The association of galectin-3 level with ventricular arrhythmias and left ventricular strain in heart failure patients with implantable cardioverter defibrillator

2021 ◽  
pp. 1-7
Author(s):  
Tayyar Akbulut ◽  
Faysal Saylik ◽  
Abdulcabbar Sipal
Author(s):  

Dilated cardiomyopathy (DCM) is a disease characterised as left ventricular (LV) or biventricular dilatation with impaired systolic function. Regardless of underlying cause patients with DCM have a propensity to ventricular arrhythmias and sudden cardiac death. Implantable Cardioverter Defibrillator (ICD) implantation for these patients results in significant reduction of sudden cardiac death [1-3]. ICD devices may be limited by right ventricle (RV) sensing dysfunction with low RV sensing amplitude. We present a clinical case of patient with DCM, implanted ICD and low R wave sensing on RV lead.


2021 ◽  
Vol 10 (4) ◽  
Author(s):  
Andrea Demarchi ◽  
Stefano Cornara ◽  
Antonio Sanzo ◽  
Simone Savastano ◽  
Barbara Petracci ◽  
...  

Background When implantable cardioverter defibrillator (ICD) battery is depleted most patients undergo generator replacement (GR) even in the absence of persistent ICD indication. The aim of this study was to assess the incidence of ventricular arrhythmias and the overall prognosis of patients with and without persistent ICD indication undergoing GR. Predictors of 1‐year mortality were also analyzed. Methods and Results Patients with structural heart disease implanted with primary prevention ICD undergoing GR were included. Patients were stratified based on the presence/absence of persistent ICD indication (left ventricular ejection fraction ≤35% at the time of GR and/or history of appropriate ICD therapies during the first generator's life). The study included 371 patients (82% male, 40% with ischemic heart disease). One third of patients (n=121) no longer met ICD indication at the time of GR. During a median follow‐up of 34 months after GR patients without persistent ICD indication showed a significantly lower incidence of appropriate ICD shocks (1.9% versus 16.2%, P <0.001) and ICD therapies. 1‐year mortality was also significantly lower in patients without persistent ICD indication (1% versus 8.3%, P =0.009). At multivariable analysis permanent atrial fibrillation, chronic advanced renal impairment, age >80, and persistent ICD indication were found to be significant predictors of 1‐year mortality. Conclusions Patients without persistent ICD indication at the time of GR show a low incidence of appropriate ICD therapies after GR. Persistent ICD indication, atrial fibrillation, advanced chronic renal disease, and age >80 are significant predictors of 1‐year mortality. Our findings enlighten the need of performing a comprehensive clinical reevaluation of ICD patients at the time of GR.


2021 ◽  
Vol 11 (1) ◽  
pp. 121
Author(s):  
Marco Canepa ◽  
Pietro Palmisano ◽  
Gabriele Dell’Era ◽  
Matteo Ziacchi ◽  
Ernesto Ammendola ◽  
...  

The role of prognostic risk scores in predicting the competing risk of non-sudden death in heart failure patients with reduced ejection fraction (HFrEF) receiving an implantable cardioverter-defibrillator (ICD) is unclear. To this goal, we evaluated the accuracy and usefulness of the Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score. The present analysis included 1089 HFrEF ICD recipients enrolled in the OBSERVO-ICD registry (NCT02735811). During a median follow-up of 36 months (1st–3rd IQR 25–48 months), 193 patients (17.7%) experienced at least one appropriate ICD therapy, and 133 patients died (12.2%) without experiencing any ICD therapy. The frequency of patients receiving ICD therapies was stable around 17–19% across increasing tertiles of 3-year MAGGIC probability of death, whereas non-sudden mortality increased (6.4% to 9.8% to 20.8%, p < 0.0001). Accuracy of MAGGIC score was 0.60 (95% CI, 0.56–0.64) for the overall outcome, 0.53 (95% CI, 0.49–0.57) for ICD therapies and 0.65 (95% CI, 0.60–0.70) for non-sudden death. In patients with higher 3-year MAGGIC probability of death, the increase in the competing risk of non-sudden death during follow-up was greater than that of receiving an appropriate ICD therapy. Results were unaffected when analysis was limited to ICD shocks only. The MAGGIC risk score proved accurate and useful in predicting the competing risk of non-sudden death in HFrEF ICD recipients. Estimation of mortality risk should be taken into greater consideration at the time of ICD implantation.


Sign in / Sign up

Export Citation Format

Share Document