Dehumidification of Moist Air with Simultaneous Removal of Selected Indoor Pollutants by Triethylene Glycol Solutions in a Packed-Bed Absorber

1995 ◽  
Vol 30 (7-9) ◽  
pp. 1807-1832 ◽  
Author(s):  
Tsair-Wang Chung ◽  
Tushar K. Ghosh ◽  
Anthony L. Hines ◽  
Davor Novosel
2021 ◽  
Author(s):  
Panagiota Mendrinou ◽  
Artin Hatzikioseyian ◽  
Pavlina Kousi ◽  
Paschalis Oustadakis ◽  
Petros Tsakiridis ◽  
...  

Abstract Α pilot scale packed-bed biofilm reactor was set up and monitored for the treatment of wastewater originating from the hydrometallurgical recovery of metals from printed circuit boards (PCBs). The wastewater is characterized by: (a) low pH, (b) residual soluble metal species and (c) elevated concentrations of nitrate and chloride originating from the use of nitric and hydrochloric acid as leaching agents. Such wastewater could be treated in a bioreactor capable for the simultaneous removal of metals and nitrates, through complete denitrification, in presence of elevated chloride concentrations. However, the possible inhibitory effects of metals as well as the metals bioprecipitation should be investigated experimentally. Biological denitrification was studied under extreme conditions in the bioreactor inoculated with Halomonas denitrificans: at (a) pH 3-8; (b) metal content (Cu, Ni, Zn and Fe) at 50 mg/L and 100 mg/L, respectively (c) nitrate concentration 750-5,750 mg/L NO3- and (d) chloride concentration 5%-10% as NaCl. According to the results, denitrification proceeds rapidly through the formation of nitrite as intermediate which is sequentially reduced completely to nitrogen. The presence of metals does not affect the denitrification process. Iron, zinc, copper and nickel are sequestered from the wastewater via bioprecipitation. Both goals, namely metals removal and complete reduction of nitrate in presence of elevated concentrations of chloride, were successfully achieved by the treatment scheme. The proposed simple, robust and low-cost biological treatment unit is advantageous compared to the conventional wastewater treatment, based on metal precipitation via chemical neutralization, where the problem of nitrate removal remains unresolved.


2019 ◽  
Vol 7 (2) ◽  
pp. 90-100
Author(s):  
Jenan Hemeidan ◽  
Ali Abbar

The simultaneous removal of copper and cadmium from a simulated wastewater using rotating tubular packed bed of woven screens electrode was investigated. The effect of weight present of each metal on the removal efficiency and current efficiency was studied. The experiments were carried out at current 1.5 A, rotation speed 450 rpm, pH=2, and total concentration of metals (300 ppm) at different weight percent of each metal. The results showed that the removal efficiency of copper increased from 93.5 % to 99.33% as its weight percent increased from 20% to100%. In a similar fashion, the removal efficiency of cadmium increased from 80% to 90% as its weight percent increased from 20% to100 %. The results confirmed that the removal efficiency of any metals decreased in the presence of other metal. The results established that current efficiency for the simultaneous removal of copper and cadmium decreased with increasing of electrolysis time and Cd percent weight or decreasing of Cu weight percent. Current efficiency is higher at the initial stage of electrolysis and then declined with increasing time for all weight percent of metals.


2006 ◽  
Vol 13 (02n03) ◽  
pp. 279-286 ◽  
Author(s):  
HONDA WU ◽  
TSAIR-WANG CHUNG

In order to study the mass transfer phenomena for water vapor absorbed by triethylene glycol (TEG) solution and to elucidate effect of interfacial disturbance on absorption performance, the interfacial phenomena for water drop instilling on the surface of TEG solution and mass transfer process were observed and operated in this study. Besides liquid and gas flow rates, the interfacial disturbance can also affect the mass transfer performance in the absorption system with continuous liquid phase, and the advanced mass transfer phenomena must be discussed from the interface of matter. Therefore, the surface tensions of desiccant solutions were measured to analyze the disturbed phenomena of water drop instilling on the surface of TEG solution. Since the Marangoni-Index (MI) means the maximum surface tension difference on the surface of liquid layer, the values of MI were calculated and compared with the mass transfer performance of packed-bed absorber. Generally speaking, the interfacial disturbance, resulted from the surface tension difference, would promote the contacting area of gas and liquid phases. The observation of water drop instilling on surface of TEG solution found that the interfacial disturbance existed between water drop and TEG solution, and the interfacial instability was found in the peripheral region of the water drop. On the other hand, the values of MI were increased by the increased TEG concentrations, and it can be deduced that the surface tension effect should be significant in the higher concentration of TEG solution and the interfacial disturbance would be heavier above 95 wt.% TEG solutions. Finally, the absorption performance for 95 and 96 wt.% TEG solutions were much larger than that of 90 and 88.6 wt.% TEG solutions in the operation of packed-bed absorber.


2013 ◽  
Vol 52 (4-6) ◽  
pp. 737-743 ◽  
Author(s):  
Joo-Young Jeong ◽  
Young-Hyun Song ◽  
Jung-Hwan Kim ◽  
Joo-Yang Park

Sign in / Sign up

Export Citation Format

Share Document