scholarly journals Estimation of potential demand reduction by commercial air conditioner control considering outdoor air temperature

2017 ◽  
Vol 7 (1) ◽  
pp. 174-180 ◽  
Author(s):  
Kentaro Takagi ◽  
Hiroshi Asano ◽  
Shigeru Bando
2021 ◽  
Vol 39 (5) ◽  
pp. 1483-1490
Author(s):  
Andriyanto Setyawan ◽  
Susilawati Susilawati ◽  
Tandi Sutandi ◽  
Hafid Najmudin

An experiment has been carried out for examining the performance of an air conditioning unit under constant outdoor wet-bulb temperature and varied dry-bulb temperature. During the experiment, the wet-bulb temperature of the compartment for outdoor unit was maintained at 22℃ and the dry-bulb temperature was varied from 24℃ to 36℃. The increase of outdoor air temperature results in the increase of supply air temperature, discharge temperature, suction temperature, and liquid line temperature. These cause the degradation of the air conditioner performance. An increase of power consumption by 1.4% and decrease of cooling capacity by 0.8% were observed for each 1℃ increase of outdoor air temperature. As a result, the energy efficiency ratio drops by 2% for each 1℃ increase of outdoor air temperature.


2021 ◽  
pp. 1420326X2110321
Author(s):  
Jing Hou ◽  
Yuexia Sun ◽  
Yangrui Song ◽  
Jungsoo Kim ◽  
Thomas Parkinson ◽  
...  

This paper presents results of a longitudinal field study which aims to investigate adaptive comfort behaviours (i.e. turning on air-conditioner, turning on fans and opening windows or doors) in residential buildings. Field measurements were conducted in 43 homes in Tianjin, northern China, from Spring through early Winter in 2016. Occupants' ‘right-here-right-now' thermal perception and adaptive comfort behaviours were collected through online questionnaires delivered to their smartphones. Results indicated that clothing insulation adjustment was the requisite adaptive behaviour to attain thermal comfort. Clothing insulation was more climate-responsive in Tianjin's autumn than in summer. Statistical models were developed to predict the likelihood of various thermally adaptive behaviours with regard to outdoor air temperatures. An outdoor air temperature of 25.2°C was associated with maximum use of windows/doors for comfort ventilation and minimum use of air conditioning (AC). When outdoor air temperature exceeded 32.5°C, 50% of occupants turned on AC for cooling.


2020 ◽  
Vol 61 ◽  
pp. 102200
Author(s):  
Zhongqi Yu ◽  
Shisheng Chen ◽  
Nyuk Hien Wong ◽  
Marcel Ignatius ◽  
Jiyu Deng ◽  
...  

2020 ◽  
Vol 10 (22) ◽  
pp. 8067
Author(s):  
Tomohiro Mashita ◽  
Tetsuya Kanayama ◽  
Photchara Ratsamee

Air conditioners enable a comfortable environment for people in a variety of scenarios. However, in the case of a room with multiple people, the specific comfort for a particular person is highly dependent on their clothes, metabolism, preference, and so on, and the ideal conditions for each person in a room can conflict with each other. An ideal way to resolve these kinds of conflicts is an intelligent air conditioning system that can independently control air temperature and flow at different areas in a room and then produce thermal comfort for multiple users, which we define as the personal preference of air flow and temperature. In this paper, we propose Personal Atmosphere, a machine learning based method to obtain parameters of air conditioners which generate non-uniform distributions of air temperature and flow in a room. In this method, two dimensional air-temperature and -flow distributions in a room are used as input to a machine learning model. These inputs can be considered a summary of each user’s preference. Then the model outputs a parameter set for air conditioners in a given room. We utilized ResNet-50 as the model and generated a data set of air temperature and flow distributions using computational fluid dynamics (CFD) software. We then conducted evaluations with two rooms that have two and four air conditioners under the ceiling. We then confirmed that the estimated parameters of the air conditioners can generate air temperature and flow distributions close to those required in simulation. We also evaluated the performance of a ResNet-50 with fine tuning. This result shows that its learning time is significantly decreased, but performance is also decreased.


