Acid Débridement of Burns with Phosphoric-Acid Gel

1951 ◽  
Vol 244 (19) ◽  
pp. 705-709 ◽  
Author(s):  
Robert J. Schweitzer ◽  
Jacob T. Bradsher
Keyword(s):  
2019 ◽  
Vol 10 (4) ◽  
pp. 304-309
Author(s):  
Larissa Costa Santos ◽  
Ravana Angelini Sfalcin ◽  
Eugenio José Garcia ◽  
Fátima Antônia Aparecida Zanin ◽  
Aldo Brugnera Junior ◽  
...  

Introduction: Microleakage has been reported to cause dentin hypersensitivity because of the passage of bacteria and their products through the restoration-tooth interface and is one of the main reasons for replacement of restorations. CO2 laser can be used for treatment of dentin hypersensitivity. Thus, this study aimed to evaluate in vitro the microleakage in composite restorations following surface pretreatment with acid etching and CO2 laser. Methods: Twelve human caries-free primary molars were selected. Class II cavities were prepared on occlusal mesial and occlusal distal surfaces. Specimens were randomly divided into four groups (n=6): Group 1 (G1) – 37% phosphoric acid gel etching + Beautiful-Bulk Restorative – Giomer (Shofu Inc); Group 2 (G2) – 37% phosphoric acid gel etching + SDR Bulk-Fill Flow (Dentsply); Group 3 (G3) – CO2 laser irradiation + Beautiful-Bulk Restorative – Giomer (Shofu Inc); Group 4 (G4) – CO2 laser irradiation + SDR Bulk-Fill Flow (Dentsply). Surfaces were restored with bonding agent (Natural Bond DE, DFL). Specimens were cut longitudinally and immersed in 0.5% methylene blue solution for 4 hours. Microleakage scores were assessed under a magnifying glass at x3,5 and qualitatively analyzed by scanning electron microscope (SEM). Data were analyzed using nonparametric Wilcoxon test (P < 0.05). Results: Scores prevailed between 0 and 2, however, no statistically significant difference was found among the groups (P= 0.05). Conclusion: It could be concluded that all composite resins bulk fill did not show significant difference among them regarding microleakage using either CO2 laser or 37% phosphoric acid etching.


2008 ◽  
Vol 78 (6) ◽  
pp. 1089-1094 ◽  
Author(s):  
Tancan Uysal ◽  
Mustafa Ulker ◽  
Sabri Ilhan Ramoglu ◽  
Huseyin Ertas

Abstract Objective: To compare the in vitro microleakage of orthodontic brackets (metal and ceramic) between enamel-adhesive and adhesive-bracket interfaces at the occlusal and gingival sides produced by self-etching primer system with that of conventional acid etching and bonding. Materials and Method: Sixty freshly extracted human mandibular premolar teeth were used in this study. The teeth were separated into four groups of 15 teeth each and received the following treatments: Group 1, 37% phosphoric acid gel + Transbond XT liquid primer + stainless steel bracket; Group 2, Transbond Plus Self-Etching Primer (TSEP) + stainless steel bracket; Group 3, 37% phosphoric acid gel + Transbond XT liquid primer + ceramic bracket; Group 4, TSEP + ceramic bracket. After curing, specimens were further sealed with nail varnish, stained with 0.5% basic fuchsine for 24 hours, sectioned and examined under a stereomicroscope, and scored for microleakage for the enamel-adhesive and bracket-adhesive interfaces from both occlusal and gingival margins. Statistical analyses were performed using Kruskal-Wallis and Mann-Whitney U tests. Results: The gingival sides in all groups exhibited higher microleakage scores compared with those observed in occlusal sides for both adhesive interfaces. Enamel-adhesive interfaces exhibited more microleakage than did the adhesive-bracket interfaces. Brackets bonded with self-etching primer system showed significantly higher microleakage at the enamel-adhesive interface of the gingival side. Conclusions: TSEP causes more microleakage between enamel-adhesive interfaces, which may lead to lower bond strength and/or white-spot lesions.


1951 ◽  
Vol 8 (2) ◽  
pp. 168 ◽  
Author(s):  
Robert J. Schweitzer ◽  
Jacob T. Bradsher
Keyword(s):  

2020 ◽  
Vol 8 (3) ◽  
pp. 228-235
Author(s):  
César Cayo ◽  
◽  
Lorena Llancari ◽  
Román Mendoza ◽  
Luis Cervantes ◽  
...  
Keyword(s):  

2018 ◽  
Vol 6 (10) ◽  
pp. 12630-12640 ◽  
Author(s):  
Vidyanand Vijayakumar ◽  
Meena Ghosh ◽  
Arun Torris A. T. ◽  
Nikhil Chandran M. K. ◽  
Sanoop B. Nair ◽  
...  

