scholarly journals Comparative thermal performance of static sunshade and brick cavity wall for energy efficient building envelope in composite climate

2014 ◽  
Vol 18 (3) ◽  
pp. 925-934 ◽  
Author(s):  
Meghana Charde ◽  
Sourabh Bhati ◽  
Ayushman Kheterpal ◽  
Rajiv Gupta

Energy efficient building technologies can reduce energy consumption in buildings. In present paper effect of designed static sunshade, brick cavity wall with brick projections and their combined effect on indoor air temperature has been analyzed by constructing three test rooms each of habitable dimensions (3.0 m ? 4.0 m ? 3.0 m) and studying hourly temperatures on typical days for one month in summer and winter each. The three rooms have also been simulated using a software and the results have been compared with the experimental results. Designed static sunshade increased indoor air temperature in winter while proposed brick cavity wall with brick projections lowered it in summer. Combined effect of building elements lowered indoor air temperature in summer and increased it in winter as compared to outdoor air temperature. It is thus useful for energy conservation in buildings in composite climate.

2019 ◽  
Vol 111 ◽  
pp. 06074
Author(s):  
Silviana Brata ◽  
Cristina Tanasa ◽  
Valeriu Stoian ◽  
Dan Stoian ◽  
Daniel Dan ◽  
...  

The significant share of energy consumption of the building sector in the total energy consumption makes it responsible for 36% of CO2 emission in the European Union. In the last decade a key objective of the EU is to improve the energy efficiency and increase the use of renewables in buildings. Ground-to-air heat exchangers can be a solution for reducing primary energy consumption from nonrenewable sources in buildings and contribute to the share of energy from renewable sources. The research in this paper deals with investigations on a ground to air heat exchanger of a pilot energy efficient building, constructed in west side of Romania. The study presents the assessment of the heating and cooling energy potential of the ground-to-air heat exchanger serving the energy efficient building. Three full years of measurements of the air temperature entering the ground-air heat exchanger and the outlet air temperature are available and were used in the study. A comparison is made between the energy potential determined based on temperature measurements and the energy potential based on calculated outlet temperatures using a computational model and conventional climate data for the building location.


2015 ◽  
Vol 14 (7) ◽  
pp. 1487-1494 ◽  
Author(s):  
Marco Arnesano ◽  
Gian Marco Revel ◽  
Filippo Pietroni ◽  
Jurgen Frick ◽  
Manuela Reichert ◽  
...  

Author(s):  
Premkumar Chithaluru ◽  
Rajeev Tiwari ◽  
Kamal Kumar

Background: Energy Efficient wireless routing has been an area of research particularly to mitigate challenges surrounding performance in category of Wireless Networks. Objectives: The Opportunistic Routing (OR) technique was explored in recent times and exhibits benefits over many existing protocols and can significantly reduce energy consumption during data communication with very limited compromise on performance. Methods : Using broadcasting nature of the wireless medium, OR practices to discourse two foremost issues of variable link quality and unpredictable node agility in constrained WSNs. OR has a potential to reduce delay in order to increase the consistency of data delivery in network. Results : Various OR based routing protocols have shown varying performances. In this paper, a detailed conceptual and experimental analysis is carried out on different protocols that uses OR technique for providing more clear and definitive view on performance parameters like Message Success Rate, Packet Delivery Ratio and Energy Consumption.


2020 ◽  
pp. 014459872096921
Author(s):  
Yanru Li ◽  
Enshen Long ◽  
Lili Zhang ◽  
Xiangyu Dong ◽  
Suo Wang

