Counter-rotating type axial flow pump unit in turbine mode for micro grid system

2012 ◽  
Vol 15 (4) ◽  
pp. 042026 ◽  
Author(s):  
R Kasahara ◽  
G Takano ◽  
T Murakami ◽  
T Kanemoto ◽  
K Komaki
2016 ◽  
Vol 99 ◽  
pp. 1146-1152 ◽  
Author(s):  
Zhongdong Qian ◽  
Fan Wang ◽  
Zhiwei Guo ◽  
Jie Lu

2021 ◽  
Vol 9 ◽  
Author(s):  
Xiaohui Duan ◽  
Fangpin Tang ◽  
Hao Xu ◽  
Jian Chen ◽  
Qun Lu ◽  
...  

The hydraulic excitation characteristics of axial flow pump unit are studied through theoretical analysis, numerical simulation and field test in this paper. The correlation between impeller hydraulic and radial vibration displacement of impeller centroid is obtained through theoretical analysis. Through the 1-way fluid-solid-interaction (FSI) numerical simulation, the distributions of water pressure and displacement on the impeller surface are obtained, and the time-domain and frequency-domain characteristics of transient hydraulic and radial displacement are revealed. Through the field test, the external characteristics of axial flow pump unit and the time-frequency characteristics of the pressure pulsation at the measuring points beside the inlet of the impeller are obtained. The comparisons between simulation results and experimental results show that the former is accurate and reliable.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3053
Author(s):  
Youn-Sung Kim ◽  
Man-Woong Heo ◽  
Hyeon-Seok Shim ◽  
Bong-Soo Lee ◽  
Dong-Hwan Kim ◽  
...  

Submersible pumps are now in high demand due to the sporadic occurrence of recent torrential rains. The current study was carried out to investigate the hydraulic characteristics of a submersible axial-flow pump with a swept impeller and to optimize the impeller and diffuser shapes of the pump to enhance the hydraulic performance. Three-dimensional Reynolds-averaged Navier–Stokes equations were solved with the shear stress transport turbulence model. The governing equations were discretized using the finite volume method, and unstructured tetrahedral and hexahedral meshes were used in the grid system. The optimal grid system was selected through a grid dependency test. A performance test for the submersible axial-flow pump was carried out experimentally, and the results of the numerical analysis were validated against the experimental results. The hydraulic efficiency and the total head were used as objective functions. For the first optimization, a multi-objective optimization was carried out to simultaneously improve the objective functions through a hybrid multi-objective evolutionary algorithm coupled with a response surface approximation by varying the swept angle and pitch angle of the blades of the rotating impeller. The second multi-objective optimization was performed using two design variables, i.e., the inlet angle and the length of the diffuser vanes, to simultaneously increase the objective functions. Clustered optimum designs in the Pareto optimal solutions yielded significant increases in the objective function values as compared with the reference design.


Author(s):  
Tengen Murakami ◽  
Toshiaki Kanemoto ◽  
Gohki Takano ◽  
Risa Kasahara

Pumped storage system contributes to adjust the electric power unbalance between day and night, in general. The pumping operation, however, may be unstable in the rising portion of the head characteristics, and/or bring the cavitation at the low suction head. To simultaneously overcome both weak points, the authors have proposed a superior pumping unit that is composed of counter-rotating type impellers and a peculiar motor with double rotational armatures. This paper discusses the operation at the turbine mode of the above unit. It is concluded with the numerical simulations that this type unit can be also operated acceptably at the turbine mode, because the unit works so as to coincide the angular momentum change through the front runners/impellers with that thorough the rear runners/impellers, namely to take the axial flow at not only the inlet but also the outlet without the guide vanes.


2021 ◽  
Vol 11 (15) ◽  
pp. 6774
Author(s):  
Fan Yang ◽  
Dongjin Jiang ◽  
Tieli Wang ◽  
Pengcheng Chang ◽  
Chao Liu ◽  
...  

