Optimal Generation of Multivariate Seismic Intensity Maps Using Hazard Quantization

Author(s):  
Liyang Ma ◽  
Daniel Conus ◽  
Paolo Bocchini
Keyword(s):  
2013 ◽  
Vol 671-674 ◽  
pp. 1399-1402
Author(s):  
Ying Sun ◽  
Jian Gang Sun ◽  
Li Fu Cui

To study the impact of floating roof on seismic response of vertical storage tank structure system subjected to seismic excitation, select 150000m3 storage tanks as research object, and the finite element analysis model of storage tanks with and without floating roof were established respectively. The seismic response of these two types of structure in different site conditions and seismic intensity were calculated and the numerical solutions were compared. The results show that floating roof has little impact on base shear and base moment in different site conditions and seismic intensity. Floating roof can effectively reduce the sloshing wave height. The influence of floating roof on dynamic fluid pressure decreases with the increase of seismic intensity, which is less affected by ground conditions.


2016 ◽  
Vol 32 (2) ◽  
pp. 861-879 ◽  
Author(s):  
Hossein Agha Beigi ◽  
Constantin Christopoulos ◽  
Timothy J. Sullivan ◽  
Gian Michele Calvi

Recently, the gapped-inclined brace system (GIB) has been developed as an effective retrofitting solution for soft-story buildings. This paper presents a cost-benefit study of a building retrofitted using the GIB system. A six-story, reinforced concrete (RC) frame with an open story at the ground level and masonry infills on all other floors is studied. To investigate the effectiveness of alternate retrofit configurations, different scenarios of GIB systems are numerically analyzed, expected repair costs for various levels of seismic intensity are computed, and cost benefit values are compared to each other and to those obtained when the building is strengthened and stiffened at the ground floor using conventional methods. Results show that GIB retrofit solutions are likely to represent significant cost benefits compared to traditional retrofit solutions. The results also indicate that GIBs do not need to be positioned at all column locations of the soft story, which could be beneficial in reducing the overall retrofit cost and improving architectural functionality of the retrofitted structure.


2021 ◽  
Vol 11 (11) ◽  
pp. 4898
Author(s):  
Jin-Seon Kim ◽  
Ju-Seong Jung ◽  
Dong-Keun Jung ◽  
Eui-Yong Kim ◽  
Kang-Seok Lee

The present study proposes a new seismic retrofitting method using a concrete-filled tube modular frame (CFT-MF) system, a novel technique to overcome and improve the limitations of existing seismic strengthening methods. This CFT-MF seismic retrofitting method makes the most of the advantages of both concrete and steel pipes, thereby significantly improving constructability and increasing integration between the existing structure and the reinforcement joints. This method falls into the category of typical seismic retrofitting methods that focus on increasing strength, in which the required amount of seismic reinforcement can be easily estimated. Therefore, the method provides an easy solution to improving the strength of existing reinforced concrete (RC) structures with non-seismic details that are prone to shear failure. In the present study, a full-size two-story test frame modeled from existing domestic RC structures with non-seismic details was subjected to pseudo-dynamic testing. As a result, the effect of the CFT-MF system, when applied to existing RC structures, was examined and verified, especially as to its seismic retrofitting performance, i.e., restoring force characteristics, stiffness reinforcement, and seismic response control. In addition, based on the pseudo-dynamic testing results, a restoring force characteristics model was proposed to implement non-linear dynamic analysis of a structure retrofitted with the CFT-MF system (i.e., the test frame). Finally, based on the proposed restoring force characteristics, non-linear dynamic analysis was conducted, and the results were compared with those obtained by the pseudo-dynamic tests. The results showed that the RC frame (building) with no retrofitting measures applied underwent shear failure at a seismic intensity of 200 cm/s2, the threshold applied in seismic design in Korea. In contrast, in the frame (building) retrofitted with the CFT-MF system, only minor earthquake damage was observed, and even when the maximum seismic intensity (300 cm/s2) that may occur in Korean was applied, small-scale damage was observed. These results confirmed the validity of the seismic retrofitting method based on the CFT-MF system developed in the present study. The non-linear dynamic analysis and the pseudo-dynamic test showed similar results, with an average deviation of 10% or less in seismic response load and displacement.


2015 ◽  
Vol 724 ◽  
pp. 353-357
Author(s):  
Jian Zhu ◽  
Ping Tan ◽  
Pei Ju Chang

This study focus on derivation of such vulnerability curves using Fiber Reinforced Polymers technologies retrofitted conventional RC industrial frames with masonry infill wall. A set of stochastic earthquake waves which compatible with the response spectrum of China seismic code are created. Dynamic time history analysis is used to compute the random sample of structures. Stochastic damage scatter diagrams based different seismic intensity index are obtained. Seismic vulnerability of FRP-reinforced RC industrial frames is lower than unreinforced frames obviously, and seismic capability of frames using FRP technologies is enhanced especially under major earthquake.


Sign in / Sign up

Export Citation Format

Share Document