In the Yangtze River zone of China, the heating operation in buildings is mainly part-time and part-space, which could affect the indoor thermal comfort while making the thermal process of building envelope different. This paper proposed to integrate phase change material (PCM) to building walls to increase the indoor thermal comfort and attenuate the temperature fluctuations during intermittent heating. The aim of this study is to investigate the influence of this kind of composite phase change wall (composite-PCW) on the indoor thermal environment and energy consumption of intermittent heating, and further develop an optimization strategy of intermittent heating operation by using EnergyPlus simulation. Results show that the indoor air temperature of the building with the composite-PCW was 2–3°C higher than the building with the reference wall (normal foamed concrete wall) during the heating-off process. Moreover, the indoor air temperature was higher than 18°C and the mean radiation temperature was above 20°C in the first 1 h after stopping heating. Under the optimized operation condition of turning off the heating device 1 h in advance, the heat release process of the composite-PCW to the indoor environment could maintain the indoor thermal environment within the comfortable range effectively. The composite-PCW could decrease 4.74% of the yearly heating energy consumption compared with the reference wall. The optimization described can provide useful information and guidance for the energy saving of intermittently heated buildings.


Author(s):  
Ritu Garg ◽  
Neha Shukla

Cloud computing makes utility computing possible with pay as you go model. It virtualizes the systems by polling and sharing the resources, thus we need to handle more than one workflow at the same time. Workflow is the standard to represent compute intensive applications in scientific and engineering domain. Hence, in this article, the authors presented the scheduling heuristic for multiple workflows running parallel in the cloud environment with the aim to reduce the energy consumption as it is one of the major concerns of cloud data centers along with the execution performance. In the proposed approach, first clustering is performed to minimize the energy consumption and execution time during communication corresponding to precedence constraint tasks. Then cluster are scheduled is on the best available energy efficient resources. Finally, DVFS is applied in order to reduce energy consumption further when the nodes are in the idle and communication stage. The simulation has been performed on CloudSim and the results show the reduction in energy consumption by up to 42%.


2020 ◽  
Vol 307 ◽  
pp. 01022
Author(s):  
Gitanjali Thakur ◽  
Mohamad Asalam ◽  
Mohammed El Ganaoui

One of the major environmental threat in the world today is the increased production of plastic and its usage. The inept plastic waste management system with regard to its recycling and energy recovery in the developing countries creates a global threat as a major land and water body pollutant. However, its durability, thermal properties, and chemical resistance make plastics an alternate choice as a building material. This study investigates the use of plastic in concrete mixture with an objective to improve the thermal performance of the building. The shredded plastic fibers from plastic bottles (polyethylene terephthalate, PET) were used as a partial weight replacement (2.5%, 5%, and 7.5%) of coarse aggregate in concrete blocks. The cubes were cast using the Indian standards (IS 456) and the essential tests were performed. Additionally, experiments were designed to investigate the change in the thermal conductivity of the concrete block due to the varying amount of plastic. It was found that the use of PETs affected the compressive strength and also decreased the thermal conductivity of the concrete blocks. The experimental results suggest that PETs can be used in the construction of energy-efficient building to handle the environmental concerns because of its abundance.


2019 ◽  
Vol 111 ◽  
pp. 06045
Author(s):  
Mizuki Niimura ◽  
U Yanagi

Subterranean temperature at a depth of 10 m is almost equal to the average outdoor air temperature of the same area. Therefore, if a building cooling trench is used as an outdoor air duct, outdoor air can be cooled in summer and warmed in winter. This energy-saving technique is often used in Japan. However, since the relative humidity in a cooling trench is high, microbe numbers tend to increase in summer. The present study sought to characterize the microbiome status in the cooling trench of such an office building in Japan. Specifically, we performed a metagenomic analysis in which we analyzed DNA directly upon collection from the environment, without intervening cultivation. The results showed the presence of bacteria of the genera Pseudomonas, Lactobacillus, Nesterenkonia, Staphylococcus, Deinococcus, Acinetobacter, Enhydorobacter, and Corynebacterium. Bacteria of the genera Nesterenkonia, Deinococcus, Enhydorobacter, and Corynebacterium predominated on the surface of the trench. Notably, bacteria of the genus Nesterenkonia constituted >50% of the organisms on the surface of the downstream end of the cooling trench. Principal coordinate analysis was used to compare bacterial inhabitants of outdoor air, indoor air from 2nd- and 3rdfloor offices, and the region downstream of the cooling trench. The results suggested that the microbiome of air in this cooling trench influenced indoor air within the building.