scholarly journals An ammonite trapped in Burmese amber

2019 ◽  
Vol 116 (23) ◽  
pp. 11345-11350 ◽  
Author(s):  
Tingting Yu ◽  
Richard Kelly ◽  
Lin Mu ◽  
Andrew Ross ◽  
Jim Kennedy ◽  
...  

Amber is fossilized tree resin, and inclusions usually comprise terrestrial and, rarely, aquatic organisms. Marine fossils are extremely rare in Cretaceous and Cenozoic ambers. Here, we report a record of an ammonite with marine gastropods, intertidal isopods, and diverse terrestrial arthropods as syninclusions in mid-Cretaceous Burmese amber. We used X-ray–microcomputed tomography (CT) to obtain high-resolution 3D images of the ammonite, including its sutures, which are diagnostically important for ammonites. The ammonite is a juvenile Puzosia (Bhimaites) and provides supporting evidence for a Late Albian–Early Cenomanian age of the amber. There is a diverse assemblage (at least 40 individuals) of arthropods in this amber sample from both terrestrial and marine habitats, including Isopoda, Acari (mites), Araneae (spiders), Diplopoda (millipedes), and representatives of the insect orders Blattodea (cockroaches), Coleoptera (beetles), Diptera (true flies), and Hymenoptera (wasps). The incomplete preservation and lack of soft body of the ammonite and marine gastropods suggest that they were dead and underwent abrasion on the seashore before entombment. It is most likely that the resin fell to the beach from coastal trees, picking up terrestrial arthropods and beach shells and, exceptionally, surviving the high-energy beach environment to be preserved as amber. Our findings not only represent a record of an ammonite in amber but also provide insights into the taphonomy of amber and the paleoecology of Cretaceous amber forests.

Author(s):  
E. B. Steel

High Purity Germanium (HPGe) x-ray detectors are now commercially available for the analytical electron microscope (AEM). The detectors have superior efficiency at high x-ray energies and superior resolution compared to traditional lithium-drifted silicon [Si(Li)] detectors. However, just as for the Si(Li), the use of the HPGe detectors requires the determination of sensitivity factors for the quantitative chemical analysis of specimens in the AEM. Detector performance, including incomplete charge, resolution, and durability has been compared to a first generation detector. Sensitivity factors for many elements with atomic numbers 10 through 92 have been determined at 100, 200, and 300 keV. This data is compared to Si(Li) detector sensitivity factors.The overall sensitivity and utility of high energy K-lines are reviewed and discussed. Many instruments have one or more high energy K-line backgrounds that will affect specific analytes. One detector-instrument-specimen holder combination had a consistent Pb K-line background while another had a W K-line background.


Author(s):  
James F. Mancuso ◽  
William B. Maxwell ◽  
Russell E. Camp ◽  
Mark H. Ellisman

The imaging requirements for 1000 line CCD camera systems include resolution, sensitivity, and field of view. In electronic camera systems these characteristics are determined primarily by the performance of the electro-optic interface. This component converts the electron image into a light image which is ultimately received by a camera sensor.Light production in the interface occurs when high energy electrons strike a phosphor or scintillator. Resolution is limited by electron scattering and absorption. For a constant resolution, more energy deposition occurs in denser phosphors (Figure 1). In this respect, high density x-ray phosphors such as Gd2O2S are better than ZnS based cathode ray tube phosphors. Scintillating fiber optics can be used instead of a discrete phosphor layer. The resolution of scintillating fiber optics that are used in x-ray imaging exceed 20 1p/mm and can be made very large. An example of a digital TEM image using a scintillating fiber optic plate is shown in Figure 2.


Author(s):  
A.J. Tousimis

An integral and of prime importance of any microtopography and microanalysis instrument system is its electron, x-ray and ion detector(s). The resolution and sensitivity of the electron microscope (TEM, SEM, STEM) and microanalyzers (SIMS and electron probe x-ray microanalyzers) are closely related to those of the sensing and recording devices incorporated with them.Table I lists characteristic sensitivities, minimum surface area and depth analyzed by various methods. Smaller ion, electron and x-ray beam diameters than those listed, are possible with currently available electromagnetic or electrostatic columns. Therefore, improvements in sensitivity and spatial/depth resolution of microanalysis will follow that of the detectors. In most of these methods, the sample surface is subjected to a stationary, line or raster scanning photon, electron or ion beam. The resultant radiation: photons (low energy) or high energy (x-rays), electrons and ions are detected and analyzed.


