Temporal Integration and Contrast Sensitivity in Foveal and Peripheral Vision

Perception ◽  
1984 ◽  
Vol 13 (6) ◽  
pp. 665-674 ◽  
Author(s):  
Jyrki Rovamo ◽  
Lea Leinonen ◽  
Pentti Laurinen ◽  
Veijo Virsu

Spatial contrast sensitivity functions and temporal integration functions for gratings with dark surrounds were measured at various eccentricities in photopic vision. Contrast sensitivity decreased with increasing eccentricity at all exposure durations and spatial frequencies tested. The decrease was faster at high than at low spatial frequencies, but similar at different exposure durations. When cortically similar stimulus conditions were produced at different eccentricities by M-scaling, contrast sensitivity became independent of visual field location at all exposure durations tested. The results support the view that in photopic vision spatiotemporal information processing is qualitatively similar across the visual field, and that quantitative differences result from retinotopical differences in ganglion cell sampling. For gratings of constant retinal area temporal integration (improvement of contrast sensitivity with increasing exposure duration) was more extensive at high than at low retinal spatial frequencies but independent of cortical spatial frequency and eccentricity. For M-scaled gratings temporal integration was more extensive at high than at low cortical spatial frequencies but independent of retinal spatial frequency and eccentricity. The results suggest that the primary determinant of temporal integration is not spatial frequency but grating value that is calculated as AF2 square cycles (cycle2), where A is grating area and F spatial frequency.


2005 ◽  
Vol 8 (2) ◽  
pp. 113-118
Author(s):  
Miguel A. García-Pérez

Visual functioning at various retinal illuminance levels is usually measured either by determining grating acuity as a function of light level or by determining how sensitivity to sine-wave gratings changes with retinal illuminance. The former line of research has shown that grating acuity follows a two-branch relationship with retinal illuminance, with the point of discontinuity occurring at the transition from scotopic to photopic vision. Results of the latter line of research have summarily been described as a transition from the DeVries-Rose law to Weber's law, according to which log sensitivity increases linearly with log illuminance with a slope of 0.5 over a range of low illuminances (the DeVries-Rose range) and then levels off and does not increase with further increases of illuminance (the Weber range). This paper aims at determining the compatibility of the results of these two lines of research. We consider empirical constraints from data bearing on the shape of the surface describing contrast sensitivity to sine-wave gratings as a function of spatial frequency and illuminance simultaneously, in order to determine whether they are consistent with a summary description in terms of DeVries-Rose and Weber's laws. Our analysis indicates that, with sine-wave gratings, the DeVries-Rose law can only hold empirically at low spatial frequencies.



Perception ◽  
1996 ◽  
Vol 25 (5) ◽  
pp. 523-530 ◽  
Author(s):  
Jonathan S Pointer

Analysis of recently published human contrast-sensitivity data obtained along the cardinal and major oblique visual-field meridians of a single subject has demonstrated a consistently greater sensitivity at a given eccentricity to horizontally oriented as compared with obliquely oriented gratings. This difference was evident not only at foveal but also at several eccentric loci over a range of low to medium spatial frequencies. This observation is to be distinguished in extrafoveal fixation from the well-documented oblique effect, which describes the variation in sensitivity with orientation at a single visual-field locus. With periodic stimuli which were well localised in space and frequency, and had comparable spatial-summation properties, a spatial-frequency dependency of what could be termed the global oblique effect could be demonstrated along isoeccentric contours centred on the fovea (eccentricity 0 deg) out to an eccentricity of at least 40 deg.



2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Zhen Ren ◽  
Jiawei Zhou ◽  
Zhimo Yao ◽  
Zhengchun Wang ◽  
Nini Yuan ◽  
...  

Abstract It is well known that, in humans, contrast sensitivity training at high spatial frequency (SF) not only leads to contrast sensitivity improvement, but also results in an improvement in visual acuity as assessed with gratings (direct effect) or letters (transfer effect). However, the underlying neural mechanisms of this high spatial frequency training improvement remain to be elucidated. In the present study, we examined four properties of neurons in primary visual cortex (area 17) of adult cats that exhibited significantly improved acuity after contrast sensitivity training with a high spatial frequency grating and those of untrained control cats. We found no difference in neuronal contrast sensitivity or tuning width (Width) between the trained and untrained cats. However, the trained cats showed a displacement of the cells’ optimal spatial frequency (OSF) to higher spatial frequencies as well as a larger neuronal signal-to-noise ratio (SNR). Furthermore, both the neuronal differences in OSF and SNR were significantly correlated with the improvement of acuity measured behaviorally. These results suggest that striate neurons might mediate the perceptual learning-induced improvement for high spatial frequency stimuli by an alteration in their spatial frequency representation and by an increased SNR.



