Behavior of a Rocking Block Resting on a Rolling Isolation System

2017 ◽  
Vol 143 (8) ◽  
pp. 04017045 ◽  
Author(s):  
P. S. Harvey
2017 ◽  
Vol 11 (1) ◽  
pp. 217-236
Author(s):  
Panayiotis C. Roussis ◽  
Spyroulla Odysseos

Background: Although the dynamic response of rigid block-like structures standing free on a rigid foundation has been extensively studied to date, only a limited number of studies have focused on the dynamics of such systems when seismically isolated. Objective: This paper presents a comprehensive investigation on the dynamic response of base-isolated rigid blocks subjected to pulse-type base excitation, with the aim of identifying potential trends in the response and stability of the system. Method: The model adopted in this study consists of a rectangular-prismatic rigid block standing free on a seismically-isolated base, which, on the assumption of sufficiently-large friction, can be set into rocking on top of the moving base under dynamic excitation. The study examines in depth the motion of the block/base system with a large-displacement formulation that combines the nonlinear equations of motion with a rigorous model governing impact. Two isolation-system models are utilized in the analysis, a linear viscoelastic model and a bilinear hysteretic model. Results: An extensive numerical investigation was performed to calculate the rocking response of the block under simple acceleration pulses and recorded pulse-type earthquake motions of various amplitudes and frequency content. Response-regime spectra for non-isolated and isolated blocks of varying geometric characteristics have been constructed to evaluate the system performance with respect to the rocking initiation and overturning of the block. Conclusion: The study showed that, regardless of block size and excitation period, seismic isolation increases the acceleration required to initiate rocking, a benefit that increases as the isolation period increases. In regard to the stability of the rocking block, the use of isolation yields a better system performance for smaller-sized blocks both for short- and mid-period excitations, provided that the isolation system is suitably designed. On the contrary, for long-period pulses, the use of isolation is practically not beneficial in improving the stability of the rocking block, irrespective of its size.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 549-556
Author(s):  
Yajun Luo ◽  
Linwei Ji ◽  
Yahong Zhang ◽  
Minglong Xu ◽  
Xinong Zhang

The present work proposed an hourglass-type electromagnetic isolator with negative resistance (NR) shunt circuit to achieve the effective suppression of the micro-amplitude vibration response in various advanced instruments and equipment. By innovatively design of combining the displacement amplifier and the NR electromagnetic shunt circuit, the current new type of vibration isolator not only can effectively solve the problem of micro-amplitude vibration control, but also has significant electromechanical coupling effect, to obtain excellent vibration isolation performance. The design of the isolator and motion relationship is presented firstly. The electromechanical coupling dynamic model of the isolator is also given. Moreover, the optimal design of the NR electromagnetic shunt circuit and the stability analysis of the vibration isolation system are carried out. Finally, the simulation results about the transfer function and vibration responses demonstrated that the isolator has a significant isolation performance.


1998 ◽  
Author(s):  
R. Hampton ◽  
Nagendra Subba Rao ◽  
Young Kim ◽  
William Wagar ◽  
Allen Karchmer

Author(s):  
Satoshi Fujita ◽  
Keisuke Minagawa ◽  
Mitsuru Miyazaki ◽  
Go Tanaka ◽  
Toshio Omi ◽  
...  

This paper describes three-dimensional isolation performance of seismic isolation system using air bearings. Long period seismic waves having predominant period of from a few seconds to a few ten seconds have recently been observed in various earthquakes. Also resonances of high-rise buildings and sloshing of petroleum tanks in consequence of long period seismic waves have been reported. Therefore the isolation systems having very long natural period or no natural period are required. In a previous paper [1], we proposed an isolation system having no natural period by using air bearings. Additionally we have already reported an introduction of the system, and have investigated horizontal motion during earthquake in the previous paper. It was confirmed by horizontal vibration experiment and simulation in the previous paper that the proposed system had good performance of isolation. However vertical motion should be investigated, because vertical motion varies horizontal frictional force. Therefore this paper describes investigation regarding vertical motion of the proposed system by experiment. At first, a vertical excitation test of the system is carried out so as to investigate vertical dynamic property. Then a three-dimensional vibration test using seismic waves is carried out so as to investigate performance of isolation against three-dimensional seismic waves.


2021 ◽  
pp. 107754632110005
Author(s):  
Yonglei Zhang ◽  
Guo Wei ◽  
Hao Wen ◽  
Dongping Jin ◽  
Haiyan Hu

The vibration isolation system using a pair of oblique springs or a spring-rod mechanism as a negative stiffness mechanism exhibits a high-static low-dynamic stiffness characteristic and a nonlinear jump phenomenon when the system damping is light and the excitation amplitude is large. It is possible to remove the jump via adjusting the end trajectories of the above springs or rods. To realize this idea, the article presents a vibration isolation system with a cam–roller–spring–rod mechanism and gives the detailed numerical and experimental studies on the effects of the above mechanism on the vibration isolation performance. The comparative studies demonstrate that the vibration isolation system proposed works well and outperforms some other vibration isolation systems.


Sign in / Sign up

Export Citation Format

Share Document