Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates

2016 ◽  
Vol 61 (14) ◽  
pp. N349-N361 ◽  
Author(s):  
P Fournier ◽  
J C Crosbie ◽  
I Cornelius ◽  
P Berkvens ◽  
M Donzelli ◽  
...  
1969 ◽  
Vol 42 (494) ◽  
pp. 102-107 ◽  
Author(s):  
Roger J. Berry ◽  
Eric J. Hall ◽  
David W. Forster ◽  
Thomas H. Storr ◽  
Michael J. Goodman
Keyword(s):  
X Rays ◽  

Cancers ◽  
2021 ◽  
Vol 13 (19) ◽  
pp. 4942
Author(s):  
Maria Grazia Ronga ◽  
Marco Cavallone ◽  
Annalisa Patriarca ◽  
Amelia Maia Leite ◽  
Pierre Loap ◽  
...  

The development of innovative approaches that would reduce the sensitivity of healthy tissues to irradiation while maintaining the efficacy of the treatment on the tumor is of crucial importance for the progress of the efficacy of radiotherapy. Recent methodological developments and innovations, such as scanned beams, ultra-high dose rates, and very high-energy electrons, which may be simultaneously available on new accelerators, would allow for possible radiobiological advantages of very short pulses of ultra-high dose rate (FLASH) therapy for radiation therapy to be considered. In particular, very high-energy electron (VHEE) radiotherapy, in the energy range of 100 to 250 MeV, first proposed in the 2000s, would be particularly interesting both from a ballistic and biological point of view for the establishment of this new type of irradiation technique. In this review, we examine and summarize the current knowledge on VHEE radiotherapy and provide a synthesis of the studies that have been published on various experimental and simulation works. We will also consider the potential for VHEE therapy to be translated into clinical contexts.


2011 ◽  
Vol 38 (6Part12) ◽  
pp. 3513-3513
Author(s):  
F Araki ◽  
F Yoshiyama ◽  
T Ohno ◽  
K Kakei ◽  
J Wulff

1970 ◽  
Vol 48 (19) ◽  
pp. 3029-3033 ◽  
Author(s):  
C. Willis ◽  
O. A. Miller

Carbon monoxide has been irradiated with single intense pulses from an electron accelerator at a dose rate of ~ 2 × 1027 eV g−1 s−1. The yield of carbon dioxide obtained was G(CO2) = 0.7 ± 0.1 with a very small yield of carbon suboxide, G(C3O2) ≤ 0.02.Addition of propene reduces the carbon dioxide yield to almost zero while addition of propane has no effect. This suggests that propene is acting as an oxygen atom scavenger rather than as a quencher of an excited state of carbon monoxide. However, rate constant data do not support this suggestion and it is concluded that the residual yield of carbon dioxide observed at high dose rates arises from reaction 9[Formula: see text]where CO+ is in an A2Π or B2Σ+ state.


2014 ◽  
Vol 12 (7) ◽  
pp. 774-781 ◽  
Author(s):  
Ioan Călinescu ◽  
Diana Martin ◽  
Daniel Ighigeanu ◽  
Adina Gavrila ◽  
Adrian Trifan ◽  
...  

AbstractElectron beam (EB) irradiation is a useful method to generate stable silver nanoparticles without the interference of inherent impurities generated from chemical reactions. Our experiments were carried out using linear electron beam accelerators with two different EB absorbed dose rates: 2 kGy min−1 and 7–8 kGy s−1, and with different absorbed dose levels. The optimum conditions for silver nanoparticles (AgNPs) generation by radiolysis, or by radiolysis combined with chemical reduction, were established. In order to obtain a good yield for AgNPs synthesized by radiolysis, a high dose rate is required, resulting in a rapid production process. At low absorbed dose rates, the utilization of a stabilization agent is advisable. By modifying the experimental conditions, the ratio between the chemical and radiolytic reduction process can be adjusted, thus it is possible to obtain nanoparticles with tailored characteristics, depending on the desired application.


2021 ◽  
Author(s):  
Alessio Sarti ◽  
Patrizia De Maria ◽  
Battistoni Giuseppe ◽  
Micol De Simoni ◽  
Cinzia Di Felice ◽  
...  

Abstract Prostate cancer is among the most common cancers in men and one of the leading causes of death worldwide. Different therapies are adopted for its treatment and generally radiotherapy with photons (RT) is the preferred solution in almost all cases. Up to now, in addition to photons, only protons have been implemented as alternative radiotherapy. The use of Very High Energy Electron (VHEE) beams (100-200 MeV) has been suggested in literature but the needed accelerators are more demanding, as far as space and cost are concerned, with respect to standard photon devices, with only limited advantages when compared to protons or other heavy ions. In this contribution we investigate how recent developments in electron beam therapy could reshape the landscape of prostate treatments. The VHEE Treatment Planning System obtained combining an accurate Monte Carlo (MC) simulation with a simple modelling of the FLASH effect (healthy tissues sparing at very high dose rates) is compared with conventional RT. The results demonstrate that FLASH therapy with VHEE beams of 70-130 MeV could represent a valid alternative to standard RT allowing a better sparing of the healthy tissues surrounding the tumour, in the framework of an affordable technological development.


Author(s):  
Abida Sultana ◽  
Ahmed Alanazi ◽  
Jintana Meesungnoen ◽  
Jean-Paul Jay-Gerin

Monte Carlo multi-track chemistry simulations were carried out to study the effects of high dose rates on the transient yields of hydronium ions (H<sub>3</sub>O<sup>+</sup>) formed during low linear energy transfer (LET) radiolysis of both pure, deaerated and aerated liquid water at 25 °C, in the interval ~1 ps–10 μs. Our simulation model consisted of randomly irradiating water with <i>N</i> interactive tracks of 300-MeV incident protons (LET ~ 0.3 keV/μm), which simultaneously impact perpendicularly on the water within a circular surface. The effect of the dose rate was studied by varying <i>N</i>. Our calculations showed that the radiolytic formation of H<sub>3</sub>O<sup>+</sup> causes the entire irradiated volume to temporarily become very acidic. The magnitude and duration of this abrupt “acid-spike” response depend on the value of <i>N</i>. It is most intense at times less than ~10–100 ns, equal to ~3.4 and 2.8 for <i>N</i> = 500 and 2000 (<i>i.e.</i>, for dose rates of ~1.9 × 10<sup>9</sup> and 8.7 × 10<sup>9</sup> Gy/s, respectively). At longer times, the pH gradually increases for all <i>N</i> values and eventually returns to the neutral value of seven, which corresponds to the non-radiolytic, pre-irradiation concentration of H<sub>3</sub>O<sup>+</sup>. It is worth noting that these early acidic pH responses are very little dependent on the presence or absence of oxygen. Finally, given the importance of pH for many cellular functions, this study suggests that these acidic pH spikes may contribute to the normal tissue-sparing effect of FLASH radiotherapy.


2017 ◽  
Vol 45 (1) ◽  
pp. 429-437 ◽  
Author(s):  
Vaiva Kaveckyte ◽  
Alexandr Malusek ◽  
Hamza Benmakhlouf ◽  
Gudrun Alm Carlsson ◽  
Åsa Carlsson Tedgren

Sign in / Sign up

Export Citation Format

Share Document