Perception ◽  
1997 ◽  
Vol 26 (1_suppl) ◽  
pp. 194-194
Author(s):  
J Jankauskiene ◽  
R Lukauskiene ◽  
B Mickiene

Thyroid optic neuropathy is one of the most troubling complications of endocrine ophthalmopathies. It is related to the degree of extraocular muscle swelling in the apex of the orbit. The purpose of this study was to investigate contrast sensitivity and visual-field thresholds in patients with thyroid optic neuropathy. We examined twenty-two patients aged 29 – 63 years (mean 45.3 years). The control group consisted of fifteen healthy persons of similar age. Contrast sensitivity was measured by means of Volkov's charts (sinusoidal gratings) at eight spatial frequencies from 17.5 to 0.46 cycles deg−1. The visual field was investigated with a static automatic perimeter (Allgan Humphrey Field Analyzer) by means of the central 30-2 threshold test. All patients underwent a complete ophthalmological examination including best corrected Snellen visual acuity, fundus copy, and proptosis measurement with the Hertel exophthalmometer. The mean proptosis of patients was 19.4 mm. Fifteen of the patients had decreased visual acuity. Contrast sensitivity at low spatial frequencies was significantly reduced in the patients. It was established that a reduction of visual-field threshold accompanies the decrease of visual acuity. Our results show that contrast sensitivity and visual-field threshold testing are very sensitive at detecting early optic neuropathy and may be a useful means of following patients after treatment.



Perception ◽  
1997 ◽  
Vol 26 (1_suppl) ◽  
pp. 200-200
Author(s):  
M I Kankaanpää ◽  
J Rovamo ◽  
H T Kukkonen ◽  
J Hallikainen

Contrast sensitivity functions for achromatic and chromatic gratings tend to be band-pass and low-pass in shape, respectively. Our aim was to test whether spatial integration contributes to the shape difference found at low spatial frequencies. We measured binocular chromatic contrast sensitivity as a function of grating area for objectively equiluminous red - green and blue - yellow chromatic gratings. Chromatic contrast refers to the Michelson contrast of either of the two chromatic component gratings presented in counterphase against the combined background. Grating area ( A) varied from 1 to 256 square cycles ( Af2) at spatial frequencies ( f) of 0.125 – 4.0 cycles deg−1. We used only horizontal gratings at low and medium spatial frequencies to minimise the transverse and longitudinal chromatic aberrations due to ocular optics. At all spatial frequencies studied, chromatic contrast sensitivity increased with grating area. Ac was found to be constant at low spatial frequencies (0.125 – 0.5 cycles deg−1) but decreased in inverse proportion to increasing spatial frequency at 1 – 4 cycles deg−1. Thus, spatial integration depends similarly on spatial frequency for achromatic (Luntinen et al, 1995 Vision Research35 2339 – 2346) and chromatic gratings, and differences in spatial integration do not contribute to the shape difference of the respective contrast sensitivity functions.



2002 ◽  
Vol 14 (2) ◽  
pp. 291-297 ◽  
Author(s):  
Matia Okubo ◽  
Chikashi Michimata

Right-handed participants performed the categorical and coordinate spatial relation judgments on stimuli presented to either the left visual field—right hemisphere (LVF-RH) or the right visual field—left hemisphere (RVF-LH). The stimulus patterns were formulated either by bright dots or by contrast-balanced dots. When the stimuli were bright, an RVF-LH advantage was observed for the categorical task, whereas an LVF-RH advantage was observed for the coordinate task. When the stimuli were contrast balanced, the RVF-LH advantage was observed for the categorical task, but the LVF-RH advantage was eliminated for the coordinate task. Because the contrast-balanced dots are largely devoid of low spatial frequency content, these results suggest that processing of low spatial frequency is responsible for the right hemisphere advantage for the coordinate spatial processing.



2021 ◽  
Vol 2 (2) ◽  
pp. 63-70
Author(s):  
Abolfazl Tahkor ◽  
Javad Heravian Shandiz ◽  
Abbas Azimi Khorasani ◽  
Alireza Ansari Moghadam

Background: Measuring contrast sensitivity (CS) allows a better understanding of the visual performance of the human eye. This study aimed to examine the correlation and agreement between the results of two sinewave grating-based CS measurement methods, Metrovision and CSV-1000, in normal eyes. Methods: This cross-sectional, comparative study was performed between December 2018 and April 2019, at an optometry clinic. Subjects underwent comprehensive ocular examinations, which included pupil reflexes, subjective refraction, external eye examinations, smooth pursuit eye movement assessment, the cover–uncover test, and detailed slit-lamp examination of the anterior and posterior segments. Metrovision and CSV-1000 were employed to assess CS under photopic conditions. The correlation and agreement of the results of the two tests were evaluated. Results: CS was measured for 104 normal eyes for 3, 6, 12, and 18 cycles per degree (cpd) spatial frequencies (participants’ mean age ± standard deviation: 37.3 ± 26.4 years). The CSV-1000 measurements were significantly higher for the 3 and 6 cpd spatial frequencies (both P = 0.01); however, at higher spatial frequencies, CS scores were similar. The highest and lowest differences between the two tests were recorded for the 3 cpd spatial frequency and 18 cpd spatial frequency, respectively. Except for the 3 cpd spatial frequency, in both eyes, the findings correlated significantly between the CSV-1000 and Metrovision (P < 0.05). The narrowest and widest limits of agreement between the two tests were found for the 12 and 3 cpd spatial frequencies, respectively. Conclusions: The CSV-1000 method estimated CS higher than the Metrovision method, mostly at lower spatial frequencies. Furthermore, the agreement between the two methods was greater at higher spatial frequencies than at lower frequencies. This should be kept in mind when using the two methods interchangeably in visual screening.



