scholarly journals Nanoparticles synthesis by electron beam radiolysis

2014 ◽  
Vol 12 (7) ◽  
pp. 774-781 ◽  
Author(s):  
Ioan Călinescu ◽  
Diana Martin ◽  
Daniel Ighigeanu ◽  
Adina Gavrila ◽  
Adrian Trifan ◽  
...  

AbstractElectron beam (EB) irradiation is a useful method to generate stable silver nanoparticles without the interference of inherent impurities generated from chemical reactions. Our experiments were carried out using linear electron beam accelerators with two different EB absorbed dose rates: 2 kGy min−1 and 7–8 kGy s−1, and with different absorbed dose levels. The optimum conditions for silver nanoparticles (AgNPs) generation by radiolysis, or by radiolysis combined with chemical reduction, were established. In order to obtain a good yield for AgNPs synthesized by radiolysis, a high dose rate is required, resulting in a rapid production process. At low absorbed dose rates, the utilization of a stabilization agent is advisable. By modifying the experimental conditions, the ratio between the chemical and radiolytic reduction process can be adjusted, thus it is possible to obtain nanoparticles with tailored characteristics, depending on the desired application.

Polymers ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 3012
Author(s):  
Se Kye Park ◽  
Dong Yun Choi ◽  
Duyoung Choi ◽  
Dong Yun Lee ◽  
Seung Hwa Yoo

In this study, a high-density polyethylene (HDPE)-based carbon fiber-reinforced thermoplastic (CFRTP) was irradiated by an electron-beam. To assess the absorbed dose rate influence on its mechanical properties, the beam energy and absorbed dose were fixed, while the absorbed dose rates were varied. The tensile strength (TS) and Young’s modulus (YM) were evaluated. The irradiated CFRTP TS increased at absorbed dose rates of up to 6.8 kGy/s and decreased at higher rates. YM showed no meaningful differences. For CFRTPs constituents, the carbon fiber (CF) TS gradually increased, while the HDPE TS decreased slightly as the absorbed dose rates increased. The OH intermolecular bond was strongly developed in irradiated CFRTP at low absorbed dose rates and gradually declined when increasing those rates. X-ray photoelectron spectroscopy analysis revealed that the oxygen content of irradiated CFRTPs decreased with increasing absorbed dose rate due to the shorter irradiation time at higher dose rates. In conclusion, from the TS viewpoint, opposite effects occurred when increasing the absorbed dose rate: a favorable increase in CF TS and adverse decline of attractive hydrogen bonding interactions between HDPE and CF for CFRTPs TS. Therefore, the irradiated CFRTP TS was maximized at an optimum absorbed dose rate of 6.8 kGy/s.


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2326
Author(s):  
Entesar Ali Ganash ◽  
Reem Mohammad Altuwirqi

In this work, silver nanoparticles (Ag NPs) were synthesized using a chemical reduction approach and a pulsed laser fragmentation in liquid (PLFL) technique, simultaneously. A laser wavelength of 532 nm was focused on the as produced Ag NPs, suspended in an Origanum majorana extract solution, with the aim of controlling their size. The effect of liquid medium concentration and irradiation time on the properties of the fabricated NPs was studied. While the X-ray diffraction (XRD) pattern confirmed the existence of Ag NPs, the UV–Vis spectrophotometry showed a significant absorption peak at about 420 nm, which is attributed to the characteristic surface plasmon resonance (SPR) peak of the obtained Ag NPs. By increasing the irradiation time and the Origanum majora extract concentration, the SPR peak shifted toward a shorter wavelength. This shift indicates a reduction in the NPs’ size. The effect of PLFL on size reduction was clearly revealed from the transmission electron microscopy images. The PLFL technique, depending on experimental parameters, reduced the size of the obtained Ag NPs to less than 10 nm. The mean zeta potential of the fabricated Ag NPs was found to be greater than −30 mV, signifying their stability. The Ag NPs were also found to effectively inhibit bacterial activity. The PLFL technique has proved to be a powerful method for controlling the size of NPs when it is simultaneously associated with a chemical reduction process.


Cancers ◽  
2021 ◽  
Vol 13 (19) ◽  
pp. 4942
Author(s):  
Maria Grazia Ronga ◽  
Marco Cavallone ◽  
Annalisa Patriarca ◽  
Amelia Maia Leite ◽  
Pierre Loap ◽  
...  

The development of innovative approaches that would reduce the sensitivity of healthy tissues to irradiation while maintaining the efficacy of the treatment on the tumor is of crucial importance for the progress of the efficacy of radiotherapy. Recent methodological developments and innovations, such as scanned beams, ultra-high dose rates, and very high-energy electrons, which may be simultaneously available on new accelerators, would allow for possible radiobiological advantages of very short pulses of ultra-high dose rate (FLASH) therapy for radiation therapy to be considered. In particular, very high-energy electron (VHEE) radiotherapy, in the energy range of 100 to 250 MeV, first proposed in the 2000s, would be particularly interesting both from a ballistic and biological point of view for the establishment of this new type of irradiation technique. In this review, we examine and summarize the current knowledge on VHEE radiotherapy and provide a synthesis of the studies that have been published on various experimental and simulation works. We will also consider the potential for VHEE therapy to be translated into clinical contexts.


2011 ◽  
Vol 38 (6Part12) ◽  
pp. 3513-3513
Author(s):  
F Araki ◽  
F Yoshiyama ◽  
T Ohno ◽  
K Kakei ◽  
J Wulff

Blood ◽  
1994 ◽  
Vol 83 (11) ◽  
pp. 3384-3389 ◽  
Author(s):  
R Storb ◽  
RF Raff ◽  
FR Appelbaum ◽  
HJ Deeg ◽  
TC Graham ◽  
...  

Abstract We explored in dogs the immunosuppressive properties of 450 cGy total body irradiation (TBI) delivered from two opposing 60Co sources, as assessed by the criterion of successful engraftment of allogeneic genotypically DLA-identical littermate marrow. Two questions were asked in this study. Firstly, does dose rate affect the immunosuppressive effect of TBI when administered in a single dose? Secondly, does fractionation alter the immunosuppression of TBI when delivered at a very fast dose rate? Dose rates studied included 7 and 70 cGy/min, and fractionation involved four fractions of 112.5 cGy each, with 6-hour minimum interfraction intervals. Six of 7 dogs receiving 450 cGy single- dose TBI at 70 cGy/min showed sustained engraftment of the allogeneic marrow, compared with 1 of 7 dogs receiving single-dose TBI at 7 cGy/min (P = .01). Fractionated TBI at 70 cGy/min resulted in sustained allogeneic engraftment in 3 of 10 dogs, a result that was statistically significantly worse than that with single-dose TBI at 70 cGy/min (P = .03) and not statistically different (P = .24) from that with fractionated TBI delivered at 7 cGy/min (0 of 5 dogs engrafted). A single dose of 450 cGy of TBI delivered at a rate of 70 cGy/min is significantly more immunosuppressive than the same total dose delivered at 7 cGy/min. Fractionated TBI at 70 cGy/min is significantly less immunosuppressive than single-dose TBI at 70 cGy/min and not significantly different from fractionated TBI administered at 7 cGy/min. Results are consistent with the notion that significant DNA repair in lymphoid cells is possible during interfraction intervals at the relatively high dose rate of 70 cGy/min.


Sign in / Sign up

Export Citation Format

Share Document