Transient behaviour of axial temperature distribution in post-arc channel after current zero around nozzle throat in flat-type SF6gas-blast quenching chamber

1995 ◽  
Vol 28 (10) ◽  
pp. 2095-2103 ◽  
Author(s):  
Y Tanaka ◽  
Y Yokomizu ◽  
T Matsumura ◽  
Y Kito
Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2760
Author(s):  
Ruiye Li ◽  
Peng Cheng ◽  
Hai Lan ◽  
Weili Li ◽  
David Gerada ◽  
...  

Within large turboalternators, the excessive local temperatures and spatially distributed temperature differences can accelerate the deterioration of electrical insulation as well as lead to deformation of components, which may cause major machine malfunctions. In order to homogenise the stator axial temperature distribution whilst reducing the maximum stator temperature, this paper presents a novel non-uniform radial ventilation ducts design methodology. To reduce the huge computational costs resulting from the large-scale model, the stator is decomposed into several single ventilation duct subsystems (SVDSs) along the axial direction, with each SVDS connected in series with the medium of the air gap flow rate. The calculation of electromagnetic and thermal performances within SVDS are completed by finite element method (FEM) and computational fluid dynamics (CFD), respectively. To improve the optimization efficiency, the radial basis function neural network (RBFNN) model is employed to approximate the finite element analysis, while the novel isometric sampling method (ISM) is designed to trade off the cost and accuracy of the process. It is found that the proposed methodology can provide optimal design schemes of SVDS with uniform axial temperature distribution, and the needed computation cost is markedly reduced. Finally, results based on a 15 MW turboalternator show that the peak temperature can be reduced by 7.3 ∘C (6.4%). The proposed methodology can be applied for the design and optimisation of electromagnetic-thermal coupling of other electrical machines with long axial dimensions.


Metals ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 393
Author(s):  
Alexander M. Laptev ◽  
Jürgen Hennicke ◽  
Robert Ihl

Spark Plasma Sintering (SPS) is a technology used for fast consolidation of metallic, ceramic, and composite powders. The upscaling of this technology requires a reduction in energy consumption and homogenization of temperature in compacts. The application of Carbon Fiber-Reinforced Carbon (CFRC) insulating plates between the sintering setup and the electrodes is frequently considered as a measure to attain these goals. However, the efficiency of such a practice remains largely unexplored so far. In the present paper, the impact of CFRC plates on required power, total sintering energy, and temperature distribution was investigated by experiments and by Finite Element Modeling (FEM). The study was performed at a temperature of 1000 °C with a graphite dummy mimicking an SPS setup. A rather moderate influence of CFRC plates on power and energy demand was found. Furthermore, the cooling stage becomes considerably longer. However, the application of CFRC plates leads to a significant reduction in the axial temperature gradient. The comparative analysis of experimental and modeling results showed the good capability of the FEM method for prediction of temperature distribution and required electric current. However, a discrepancy between measured and calculated voltage and power was found. This issue must be further investigated, considering the influence of AC harmonics in the DC field.


2021 ◽  
Vol 141 (11) ◽  
pp. 712-717
Author(s):  
Akira Daibo ◽  
Yoshimitsu Niwa ◽  
Naoki Asari ◽  
Wataru Sakaguchi ◽  
Yo Sasaki ◽  
...  

1961 ◽  
Vol 83 (4) ◽  
pp. 423-431 ◽  
Author(s):  
W. O. Doggett ◽  
E. L. Arnold

Analytic temperature distributions are obtained for the fuel and coolant regions of a heterogeneous, convection-cooled reactor with axial power variation ewt sin (πz/H). The fundamental assumption in the governing differential equations is that the temperature distribution in the fuel region does not vary in the direction transverse to the coolant flow. The solutions involve two and three-parameter integrals encountered and numerically evaluated previously which are integrated herein and arranged in a form suitable for desk calculations. Closed-form expressions are developed for the final steady-state axial distributions which are applicable at times long in comparison with the characteristic temperature-response times.


Author(s):  
He Peng ◽  
Ning Xu ◽  
Zhansheng Liu

Tighten force has much influence on tie-bolt fastened rotor dynamics. Temperature distribution in tie-bolt fastened rotor results in thermal expansion of rotor and rods. The difference of thermal expansion between rotor and rods causes the variation of bolt load. With considering the thermal contact conductance, the thermal model of tie-bolt fastened rotor was established by finite element method and the axial temperature distribution was obtained. The influences of surface roughness, nominal contact pressure and axial position of contact on axial temperature distribution were analysed. Based on temperature distribution in the tie-bolt fastened rotor, the variation of tighten force was investigated. Results show that nominal contact pressure, surface roughness and axial contact arrange have different influences on the variation of tighten force with temperature.


Sign in / Sign up

Export Citation Format

Share Document