39 (48.1%) and 44 (54.3%) cases of the 91 proximal DVT. These thrombi were non occlusive in 25 (67.6%), 22 (56.4%) and 26 (59.1%) limbs, respectively. An involvement of at least one peroneal, anterior tibial and posterior tibial veins was observed in 118,13 and 89 cases of the 220 distal thrombi. These thrombi were non occlusive in 61 (51.7%), 10 (76.9%) and 30 (33.7%) of the cases.We conclude that the majority of thrombi found in asymptomatic hip surgery patients are non occlusive. In view of this, non invasive diagnostic methods based upon venous flow measurement will be unlikely to improve the diagnosis of asymptomatic DVT. The high incidence of isolated superficial femoral vein thrombosis necessitates that real-time B-mode ultrasonography should be performed examining the entire proximal venous system.


1990 ◽  
Vol 64 (04) ◽  
pp. 497-500 ◽  
Author(s):  
Martin H Prins ◽  
Jack Hirsh

SummaryWe evaluated the evidence in support of the suggestion that the risk of deep vein thrombosis after hip surgery is lower with regional than with general anesthesia. A literature search was performed to retrieve all articles which reported on the incidence of postoperative thrombosis in both fractured and elective hip surgery. Articles were included if the method of anesthesia used was reported and if they used mandatory venography. Based upon the quality of study design the level of evidence provided by a study was graded.In patients who did not receive prophylaxis there were high level studies in elective and fractured hip surgery. All studies showed a statistically significantly lower incidence of postoperative deep vein thrombosis with regional anesthesia (relative risk reductions of 46-55%). There were no direct comparative studies in patients who received prophylaxis. However, between study comparisons did not show even a trend towards to lower incidence of postoperative thrombosis with regional anesthesia.


1991 ◽  
Vol 65 (01) ◽  
pp. 028-032 ◽  
Author(s):  
B Boneu ◽  
G Bes ◽  
H Pelzer ◽  
P Sié ◽  
H Boccalon

SummaryThis study was performed to determine the accuracy of D-Dimer fibrin derivatives, thrombin-antithrombin III (TAT) complexes and prothrombin fragments 1 + 2 (F 1 + 2) determinations for the diagnosis of deep vein thrombosis (DVT). One hundred and sixteen consecutive patients referred to the angiology unit of our hospital for a clinically suspected DVT were investigated. They were submitted to mercury strain gauge plethysmography and to ultrasonic duplex scanning examination; in cases of inconclusive results or of proximal DVT (n = 35), an ascending phlebography was performed. After these investigations were completed, the diagnosis of DVT was confirmed in 34 and excluded in 82. One half of the patients were already under anticoagulant therapy at the time of investigation. The 3 biological markers were assayed using commercially available ELISA techniques and the D-Dimer was also assayed with a fast latex method. The normal distribution of these markers was established in 40 healthy blood donors. The most accurate assay for the diagnosis of DVT was the D-Dimer ELISA which had both a high sensitivity (94%) and a high negative predictive value (95%). The D-Dirner latex, TAT complexes and F 1 + 2 were far less sensitive and provided negative predictive values which ranged between 78 and 85%. In spite of positive and significant correlations between the levels of ihe 3 markers, their association did not improve their overall accuracy for detecting D\/L Therefore, with the exception of the D-Dimer ELISA, these markers were of little value for the diagnosis of DVT in this specific population.


1993 ◽  
Vol 70 (02) ◽  
pp. 266-269 ◽  
Author(s):  
Giancarlo Agnelli ◽  
Benilde Cosmi ◽  
Stefano Radicchia ◽  
Franca Veschi ◽  
Enrico Boschetti ◽  
...  

SummaryImpedance plethysmography (IPG) has high sensitivity and specificity in patients with symptomatic deep vein thrombosis (DVT) while it fails to detect asymptomatic DVT. The aim of this study was to determine whether the features of thrombi such as location, size and occlusiveness could explain the different accuracy of IPG in symptomatic and asymptomatic DVT patients. One-hundred and seventeen consecutive outpatients with a clinical suspicion of DVT and 246 consecutive patients undergoing hip surgery were admitted to the study. In symptomatic patients IPG was performed on the day of referral, followed by venography, while in asymptomatic patients IPG was performed as a surveillance programme, followed by bilateral venography.A venography proved DVT was observed in 37% of the symptomatic patients and 34% of the asymptomatic limbs. A significantly higher proportion of proximal DVTs was found in symptomatic patients than in asymptomatic patients (78% vs 46%; p = 0.001). The mean Marder score, taken as an index of thrombus size, was significantly higher in symptomatic patients than in asymptomatic patients (19.0 vs 9.6; p = 0.0001). A significantly higher proportion of occlusive DVTs was observed in symptomatic than in asymptomatic patients (69% vs 36%; p = 0.001).We conclude that the unsatisfactory diagnostic accuracy of IPG in asymptomatic DVT is due to the high prevalence of distal, small and non occlusive thrombi. Such thrombi are unlikely to cause a critical obstruction of the venous outflow and therefore to produce a positive IPG.


1996 ◽  
Vol 75 (02) ◽  
pp. 242-245 ◽  
Author(s):  
Marie Magnusson ◽  
Bengt I Eriksson ◽  
Peter Kãlebo ◽  
Ramon Sivertsson

SummaryPatients undergoing orthopedic surgery are at high risk of developing deep vein thrombosis. One hundred and thirty-eight consecutive patients undergoing total hip replacement or hip fracture surgery were included in this study. They were surveilled with colour Doppler ultrasound (CDU) and bilateral ascending contrast phlebography. The prevalence of proximal and distal DVT in this study was 5.8% and 20.3% respectively.CDU has a satisfactory sensitivity in patients with symptomatic deep vein thrombosis, especially in the proximal region. These results could not be confirmed in the present study of asymptomatic patients. The sensitivity was 62.5% (95% confidence interval: C.I. 24-91%) and the specificity 99.6% (C.I. 98-100%) for proximal DVT; 53.6% (C.I. 34-73%) and 98% (C.I. 96-99%) respectively for distal thrombi. The overall sensitivity was 58.1% (C.I. 39-75%) and the specificity 98% (C.I. 96-99%). The positive predictive value was 83.3% (C.I. 36-99%) and 75% (C.I. 51-91%) for proximal and distal DVT respectively. The negative predictive value was 98.9% (C.I. 98-100%) and 94.9% (C.I. 92-98%) for proximal and distal DVT respectively. The results of this study showed that even with a highly specialised and experienced investigator the sensitivity of CDU was too low to make it suitable for screening purposes in a high risk surgical population.