2012 ◽  
Vol 37 (4) ◽  
pp. 386-396 ◽  
Author(s):  
THS Stape ◽  
MS Menezes ◽  
BCF Barreto ◽  
FHB Aguiar ◽  
LR Martins ◽  
...  

SUMMARY This study evaluated the effect of dentin pretreatment with 2% chlorhexidine (CHX) or 24% ethylenediamine tetra-acetic acid gel (EDTA) on the dentin microtensile bond strength (μTBS) of resin cements. Composite blocks were luted to superficial noncarious human dentin (n=10) using two resin cements (RelyX ARC [ARC] and RelyX U100 [U100]) and three dentin pretreatments (without pretreatment–control, CHX, and EDTA). CHX was applied for 60 seconds on the acid-etched dentin in the ARC/CHX group, and for the same time on smear layer-covered dentin in the U100/CHX group. EDTA was applied for 45 seconds on smear-covered dentin in the U100/EDTA group, and it replaced phosphoric acid conditioning in the ARC/EDTA group for 60 seconds. After storage in water for 24 hours, specimens were prepared for microtensile bond strength testing. The results were submitted to two-way analysis of variance (ANOVA) followed by Tukey test. ARC produced significantly higher μTBS (p&lt;0.05) compared to the U100, except when EDTA was used. For ARC, no pretreatment and CHX produced higher μTBS than EDTA. For U100, EDTA produced higher μTBS; no statistical difference occurred between CHX pretreatment and when no pretreatment was performed. While CHX did not affect immediate dentin bond strength of both cements, EDTA improved bond strength of U100, but it reduced dentin bond strength of ARC.


Pharmaceutics ◽  
2019 ◽  
Vol 11 (12) ◽  
pp. 643 ◽  
Author(s):  
Chihiro Naito ◽  
Hidemasa Katsumi ◽  
Kunio Yoneto ◽  
Mao Omura ◽  
Mayuko Nishidono ◽  
...  

For efficient transdermal delivery of alendronate (ALN) for anti-osteoporotic therapy, we developed a hyaluronic acid (HA) gel sheet that was prepared simply by enhancing HA noncovalent interactions using phosphoric acid and polyhydric alcohol (propanediol and glycerin). HA solution viscosity increased after addition of phosphoric acid, and the HA gel sheet formed after heated drying. The HA gel sheet could be converted to high viscosity state by addition of water. These results indicate that phosphoric acid enhances the noncovalent interactions of HA molecules. The HA gel sheet elicited no skin irritation over 7 days after a 24-h application. The permeation of ALN across rat and human skin was 109 and 7.17 µg/cm2, respectively, up to 24 h after application of the ALN-loaded HA gel sheet, which is sufficient for clinical treatment of osteoporosis. The bioavailability of ALN in rats was ~20% after application of the ALN-loaded HA gel sheet, and plasma calcium levels were effectively reduced 3 days after sheet application. Furthermore, in a rat osteoporosis model, the reduction in tibial bone density was suppressed by treatment with the ALN-loaded HA gel sheet. These results indicate that our phosphoric acid-mediated HA gel sheet is a promising transdermal formulation for efficient ALN delivery.


2003 ◽  
Vol 14 (3) ◽  
pp. 168-171 ◽  
Author(s):  
Marcelo Fava ◽  
Silvio Issáo Myaki ◽  
Victor Elias Arana-Chavez ◽  
Flavio Fava-de-Moraes

The aim of this in vitro study was to evaluate by scanning electron microscopy the morphological aspects of the enamel of primary teeth after etching with 36% phosphoric acid or a non-rinse conditioner. Ten naturally exfoliated anterior primary teeth were selected. The samples were subjected to prophylaxis with pumice paste and water using a low-speed hand piece. Etching was done on the buccal surface. Specimens were divided into 2 groups: G1 (n=10): etching with 36% phosphoric acid gel - Conditioner 36 (Dentsply) for 20 s, followed by water rinse for 15 s; G2 (n=10): etching with NRC - Non Rinse Conditioner (Dentsply) for 20 s, followed by air drying for 15 s. The samples were dehydrated, mounted on metal stubs, coated with gold and observed with Jeol JSM-6100 scanning electron microscope. Electron-micrographic analysis showed that both etching agents were effective for etching the enamel of primary teeth causing the formation of microporosities on the enamel surface, although the etching pattern was more effective with the use of 36% phosphoric acid gel.


