scholarly journals Demonstration and Optimization of Floor Height of 220kV GIS Room in the Indoor Substation

2021 ◽  
Vol 2108 (1) ◽  
pp. 012027
Author(s):  
Yan Li ◽  
Peng Wu ◽  
Lin Xing ◽  
Ning Wang ◽  
Rong Cheng ◽  
...  

Abstract With the development of cities, the construction of indoor substations and the use of gas insulated switchgear (GIS equipment) are becoming more and more widespread. In this paper, the height of 220kVGIS room in the indoor substation is demonstrated and optimized. On the basis of the collection and analysis of the basic data of each major equipment manufacturer, the height of GIS room is analysed from the expansion, maintenance needs and pressure test, which are two limiting factors. Finally, the optimal height of 220kVGIS room is determined.

Author(s):  
K. Cowden ◽  
B. Giammara ◽  
T. Devine ◽  
J. Hanker

Plaster of Paris (calcium sulfate hemihydrate, CaSO4. ½ H2O) has been used as a biomedical implant material since 1892. One of the primary limiting factors of these implants is their mechanical properties. These materials have low compressive and tensile strengths when compared to normal bone. These are important limiting factors where large biomechanical forces exist. Previous work has suggested that sterilization techniques could affect the implant’s strength. A study of plaster of Paris implant mechanical and physical properties to find optimum sterilization techniques therefore, could lead to a significant increase in their application and promise for future use as hard tissue prosthetic materials.USG Medical Grade Calcium Sulfate Hemihydrate Types A, A-1 and B, were sterilized by dry heat and by gamma radiation. Types A and B were additionally sterilized with and without the setting agent potassium sulfate (K2SO4). The plaster mixtures were then moistened with a minimum amount of water and formed into disks (.339 in. diameter x .053 in. deep) in polyethylene molds with a microspatula. After drying, the disks were fractured with a Stokes Hardness Tester. The compressive strengths of the disks were obtained directly from the hardness tester. Values for the maximum tensile strengths σo were then calculated: where (P = applied compression, D = disk diameter, and t = disk thickness). Plaster disks (types A and B) that contained no setting agent showed a significant loss in strength with either dry heat or gamma radiation sterilization. Those that contained potassium sulfate (K2SO4) did not show a significant loss in strength with either sterilization technique. In all comparisons (with and without K2SO4 and with either dry heat or gamma radiation sterilization) the type B plaster had higher compressive and tensile strengths than that of the type A plaster. The type A-1 plaster however, which is specially modified for accelerated setting, was comparable to that of type B with K2SO4 in both compressive and tensile strength (Table 1).


Author(s):  
J.D. Geller ◽  
C.R. Herrington

The minimum magnification for which an image can be acquired is determined by the design and implementation of the electron optical column and the scanning and display electronics. It is also a function of the working distance and, possibly, the accelerating voltage. For secondary and backscattered electron images there are usually no other limiting factors. However, for x-ray maps there are further considerations. The energy-dispersive x-ray spectrometers (EDS) have a much larger solid angle of detection that for WDS. They also do not suffer from Bragg’s Law focusing effects which limit the angular range and focusing distance from the diffracting crystal. In practical terms EDS maps can be acquired at the lowest magnification of the SEM, assuming the collimator does not cutoff the x-ray signal. For WDS the focusing properties of the crystal limits the angular range of acceptance of the incident x-radiation. The range is dependent upon the 2d spacing of the crystal, with the acceptance angle increasing with 2d spacing. The natural line width of the x-ray also plays a role. For the metal layered crystals used to diffract soft x-rays, such as Be - O, the minimum magnification is approximately 100X. In the worst case, for the LEF crystal which diffracts Ti - Zn, ˜1000X is the minimum.


Author(s):  
Umi Halimatus Saidah ◽  
Aang Fatihul Islam

The scenes in the trailer shown are all sorts of interesting and prominent scenesto attract the attention of potential viewers and be able to describe the entire contents of the movie without giving too much information. The trailer was created to promote theatrical release of the movie and the movie trailer was a clip containing all the parts of the advertised movie, shown before other movie screenings in the cinema, and aimed for the audience to come to watch. The best way to teach English is to use interesting material, appropriate teaching methods, the use of technology that can be one of the important and effective support tools. Meta-analysis is essentially a synthesis of a topic taken from several research reports. Based on the synthesis is drawn conclusions about the topic under study. This research uses some similar research results as basic data in conducting studies and conclusions. From the same five studies, it is concluded that Movie Trailer is effective as a learning medium because it can improve understanding in English learning.


2020 ◽  
Vol 140 (5) ◽  
pp. 409-414
Author(s):  
Masaru Tatemi ◽  
Hisao Inami ◽  
Toshiaki Rokunohe ◽  
Makoto Hirose

2012 ◽  
Vol 40 (1) ◽  
pp. 25-41 ◽  
Author(s):  
H. M. R. Aboutorabi ◽  
L. Kung

Abstract REFERENCE: H. M. R. Aboutorabi and L. Kung, “Application of Coupled Structural Acoustic Analysis and Sensitivity Calculations to a Tire Noise Problem,” Tire Science and Technology, TSTCA, Vol. 40, No. 1, January – March 2012, pp. 25–41. ABSTRACT: Tire qualification for an original equipment (OE) program consists of several rounds of submissions by the tire manufacturer for evaluation by the vehicle manufacturer. Tires are evaluated both subjectively, where the tire performance is rated by an expert driver, and objectively, where sensors and testing instruments are used to measure the tire performance. At the end of each round of testing the evaluation results are shared and requirements for performance improvement for the next round are communicated with the tire manufacturer. As building and testing is both expensive and time consuming predictive modeling and simulation analysis that can be applied to the performance of the tire is of great interest and value. This paper presents an application of finite element analysis (FEA) modeling along with experimental verification to solve tire noise objections at certain frequencies raised by an original equipment manufacturer (OEM) account. Coupled structural-acoustic analysis method was used to find modal characteristics of the tire at the objectionable frequencies. Sensitivity calculations were then carried out to evaluate the strength of contribution from each tire component to the identified modes. Based on these findings changes to the construction were proposed and implemented that addressed the noise issue.


Sign in / Sign up

Export Citation Format

Share Document