Total Ionizing Dose Response of Different Length Devices in 0.13 μm Partially Depleted Silicon-on-Insulator Technology

2017 ◽  
Vol 34 (8) ◽  
pp. 088501 ◽  
Author(s):  
Meng-Ying Zhang ◽  
Zhi-Yuan Hu ◽  
Zheng-Xuan Zhang ◽  
Shuang Fan ◽  
Li-Hua Dai ◽  
...  
2014 ◽  
Vol 54 (9-10) ◽  
pp. 2339-2343 ◽  
Author(s):  
Kenneth Potter ◽  
Katrina Morgan ◽  
Chris Shaw ◽  
Peter Ashburn ◽  
William Redman-White ◽  
...  

Author(s):  
A. De Veirman ◽  
J. Van Landuyt ◽  
K.J. Reeson ◽  
R. Gwilliam ◽  
C. Jeynes ◽  
...  

In analogy to the formation of SIMOX (Separation by IMplanted OXygen) material which is presently the most promising silicon-on-insulator technology, high-dose ion implantation of cobalt in silicon is used to synthesise buried CoSi2 layers. So far, for high-dose ion implantation of Co in Si, only formation of CoSi2 is reported. In this paper it will be shown that CoSi inclusions occur when the stoichiometric Co concentration is exceeded at the peak of the Co distribution. 350 keV Co+ ions are implanted into (001) Si wafers to doses of 2, 4 and 7×l017 per cm2. During the implantation the wafer is kept at ≈ 550°C, using beam heating. The subsequent annealing treatment was performed in a conventional nitrogen flow furnace at 1000°C for 5 to 30 minutes (FA) or in a dual graphite strip annealer where isochronal 5s anneals at temperatures between 800°C and 1200°C (RTA) were performed. The implanted samples have been studied by means of Rutherford Backscattering Spectroscopy (RBS) and cross-section Transmission Electron Microscopy (XTEM).


Author(s):  
M. Gaillardin ◽  
C. Marcandella ◽  
M. Martinez ◽  
O. Duhamel ◽  
T. Lagutere ◽  
...  

2018 ◽  
Vol 86 (7) ◽  
pp. 199-206 ◽  
Author(s):  
Ömür Işıl Aydin ◽  
Judson Robert Holt ◽  
Cyrille Le Royer ◽  
Laks Vanamurthy ◽  
Thomas Feudel ◽  
...  

Proceedings ◽  
2020 ◽  
Vol 60 (1) ◽  
pp. 50
Author(s):  
Vladimir Generalov ◽  
Olga Naumova ◽  
Dmitry Shcherbakov ◽  
Alexander Safatov ◽  
Boris Zaitsev ◽  
...  

The presented results indicate virus-like particles of the coronavirus (CVP) using a nanowire (NW) biosensor based on silicon-on-insulator technology. In the experiment, we used suspensions of CVP and of specific antibodies to the virus. Measurements of the current value of the field-effect transistor before and after the introduction of the CVP on the surface of the nanowire were performed. Results showed antibody + CVP complexes on the phase section with the surface of the nanowire modulate the current of the field-effect transistor; CVP has an electrically positive charge on the phase section “nanowire surface-viral suspension»; antibody + CVP complexes have an electrically negative charge on the phase section “nanowire surface-viral suspension”; the sensitivity of the biosensor is made up of 10−18 M; the time display was 200–300 s.


Sign in / Sign up

Export Citation Format

Share Document