The outlet conduit is an important construction connecting the outlet of the pump guide vane and the outlet pool; in order to study the hydraulic performance of the straight outlet conduit of the axial-flow pump device, this paper adopts the method of numerical simulation and analyzes the influence of the division pier on the pressure and velocity distribution inside and near the wall of the straight outlet conduit based on three design schemes. Four pressure pulsation measuring points were arranged in the straight outlet conduit, and the low-frequency pulsation characteristic information inside the straight outlet conduit with and without the division pier was extracted by wavelet packet reconstruction. The results show that the addition of a division pier has an effect on the hydraulic loss, near-wall pressure and velocity distribution in the straight outlet conduit. A small high-pressure zone is formed near the wall at the starting position of the division pier, and a large high-speed zone is formed on the left side at the starting position of the division pier. The length of the division pier has no significant effect on the flow distribution of the straight outlet conduit and the pressure and velocity distribution near the wall. Under different working conditions, each monitoring point has the maximum energy in the sub-band (0~31.25 Hz). With the increase of the flow rate, the total pressure energy of the straight outlet conduit decreases gradually. Under each condition, the difference of the energy proportion of the horizontal monitoring points of the straight outlet conduit is small, and the difference of the energy proportion of the two monitoring points at the top and bottom of the outlet channel is relatively large. The energy of the two monitoring points in the straight outlet conduit with a division pier is smaller than that of the two monitoring points in the straight outlet conduit without a division pier. There are differences in the main frequency and the power spectrum corresponding to the main frequency of the monitoring points in the straight outlet conduit, and the reasonable setting of the division pier is conducive to reducing the pressure pulsation of the flow in the straight outlet conduit and is beneficial to the safe and stable operation of the pump device.


Perfusion ◽  
1998 ◽  
Vol 13 (2) ◽  
pp. 111-117 ◽  
Author(s):  
Joseph J Sistino

One of the most controversial and challenging surgical undertakings of the next century promises to be foetal cardiac surgery. Animal studies have been underway for several years to gain an understanding of the physiological mechanisms required to achieve this undertaking. Not since the days of crosscirculation has there been a maternal risk associated with open-heart surgery. The diagnosis of congenital heart defects with foetal ultrasound can now be made as early as 12 weeks gestation. Simple cardiac abnormalities, such as valvular stenosis or atresia, alter intracardiac flow patterns and affect normal cardiac chamber development. Without early intervention, these complex lesions often require major surgical reconstruction, beginning in the neonatal period. Foetal cardiac bypass techniques have evolved from the use of roller pumps and bubble oxygenators primed with maternal blood to the use of an axial flow pump incorporated in a right atrial to pulmonary artery or aortic shunt. Because the blood entering the right atrium is oxygenated by the placenta, an oxygenator in the bypass circuit is probably not needed. The low prime axial flow pump system avoids the dilution of the foetus with the maternal adult haemoglobin and improves the outcome. A major focus of research has concentrated on maintenance of placental blood flow with the use of vasodilators and cyclooxygenase inhibitors. Investigation with primates will be necessary to confirm the placental physiology before human operations can be performed. As the foetal bypass challenges are overcome, there is the potential for a reduction in the number of complex cardiac lesions requiring early surgical intervention in the twenty-first century.


Author(s):  
Sang-Won Kim ◽  
Youn-Jea Kim

An axial-flow pump has a relatively high discharge flow rate and specific speed at a relatively low head and it consists of an inlet guide vane, impeller, and outlet guide vane. The interaction of the flow through the inlet guide vane, impeller, and outlet guide vane of the axial-flow pump has a significant effect on its performance. Of those components, the guide vanes especially can improve the head and efficiency of the pump by transforming the kinetic energy of the rotating flow, which has a tangential velocity component, into pressure energy. Accordingly, the geometric configurations of the guide vanes such as blade thickness and angle are crucial design factors for determining the performance of the axial-flow pump. As the reliability of Computational Fluid Dynamics (CFD) has been elevated together with the advance in computer technology, numerical analysis using CFD has recently become an alternative to empirical experiment due to its high reliability to measure the flow field. Thus, in this study, 1,200mm axial-flow pump having an inlet guide vane and impeller with 4 blades and an outlet guide vane with 6 blades was numerically investigated. Numerical study was conducted using the commercial CFD code, ANSYS CFX ver. 16.1, in order to elucidate the effect of the thickness and angle of the guide vanes on the performance of 1,200mm axial-flow pump. The stage condition, which averages the fluxes between interfaces and is accordingly appropriate for the evaluation of pump performance, was adopted as the interface condition between the guide vanes and the impeller. The rotational periodicity condition was used in order to enable a simplified geometry to be used since the guide vanes feature multiple identical regions. The shear stress transport (SST) k-ω model, predicting the turbulence within the flow in good agreement, was also employed in the CFD calculation. With regard to the numerical simulation results, the characteristics of the pressure distribution were discussed in detail. The pump performance, which will determine how well an axial-flow pump will work in terms of its efficiency and head, was also discussed in detail, leading to the conclusion on the optimal blade thickness and angle for the improvement of the performance. In addition, the total pressure loss coefficient was considered in order to investigate the loss within the flow paths depending on the thickness and angle variations. The results presented in this study may give guidelines to the numerical analysis of the axial-flow pump and the investigation of the performance for further optimal design of the axial-flow pump.