2013 ◽  
Vol 58 (2) ◽  
pp. 619-624 ◽  
Author(s):  
M. Szafarska ◽  
J. Iwaszko ◽  
K. Kudła ◽  
I. Łegowik

The main aim of the study was the evaluation of magnesium alloy surface treatment effectiveness using high-energy heat sources, i.e. a Yb-YAG Disk Laser and the GTAW method. The AZ91 and AM60 commercial magnesium alloys were subject to surface layer modification. Because of the physicochemical properties of the materials studied in case of the GTAW method, it was necessary to provide the welding stand with additional equipment. A novel two-torch set with torches operating in tandem was developed within the experiment. The effectiveness of specimen remelting using a laser and the GTAW method was verified based on macro- and microscopic examinations as well as in X-ray phase analysis and hardness measurements. In addition, the remelting parameters were optimised. The proposed treatment methodology enabled the achieving of the intended result and effective modification of a magnesium alloy surface layer.


AIAA Journal ◽  
2001 ◽  
Vol 39 ◽  
pp. 919-923
Author(s):  
U. Lienert ◽  
H. F. Poulsen ◽  
A. Kvick

2020 ◽  
Vol 38 (4A) ◽  
pp. 491-500
Author(s):  
Abeer F. Al-Attar ◽  
Saad B. H. Farid ◽  
Fadhil A. Hashim

In this work, Yttria (Y2O3) was successfully doped into tetragonal 3mol% yttria stabilized Zirconia (3YSZ) by high energy-mechanical milling to synthesize 8mol% yttria stabilized Zirconia (8YSZ) used as an electrolyte for high temperature solid oxide fuel cells (HT-SOFC). This work aims to evaluate the densification and ionic conductivity of the sintered electrolytes at 1650°C. The bulk density was measured according to ASTM C373-17. The powder morphology and the microstructure of the sintered electrolytes were analyzed via Field Emission Scanning Electron Microscopy (FESEM). The chemical analysis was obtained with Energy-dispersive X-ray spectroscopy (EDS). Also, X-ray diffraction (XRD) was used to obtain structural information of the starting materials and the sintered electrolytes. The ionic conductivity was obtained through electrochemical impedance spectroscopy (EIS) in the air as a function of temperatures at a frequency range of 100(mHz)-100(kHz). It is found that the 3YSZ has a higher density than the 8YSZ. The impedance analysis showed that the ionic conductivity of the prepared 8YSZ at 800°C is0.906 (S.cm) and it was 0.214(S.cm) of the 3YSZ. Besides, 8YSZ has a lower activation energy 0.774(eV) than that of the 3YSZ 0.901(eV). Thus, the prepared 8YSZ can be nominated as an electrolyte for the HT-SOFC.


2016 ◽  
Author(s):  
Antonio Lanzirotti ◽  
◽  
Stephen R. Sutton ◽  
Matt Newville ◽  
Jeffrey P. Fitts ◽  
...  

2020 ◽  
Vol 26 ◽  
pp. 58-64 ◽  
Author(s):  
S. Xiao ◽  
S.L. Xiong ◽  
C.Z. Liu ◽  
X.B. Li ◽  
S.N. Zhang ◽  
...  
Keyword(s):  

Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2207
Author(s):  
Żaneta Garczyk ◽  
Zbigniew Jaegermann ◽  
Piotr Duda ◽  
Andrzej S. Swinarew ◽  
Sebastian Stach

The main aim of this study was to analyze microtomographic data to determine the geometric dimensions of a ceramic porous material’s internal structure. Samples of a porous corundum biomaterial were the research material. The samples were prepared by chemical foaming and were measured using an X-ray scanner. In the next stage, 3D images of the samples were generated and analyzed using Thermo Scientific Avizo software. The analysis enabled the isolation of individual pores. Then, the parameters characterizing the pore geometry and the porosity of the samples were calculated. The last part of the research consisted of verifying the developed method by comparing the obtained results with the parameters obtained from the microscopic examinations of the biomaterial. The comparison of the results confirmed the correctness of the developed method. The developed methodology can be used to analyze biomaterial samples to assess the geometric dimensions of biomaterial pores.


Sign in / Sign up

Export Citation Format

Share Document