2004 ◽  
Vol 16 (9) ◽  
pp. 1576-1582 ◽  
Author(s):  
Matia Okubo ◽  
Chikashi Michimata

Right-handed participants performed categorical and coordinate spatial relation tasks on stimuli presented either to the left visual field-right hemisphere (LVF-RH) or to the right visual field-left hemisphere (RVF-LH). The stimuli were either unfiltered or low-pass filtered (i.e., devoid of high spatial frequency content). Consistent with previous studies, the unfiltered condition produced a significant RVF-LH advantage for the categorical task and an LVF-RH advantage for the coordinate task. Low-pass filtering eliminated this Task × Visual Field interaction; thus, the RVF-LH advantage disappeared for the categorical task. The present results suggest that processing of high spatial frequency contributes to the left hemispheric advantage for categorical spatial processing.



Perception ◽  
1997 ◽  
Vol 26 (1_suppl) ◽  
pp. 214-214 ◽  
Author(s):  
S A Koskin ◽  
V F Danilichev ◽  
Y E Shelepin

We studied the contrast sensitivity functions (CSFs) in patients with different eye and brain diseases using a computerised sinusoidal grating test with a wide range of frequencies (0.4 – 19.0 cycles deg−1), the Pelli - Robson chart and a new chart with frequency-filtered Snellen optotypes. The patients had different CSF curves with a decrease of contrast sensitivity in the low, middle, or high frequencies depending on their main disease (refraction anomalies, cataract, glaucoma, neuritis of optic nerve, brain tumours, etc). Analysis showed that optotypes in the Pelli - Robson chart have a wide-range spatial-frequency spectrum, and optotype recognition is determined not only by low spatial frequencies. We find that the recognition of standard Sloan's optotypes is determined mostly by sensitivity in the range of 9.4 – 14.0 cycles deg−1. At the same time we measured contrast sensitivity using the new filtered Snellen optotypes. Our calculations support our earlier suggestions that the new filtered optotypes have a narrow-band spatial-frequency spectrum, thus enabling selective measurement of contrast sensitivity in each narrow frequency band.



Perception ◽  
1997 ◽  
Vol 26 (1_suppl) ◽  
pp. 48-48
Author(s):  
B Wink ◽  
J P Harris

It has been suggested that the Parkinsonian visual system is like the normal visual system, but is inappropriately dark-adapted (Beaumont et al, 1987 Clinical Vision Sciences2 123 – 129). Thus it is of interest to ask to what extent dark adaptation of normal subjects produces visual changes like those of Parkinson's disease (PD). One such change is the reduction in apparent contrast of medium and high spatial frequencies in peripheral vision in the illness (Harris et al, 1992 Brain115 1447 – 1457). Normal subjects judged whether the contrast of a peripherally viewed grating was higher or lower than that of a foveally viewed grating, and a staircase technique was used to estimate the point of subjective equality. Judgements were made at four spatial frequencies (0.5 to 4.0 cycles deg−1) and four contrasts (8.0% to 64%). The display, the mean luminance of which was 26 cd m−2, was viewed through a 1.5 lu nd filter in the relatively dark-adapted condition. The ANOVA showed an interaction between dark adaptation and the spatial frequency of the gratings. Dark adaptation reduces the apparent contrast of high-spatial-frequency gratings, an effect which is greater at lower contrasts. This mimics the effect found with PD sufferers, and suggests that dark adaptation may provide a useful model of the PD visual system. In a second experiment, the effect of dark adaptation on the relationship between apparent spatial frequency in the fovea and periphery was investigated. The experiment was similar to the first, except that judgements were made about the apparent spatial frequency, rather than the contrast, of the peripheral grating. ANOVA showed no differential effect of dark adaptation on the apparent spatial frequency of the peripheral grating. This suggests that the observed reduction in apparent contrast of the peripheral gratings in dark-adapted normals and Parkinson's sufferers may reflect relative changes in contrast gain, rather than relative changes in the spatial organisation of receptive fields.



Sign in / Sign up

Export Citation Format

Share Document