2011 ◽  
Vol 36 (5) ◽  
pp. 545-553 ◽  
Author(s):  
A Saracoglu ◽  
M Özcan ◽  
O Kumbuloglu ◽  
M Turkun

SUMMARY Intraoral repairs of ceramic fixed-dental-prostheses (FDP) often include cervical recessions that require pretreatment of the exposed tooth surfaces either before or after the ceramic is conditioned with hydrofluoric (HF) acid gel. The sequence of repair protocol may cross-contaminate the exposed etched enamel or dentin surfaces during the application or rinsing process and thereby affect the adhesion. This study evaluated the influence of HF acid gel with two concentrations on bond strengths of composite to enamel and dentin. Human third molars (N=100, n=10 per group) with similar sizes were selected and randomly divided into 10 groups. Flat surfaces of enamel and dentin were created by wet ground finishing. Before or after the enamel (E) or dentin (D) was conditioned with phosphoric acid (P), substrate surfaces were conditioned with either 9.5% HF (HF9.5) or 5% HF (HF5). Subsequently, a bonding agent (B) was applied. The experimental groups by conditioning sequence were as follows where the first letter of the group abbreviation represents the substrate (E or D) followed by the acid type and concentration: group 1 (EPHF9.5), group 2 (EPHF5), group 3 (EHF9.5P), group 4 (EHF5P), group 5 (DPHF9.5), group 6 (DPHF5), group 7 (DHF9.5P), and group 8 (DHF5P). Group 9 (EPB) and group 10 (DPB) acted as the control groups. Repair resin was adhered incrementally onto the conditioned enamel and dentin in polyethylene molds. Each layer was photo-polymerized for 40 seconds. All specimens were thermocycled (×1000, 5°-55°C) and subjected to shear test (universal testing machine, 1 mm/min). Specimens that debonded during thermocycling were considered as 0 MPa. The bond strength data were analyzed using Kruskal-Wallis test and failure types using the chi-square test (α=0.05). Overall, the bond results (MPa) were lower on dentin than on enamel (p&lt;0.01). EPB (25.6 ± 6.6) and DPB (20.2 ± 4.9) control groups showed significantly higher results than those of other groups (p&lt;0.05). While higher mean bond strengths were obtained in group 1 (EPHF9.5) (11.5 ± 2.1) and group 2 (EPHF5) (7.3 ± 0.6), lower results were obtained when HF acid gels were applied prior to phosphoric acid (EHF9.5P: 5.0 ± 1.1, EHF5P: 3.6 ± 0.1) (p&lt;0.05). On dentin, the results were the lowest in group 8 (DHF5P: 1.5 ± 1.6), being significantly lower than those of group 5 (DPHF9.5) (p&lt;0.05). Scanning electron microscope (SEM) images revealed predominantly mixed failures with less than half of the composite left on both enamel and dentin surfaces (64 out of 80) (p&lt;0.05), indicating that in general, adhesion was not ideal. Contamination of the enamel or dentin surfaces with HF acid gel impairs the bond strength of composites. Considering both the bond strength results and failure types, when dental tissues are to be repaired next to ceramic, application of phosphoric acid before HF acid gel application can be recommended. HF acid gel concentration did not influence the results except on enamel.


2020 ◽  
Vol 53 (1) ◽  
pp. 16
Author(s):  
Erawati Wulandari ◽  
Faiqatin Cahya Ramadhani ◽  
Nadie Fatimatuzzahro

Background: Acid etching is a stage in obtaining bonds between composites and enamel. The application of acid to the enamel surface, however, can cause dissolution of hydroxyapatite and demineralisation of the enamel surface. Phosphoric acid, a strong acid, is an etching material that can reduce enamel hardness. Excessively reducing hardness can interfere with attachment to the restorative material. One medicinal plant that can be used as an alternative material in acid etching is tamarind. Purpose: This study aims to determine the effect of 5% tamarind extract gel on the tensile strength of composite resins. Methods: This is an experimental research study with a post-test-only control-group design. The study used 14 mandibular incisors. The labial part of the incisor was prepared using a diamond fissure bur with a diameter of 4 mm and a depth of 2 mm. The control group was then etched with 37% phosphoric acid gel, while the experimental group was etched with 5% tamarind extract gel. Bonding resins and micro-hybrid composite resins were applied, based on the manufacturers’ instructions. Next, a tensile strength test and seeing formation resin tags by scanning electron microscope (SEM) were performed. Data were analysed using an independent t-test (p < 0.05). Results: The average tensile strength of composite resins in the group etched with 5% tamarind extract gel was the same as in the 37% phosphoric acid group (p > 0.05). SEM images also show that enamel etched with 5% tamarind extract gel produced a tag similar to that etched with 37% phosphoric acid gel. Conclusion: 5% tamarind extract as an etching material can generate tensile strength of composite resin and trigger formation of resin tags in the same way as 37% phosphoric acid.


Sign in / Sign up

Export Citation Format

Share Document