scholarly journals Correlation between cooling power and heat quantity of Er-Ho binary nitride as regenerator of 4K-GM cryocooler

2021 ◽  
Vol 1857 (1) ◽  
pp. 012009
Author(s):  
S Arita ◽  
K Takahashi ◽  
T Shiraishi ◽  
S Fujieda ◽  
T Nakagawa ◽  
...  
Keyword(s):  
Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2703
Author(s):  
Robert Sekret ◽  
Przemysław Starzec

The paper presents the investigation of a prototype cold accumulator using water–ice latent heat for the cold storage process. The concept of the cold accumulator was based on a 200-L-capacity cylindrical storage tank in which spherical capsules filled with water were placed. Beds of polypropylene capsules with diameters of 80 mm, 70 mm, and 60 mm were used in the tests. The cold accumulator operated with a water–air heat pump. Based on the test results, the following parameters were calculated: the cooling capacity, cooling power, energy efficiency of the cold storage, and energy efficiency ratio (EER) of the accumulator. The obtained measurement results were described with mathematical relationships (allowing for measurement error) using criterial numbers and the developed “Research Stand Factor Number” (RSFN) index. It has been found that, for the prototype cold accumulator under investigation, the maximum values of the cooling capacity (17 kWh or 85.3 kWh per cubic meter of the accumulator), energy efficiency (0.99), and EER (4.8) occur for an RSFN of 144·10−4. The optimal conditions for the operation of the prototype cold accumulator were the closest to laboratory tests conducted for a bed with capsules with a diameter of 70 mm and a mass flow of the water–glycol mixture flowing between the accumulator and the heat pump of 0.084 kg/s. During the tests, no significant problems with the operation of the prototype cold accumulator were found.


2020 ◽  
Vol 29 (9) ◽  
pp. 1260-1276
Author(s):  
Zili Yang ◽  
Lu-An Chen ◽  
Ruiyang Tao ◽  
Ke Zhong

Liquid desiccant dehumidifiers (LDDs) can be improved by adding internal cooling. However, the addition of excessive cooling power may deteriorate the system‘s cost-efficiency, whereas the addition of insufficient cooling power leads to negligible performance improvements. The objective of this study is to determine the suitable cost-efficient cooling power range for improving the performance of internally cooled LDDs (IC-LDDs). A novel method and a set of criteria related to the moisture removal rate, cooling-power efficiency ( ηc) and coefficient of dehumidification performance from cooling power ( DCOPcooling) were proposed to determine cost-efficient cooling power. The internally cooled ultrasonic atomization liquid desiccant system (IC-UADS), together with a well-validated model based on the conservation laws of mass and energy and the sensible heat balance, was adopted to demonstrate the analysis. The results showed that, although the dehumidification performance improves with increasing cooling power, the improvement rate decreases, while ηcand DCOPcoolingdecline quickly (by 87.9%). For cost-efficient improvement, the necessary power proportion of internal cooling to the system‘s target dehumidification capacity tends to be stable, which was about 29% for the IC-UADS, and independent of the operating conditions. The results may help to determine the reasonable cooling power range for cost-efficient improvement of IC-LDDs.


2020 ◽  
Vol 15 (3) ◽  
Author(s):  
Afshar Alihosseini

AbstractCurrently, air separation units (ASUs) have become very important in various industries, particularly oil and petrochemical industries which provide feed and utility services (oxygen, nitrogen, etc.). In this study, a new industrial ASU was evaluated by collecting operational and process information needed by the simulator by means of HYSYS software (ASPEN-ONE). The results obtained from this simulator were analyzed by ASU data and its error rate was calculated. In this research, the simulation of ASU performance was done in the presence of an expansion turbine in order to provide pressure inside the air distillation tower. Likewise, the cooling capacity of the cooling compartment and the data were analysed. The results indicated that expansion turbine is costly effective. Notably, it not only reduces the energy needed to compress air and supply power of the equipment, but also provides more cooling power and reduces air temperature. Moreover, turbines also increase the concentration of lighter gas products, namely nitrogen.


Cryogenics ◽  
1971 ◽  
Vol 11 (1) ◽  
pp. 39-46 ◽  
Author(s):  
G.J Ehnholm ◽  
R.G Gylling

Sign in / Sign up

Export Citation Format

Share Document