2020 ◽  
Vol 15 (3) ◽  
pp. 163-170
Author(s):  
Rajan KC ◽  
Hom Bahadur Rijal ◽  
Masanori Shukuya ◽  
Kazui Yoshida

The energy use in residential dwellings has been increasing due to increasing use of modern electric appliances to make the lifestyle easier, entertaining and better. One of the major purposes of indoor energy use is for improving indoor thermal environment for adjusting thermal comfort. Along with the use of passive means like the use of mechanical devices, the occupants in any dwellings use active means such as the use of natural ventilation, window opening, and clothing adjustment. In fact, the use of active means when the outdoor environment is good enough might be more suitable to improve indoor thermal environment than the use of mechanical air conditioning units, which necessarily require electricity. Therefore, the people in developing countries like Nepal need to understand to what extent the occupants can use active means to manage their own indoor thermal comfort. The use of active means during good outdoor environment might be an effective way to manage increasing energy demand in the future. We have made a field survey on the occupants’ adaptive behaviors for thermal comfort in a Japanese condominium equipped with Home Energy Management System (HEMS). Online questionnaire survey was conducted in a condominium with 356 families from November 2015 to October 2016 to understand the occupants’ behaviors. The number of 17036 votes from 39 families was collected. The indoor air temperature, relative humidity and illuminance were measured at the interval of 2-10 minutes to know indoor thermal environmental conditions. The occupants were found using different active behaviors for thermal comfort adjustments even in rather harsh summer and winter. Around 80% of the occupants surveyed opened windows when the outdoor air temperature was 30⁰C in free running (FR) mode and the clothing insulation was 0.93 clo when the outdoor air temperature was 0⁰C. The result showed that the use of mechanical heating and cooling was not necessarily the first priority to improve indoor thermal environment. Our result along with other results in residential buildings showed that the adaptive behaviors of the occupants are one of the primary ways to adjust indoor thermal comfort. This fact is important in enhancing the energy saving building design.


2014 ◽  
Vol 18 (3) ◽  
pp. 925-934 ◽  
Author(s):  
Meghana Charde ◽  
Sourabh Bhati ◽  
Ayushman Kheterpal ◽  
Rajiv Gupta

Energy efficient building technologies can reduce energy consumption in buildings. In present paper effect of designed static sunshade, brick cavity wall with brick projections and their combined effect on indoor air temperature has been analyzed by constructing three test rooms each of habitable dimensions (3.0 m ? 4.0 m ? 3.0 m) and studying hourly temperatures on typical days for one month in summer and winter each. The three rooms have also been simulated using a software and the results have been compared with the experimental results. Designed static sunshade increased indoor air temperature in winter while proposed brick cavity wall with brick projections lowered it in summer. Combined effect of building elements lowered indoor air temperature in summer and increased it in winter as compared to outdoor air temperature. It is thus useful for energy conservation in buildings in composite climate.


2019 ◽  
Vol 111 ◽  
pp. 06045
Author(s):  
Mizuki Niimura ◽  
U Yanagi

Subterranean temperature at a depth of 10 m is almost equal to the average outdoor air temperature of the same area. Therefore, if a building cooling trench is used as an outdoor air duct, outdoor air can be cooled in summer and warmed in winter. This energy-saving technique is often used in Japan. However, since the relative humidity in a cooling trench is high, microbe numbers tend to increase in summer. The present study sought to characterize the microbiome status in the cooling trench of such an office building in Japan. Specifically, we performed a metagenomic analysis in which we analyzed DNA directly upon collection from the environment, without intervening cultivation. The results showed the presence of bacteria of the genera Pseudomonas, Lactobacillus, Nesterenkonia, Staphylococcus, Deinococcus, Acinetobacter, Enhydorobacter, and Corynebacterium. Bacteria of the genera Nesterenkonia, Deinococcus, Enhydorobacter, and Corynebacterium predominated on the surface of the trench. Notably, bacteria of the genus Nesterenkonia constituted >50% of the organisms on the surface of the downstream end of the cooling trench. Principal coordinate analysis was used to compare bacterial inhabitants of outdoor air, indoor air from 2nd- and 3rdfloor offices, and the region downstream of the cooling trench. The results suggested that the microbiome of air in this cooling trench influenced indoor air within the building.